Skip to main content

previous disabled Page of 4
and
  1. No Access

    Article

    New image-restoration method using a simultaneous algebraic reconstruction technique: comparison with the Richardson–Lucy algorithm

    We developed a new image-restoration method that incorporates the point spread function (PSF) into the simultaneous algebraic reconstruction technique (SART-PSF). Additionally, through simulation studies, we i...

    Kenya Murase in Radiological Physics and Technology (2020)

  2. Article

    Open Access

    Longitudinal observations of progressive cardiac dysfunction in a cardiomyopathic animal model by self-gated cine imaging based on 11.7-T magnetic resonance imaging

    The purpose of this study was to longitudinally assess left ventricular function and wall thickness in a hamster model of cardiomyopathy using 11.7-T magnetic resonance imaging (MRI). MRI were performed for si...

    Shigeyoshi Saito, Minori Tanoue, Kasumi Masuda, Yuki Mori in Scientific Reports (2017)

  3. No Access

    Article

    Differentiation of myocardial ischemia and infarction assessed by dynamic computed tomography perfusion imaging and comparison with cardiac magnetic resonance and single-photon emission computed tomography

    To evaluate the feasibility of myocardial blood flow (MBF) by computed tomography from dynamic CT perfusion (CTP) for detecting myocardial ischemia and infarction assessed by cardiac magnetic resonance (CMR) o...

    Yuki Tanabe, Teruhito Kido, Teruyoshi Uetani, Akira Kurata in European Radiology (2016)

  4. No Access

    Article

    Factors affecting the chemical exchange saturation transfer of Creatine as assessed by 11.7 T MRI

    Chemical exchange saturation transfer (CEST) is a new contrast enhancement approach for imaging exogenous or endogenous substances such as creatine (Cr), amide protons, and glutamate in the human body. An incr...

    Shigeyoshi Saito, Yuki Mori, Nobuyoshi Tanki in Radiological Physics and Technology (2015)

  5. Article

    Open Access

    Radiotherapy treatment planning with contrast-enhanced computed tomography: feasibility of dual-energy virtual unenhanced imaging for improved dose calculations

    In radiotherapy treatment planning, intravenous administration of an iodine-based contrast agent during computed tomography (CT) improves the accuracy of delineating target volumes. However, increased tissue a...

    Sachiko Yamada, Takashi Ueguchi, Toshiyuki Ogata, Hirokazu Mizuno in Radiation Oncology (2014)

  6. No Access

    Article

    Experimental and simulation studies on the behavior of signal harmonics in magnetic particle imaging

    Our purpose in this study was to investigate the behavior of signal harmonics in magnetic particle imaging (MPI) by experimental and simulation studies. In the experimental studies, we made an apparatus for MP...

    Kenya Murase, Takashi Konishi, Yuki Takeuchi in Radiological Physics and Technology (2013)

  7. No Access

    Article

    Three-dimensional topographical variation of femoral cartilage T2 in healthy volunteer knees

    Quantitative knee cartilage T2 assessment on limited two-dimensional midsagittal or midcoronal planes may be insufficient to assess variations in normal cartilage composition. The purpose of this work was to r...

    Toshiyuki Shiomi, Takashi Nishii, Ken Nakata, Satoru Tamura in Skeletal Radiology (2013)

  8. No Access

    Article

    An empirical mathematical model applied to quantitative evaluation of thioacetamide-induced acute liver injury in rats by use of dynamic contrast-enhanced computed tomography

    Our purpose in this study was to apply an empirical mathematical model (EMM) to the quantitative evaluation of thioacetamide (TAA)-induced acute liver injury in rats by use of dynamic contrast-enhanced compute...

    Kenya Murase, Shuichiro Kobayashi, Akihiro Kitamura in Radiological Physics and Technology (2013)

  9. No Access

    Article

    Visualization of mouse spinal cord microscopic structures by use of ex vivo quantitative micro-CT images

    Histologic methods are destructive and provide only two-dimensional images, whereas three-dimensional information is difficult to obtain. Simple and noninvasive techniques to make up for the shortcomings of hi...

    Shigeyoshi Saito, Kenya Murase in Radiological Physics and Technology (2013)

  10. No Access

    Article

    Usefulness of extent analysis for statistical parametric map** with asymmetry index using inter-ictal FGD-PET in mesial temporal lobe epilepsy

    Inter-ictal 18F-2-fluoro-deoxy-d-glucose-positron emission tomography (FDG-PET) is widely used for preoperative evaluation to identify epileptogenic zones in patients with temporal lobe epilepsy. In this study, w...

