![Loading...](https://link.springer.com/static/c4a417b97a76cc2980e3c25e2271af3129e08bbe/images/pdf-preview/spacer.gif)
-
Article
Open AccessVerarbeitungseigenschaften und Viskositäten von PMMA-Knochenzementen
Verarbeitungseigenschaften von PMMA-Knochenzementen können in vier Phasen unterteilt werden: 1. Anmischung, 2. Wartephase, 3. Verarbeitungsphase sowie 4. Aushärtephase. Jede dieser Phasen unterliegt einer Reih...
-
Article
Laser engravings as reason for mechanical failure of titanium-alloyed total hip stems
Two revisions of broken β-titanium total hip stems had to be performed in our hospital after 2 and 4 years in situ. Since both fractures were located at the level of a laser engraving, a failure analysis was c...
-
Article
How stiffness and distal interlocking of revision hip stems influence the femoral cortical strain pattern
Stress shielding and nonphysiological load transfer after primary or revision total hip replacement (THR) prepare the ground for resorptive bone remodeling. The quality of the bone stock influences the risk of...
-
Article
Tissue engineering of the anterior cruciate ligament: a new method using acellularized tendon allografts and autologous fibroblasts
The availability of autogenous tendons (middle part of patellar tendon, semitendinosus/gracilis, or quadriceps tendon) for cruciate ligament reconstructions is restricted and related to withdrawal morbidity. A...
-
Article
Two column lesions in the thoracolumbar junction: anterior, posterior or combined approach? A comparative biomechanical in vitro investigation
There are various surgical techniques for the treatment of spinal fractures in the thoracolumbar region. Several implants have been developed for anterior or posterior instrumentation. Optimal treatment of uns...
-
Article
Biomechanical and immunohistochemical analysis of high hydrostatic pressure-treated Achilles tendons
Reconstruction of bone defects caused by malignant tumors is carried out in different ways. At present, tumor-bearing bone segments are devitalized mainly by extracorporeal irradiation or autoclaving, but both...
-
Article
Pitfalls in the use of acetabular reinforcement rings in total hip revision
Introduction: For the reconstruction of acetabular bone defects different types of acetabular reinforcement rings are being used. In clinical practice, these implants showed to some exten...
-
Article
Is a single anterolateral screw-plate fixation sufficient for the treatment of spinal fractures in the thoracolumbar junction? A Biomechanical in vitro Investigation
Controversy exists about the indications, advantages and disadvantages of various surgical techniques used for anterior interbody fusion of spinal fractures in the thoracolumbar junction. The purpose of this s...
-
Article
Differences between the wear couples metal-on-polyethylene and ceramic-on-ceramic in the stability against dislocation of total hip replacement
After total hip replacement an insufficient range of motion (ROM) can lead to contact between femoral neck and rim of the cup (=im**ement) causing dislocation and consecutive material failure. The purpose of...