![Loading...](https://link.springer.com/static/c4a417b97a76cc2980e3c25e2271af3129e08bbe/images/pdf-preview/spacer.gif)
-
Article
Open AccessLarge variation in radiation dose for routine abdomen CT: reasons for excess and easy tips for reduction
To characterize the use and impact of radiation dose reduction techniques in actual practice for routine abdomen CT.
-
Article
Dose length product to effective dose coefficients in adults
The most accurate method for estimating patient effective dose (a principal metric for tracking patient radiation exposure) from computed tomography (CT) requires time-intensive Monte Carlo simulation. A simpl...
-
Article
Open AccessCT acquisition parameter selection in the real world: impacts on radiation dose and variation amongst 155 institutions
Quantify the relationship between CT acquisition parameters and radiation dose, how often parameters are adjusted in real-world practice, and their degree of contribution to real-world dose distribution. Ident...
-
Article
Open AccessCorrection to: Dose length product to effective dose coefficients in children
-
Article
Open AccessDose length product to effective dose coefficients in children
The most accurate method for estimating effective dose (the most widely understood metric for tracking patient radiation exposure) from computed tomography (CT) requires time-intensive Monte Carlo simulation. ...
-
Article
Quantifying cancer risk from exposures to medical imaging in the Risk of Pediatric and Adolescent Cancer Associated with Medical Imaging (RIC) Study: research methods and cohort profile
The Risk of Pediatric and Adolescent Cancer Associated with Medical Imaging (RIC) Study is quantifying the association between cumulative radiation exposure from fetal and/or childhood medical imaging and subs...
-
Article
Open AccessReference phantom selection in pediatric computed tomography using data from a large, multicenter registry
Radiation dose metrics vary by the calibration reference phantom used to report doses. By convention, 16-cm diameter cylindrical polymethyl-methacyrlate phantoms are used for head imaging and 32-cm diameter ph...
-
Article
Open AccessDiagnostic reference levels and median doses for common clinical indications of CT: findings from an international registry
The European Society of Radiology identified 10 common indications for computed tomography (CT) as part of the European Study on Clinical Diagnostic Reference Levels (DRLs, EUCLID), to help standardize radiati...
-
Article
CT Radiation and the Risk of Cancer
The paper covers three points. First, the doses we use for CT are higher than widely reported and are higher than what is needed for diagnosis and should be reduced. Second, these doses are in the range where ...
-
Article
Trends of CT Utilization in North America Over the Last Decade
Given the improvements in technology and usefulness of CT for diagnosis and therapeutic-planning, the growth in CT utilization is not surprising. Current estimates are that more than 85 million CT scans are pe...