Log in

Measurement of manganese content in various organs in rats with or without glucose stimulation

  • Published:
Radiological Physics and Technology Aims and scope Submit manuscript

Abstract

Our purpose in this study was to assess the manganese (Mn) content in various organs in rats with or without glucose stimulation in vivo and in vitro by using magnetic resonance imaging (MRI) and polarized Zeeman atomic absorption spectrophotometry (PZAAS), respectively. MRI studies were performed in 12 rats using a 1.5-T MRI system. The rats were injected intravenously with saline (6 ml/kg) (saline-stimulated group, n = 6) or glucose (2.34 g/kg) (glucose-stimulated group, n = 6). Ten minutes after saline or glucose administration, MnCl2 (0.02 mmol/kg) was injected intravenously, followed by 6 MRI studies at 8-min intervals. After the last MRI study, rats were killed, and the Mn concentrations in various organs were measured using PZAAS. There was a discrepancy between in vivo and in vitro measurements, which appeared to be due to the partial volume effect and/or the contribution of extracellular Mn. The Mn concentration in the pancreas, normalized to that in the liver in the glucose-stimulated group, increased significantly compared to that in the saline-stimulated group, suggesting that the influx of Mn into β cells in the pancreas increased in response to glucose stimulation. This study suggested that the measurement of the change in the Mn concentration due to glucose stimulation using PZAAS was effective for evaluating β-cell function in the pancreas.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
EUR 32.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or Ebook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price includes VAT (Germany)

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. Meiri U, Rahamimoff R. Neuromuscular transmission: inhibition by manganese ions. Science. 1972;176:308–9.

    Article  CAS  PubMed  Google Scholar 

  2. Hunter DR, Komai H, Haworth RA, Jackson MD, Berkoff HA. Comparison of Ca2+, Sr2+, and Mn2+ fluxes in mitochondria of the perfused rat heart. Circ Res. 1980;47:721–7.

    CAS  PubMed  Google Scholar 

  3. Lin YJ, Koretsky AP. Manganese ion enhances T1-weighted MRI during brain activation: an approach to direct imaging of brain function. Magn Reson Med. 1997;38:378–88.

    Article  CAS  PubMed  Google Scholar 

  4. Silva AC, Lee JH, Aoki I, Koretsky AP. Manganese-enhanced magnetic resonance imaging (MEMRI): methodological and practical considerations. NMR Biomed. 2004;17:532–43.

    Article  CAS  PubMed  Google Scholar 

  5. Yu X, Wadghiri YZ, Sanes DH, Turnbull DH. In vivo auditory brain map** in mice with Mn-enhanced MRI. Nat Neurosci. 2005;8:961–8.

    CAS  PubMed  Google Scholar 

  6. Aoki I, Wu YJ, Silva AC, Lynch RM, Koretsky AP. In vivo detection of neuroarchitecture in the rodent brain using manganese-enhanced MRI. NeuroImage. 2004;22:1046–59.

    Article  PubMed  Google Scholar 

  7. Watanabe T, Natt O, Boretius S, Frahm J, Michaelis T. In vivo 3D MRI staining of mouse brain after subcutaneous application of MnCl2. Magn Reson Med. 2002;48:852–9.

    Article  PubMed  Google Scholar 

  8. Antkowiak PF, Tersey SA, Carter JD, Vandsburger MH, Nadler JL, Epstein FH, Mirmira RG. Noninvasive assessment of pancreatic β-cell function in vivo with manganese-enhanced magnetic resonance imaging. Am J Physiol Endocrinol Metab. 2009;296:E573–8.

    Article  CAS  PubMed  Google Scholar 

  9. Dryselius S, Grapengiesser E, Hellman B, Gylfe E. Voltage-dependent entry and generation of slow Ca2+ oscillations in glucose-stimulated pancreatic beta-cells. Am J Physiol. 1999;276:E512–8.

    CAS  PubMed  Google Scholar 

  10. Gimi B, Leoni L, Oberholzer J, Braun M, Avila J, Wang Y, Desai T, Philipson LH, Magin RL, Roman BB. Functional MR microimaging of pancreatic β-cell activation. Cell Transplant. 2006;15:195–203.

    Article  PubMed  Google Scholar 

  11. Koizumi H, Yasuda K, Katayama M. Atomic absorption spectrophotometry based on the polarization characteristics of the Zeeman effect. Anal Chem. 1977;49:1106–12.

    Article  CAS  Google Scholar 

  12. Ni Y, Petre C, Bosmans H, Miao Y, Grant D, Baert AL, Marchal G. Comparison of manganese biodistribution and MR contrast enhancement in rats after intravenous injection of MnDPDP and MnCl2. Acta Radiol. 1997;38:700–7.

    CAS  PubMed  Google Scholar 

  13. Moore A. Advances in beta-cell imaging. Eur J Radiol. 2009;70:254–7.

    Article  PubMed  Google Scholar 

Download references

Acknowledgments

The authors thank the editors and reviewers who spent a great deal of time and gave us informative advice for improving our manuscript.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Kenya Murase.

About this article

Cite this article

Nagata, M., Kagawa, T., Koutou, D. et al. Measurement of manganese content in various organs in rats with or without glucose stimulation. Radiol Phys Technol 4, 7–12 (2011). https://doi.org/10.1007/s12194-010-0098-6

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12194-010-0098-6

Keywords

Navigation