    Tsutomu Soma, Toshimitsu Momose, Miwako Takahashi in Annals of Nuclear Medicine (2012)

  11. No Access

    Article

    Usefulness of a dual-input single-compartment model for quantitative evaluation of thioacetamide-induced acute liver injury in rats using dynamic contrast-enhanced computed tomography

    We undertook this study to investigate the usefulness of a dual-input single-compartment model for evaluating thioacetamide (TAA)-induced acute liver injury in rats by use of dynamic contrast-enhanced computed...

    Shuichiro Kobayashi, Akihiro Kitamura in Radiological Physics and Technology (2012)

  12. No Access

    Article

    Investigation of protective effect of hydrogen-rich water against cisplatininduced nephrotoxicity in rats using blood oxygenation level-dependent magnetic resonance imaging

    The aim of this study was to assess the mechanism of the protective effect of hydrogen-rich water (HW) against cisplatin (CP)-induced nephrotoxicity in rats using blood oxygenation level-dependent (BOLD) magne...

    Taro Matsushita, Yoshinori Kusakabe, Akihiro Kitamura in Japanese Journal of Radiology (2011)

  13. No Access

    Article

    Simulation and experimental studies on magnetic hyperthermia with use of superparamagnetic iron oxide nanoparticles

    Our purpose of this study was to present simulation and experimental studies on magnetic hyperthermia (MH) with use of an alternating magnetic field (AMF) and superparamagnetic iron oxide nanoparticles (Resovist®

    Kenya Murase, Junko Oonoki, Hiroshige Takata in Radiological Physics and Technology (2011)

  14. No Access

    Article

    Variation in supratentorial cerebrospinal fluid production rate in one day: measurement by nontriggered phase-contrast magnetic resonance imaging

    Measuring the cerebrospinal fluid (CSF) production rate is important for understanding the physiology related to normal conditions and neurological disorders. Triggered phase-contrast magnetic resonance imagin...

    Hiroto Takahashi, Hisashi Tanaka, Norihiko Fujita in Japanese Journal of Radiology (2011)

  15. No Access

    Article

    Investigation of optimal viewing size for detecting nodular ground-glass opacity on high-resolution computed tomography with cine-mode display

    We evaluated the effect of the displayed image sizes on observers’ ability to detect nodular ground-glass opacity (n-GGO) on CT and investigated the optimal viewing size for soft-copy reading at CT screening f...

    Michihiro Yamaguchi, Yuichi Bessho, Tatsuro Inoue in Radiological Physics and Technology (2011)

  16. No Access

    Article

    Improvement of image resolution of brain SPECT by use of the wide-angle offset acquisition method

    Cerebral SPECT images require high spatial and contrast resolution for precise evaluation of the abnormal tracer distribution in the brain. A shorter data acquisition time is preferable so that artifacts due t...

    Yasuyuki Takahashi, Noboru Oriuchi, Hiroshi Higashino in Annals of Nuclear Medicine (2011)

  17. No Access

    Article

    Measurement of manganese content in various organs in rats with or without glucose stimulation

    Our purpose in this study was to assess the manganese (Mn) content in various organs in rats with or without glucose stimulation in vivo and in vitro by using magnetic resonance imaging (MRI) and polarized Zee...

    Mamoru Nagata, Toshio Kagawa, Daichi Koutou in Radiological Physics and Technology (2011)

  18. No Access

    Article

    Peri-infarct dysfunction in post-myocardial infarction: assessment of 3-T tagged and late enhancement MRI

    To determine LV function at different distances from myocardial infarction (MI) by using 3-T tagged MRI and late gadolinium enhancement (LGE).

    Yuma Inoue, **aomei Yang, Michinobu Nagao, Hiroshi Higashino in European Radiology (2010)

  19. No Access

    Article

    Experimental verification of age-dependent cisplatin-induced nephrotoxicity in rats using dynamic contrast-enhanced computed tomography

    The aim of this study was to investigate age-dependent cisplatin-induced nephrotoxicity in rats using dynamic contrast-enhanced computed tomography (DCE-CT).

    Atsushi Tachibana, Ayumu Nagasawa, Akihiro Kitamura in Japanese Journal of Radiology (2010)

  20. No Access

    Article

    Patient setup verification procedure for a portal image in a computed radiography system with a high-resolution liquid-crystal display monitor

    In our conventional visual inspection for setup verification, we have routinely used a console monitor of a CR system and a monitor of a treatment-planning system (i.e., the separate-monitor method) in order t...

    Hideki Fujita, Michihiro Yamaguchi, Yuichi Bessho in Radiological Physics and Technology (2010)

previous disabled Page of 4