Chapter
Radiation risks and patient issues
The centennial year of Roentgen’s discovery of X-rays (1995), and Becquerel’s discovery of radioactivity (1996), are important historical markers for radiation medicine. We have just lived through the 50th ann...
-
Article
Studies of aluminum in rat brain
The effects of high aluminum concentrations in rat brain were studied using14C autoradiography to measure the uptake of [14C]2deoxy-d-glucose ([14C]2dG) and microbeam proteon-induced X-ray emission (microPIXE) wi...
-
Chapter
The development of radioiodinated 3-methyl-branched fatty acids for evaluation of myocardial disease by single photon techniques
The measurement of regional myocardial “release-rates” after intravenous administration of iodine-123-labeled fatty acids such as 17-iodoheptadecanoic acid (HDA) [1–6] and 15-(p-iodophenyl)pentadecanoic acid (...
-
Chapter
Adaptive Frequency-Domain Filtering Of Dynamic Scintigraphies
The predominant role of amplitude/phase analysis in parametric imaging of radionuclide ventriculographies has emphasised the importance of including both time and motion variables in the description of cardiac...
-
Chapter
Coded Aperture Tomography Revisited
If the goal of Nuclear Medicine is to quantify the distribution of a radio labelled pharmaceutical inside an organ, then the two major drawbacks of the gamma camera when used with parallel hole collimators (th...
-
Article
97Ru-transferrin uptake in tumor and abscess
The uptake of97Ru-transferrin (Ru-TF) in tumor and abscess bearing animals was compared with67Ga-citrate (Ga),123I-transferrin (I-TF), and several other plasma proteins. Maximal concentration in tumor of Ru-TF in...
-
Chapter and Conference Paper
2-D Fitting and Interpolation Applied to Image Distortion Analysis
Most imaging devices induce geometric (spatial) distortions of images (1). In other words, every point is mislocated from its true location to an imaged location, depending on the distortion characteristics of...
-
Article
Book review
-
Chapter
Film Analysis Systems and Applications
Quantitative film analysis systems are being used successfully in high technology applications, including earth’s surface map**, aerial reconnaissance, and high energy physics particle tracking. The intense ...
-
Article
The effect of diphenylhydantoin (Dilantin) on thallium-201 chloride uptake
The effect of diphenylhydantoin (Dilantin) on the myocardial uptake of 201Tl-chloride was studied in rats. Prior administration of Dilantin caused a significant (38.8) decrease in 201Tl uptake compared with the c...
-
Chapter
Maternal-Fetal Transport of Iron and Iodine in Human Subjects
Information on the absorption, distribution and metabolism of normal body constituents as well as drugs, and toxic materials in man is difficult to obtain. The development of tracer techniques has made it poss...