![Loading...](https://link.springer.com/static/c4a417b97a76cc2980e3c25e2271af3129e08bbe/images/pdf-preview/spacer.gif)
300 Result(s)
-
Article
Open AccessMinute ventilation sensor–driven rate response as a part of cardiac resynchronization therapy optimization in older patients
Chronotropic incompetence (CI) is common among elderly cardiac resynchronization therapy pacemaker (CRT-P) patients on optimal medical therapy. This study aimed to evaluate the impact of optimized rate-adaptiv...
-
Article
Open AccessProcedural efficiency is enhanced combining the pentaspline pulsed field ablation catheter with three-dimensional electroanatomical map** system for pulmonary vein isolation
Pulsed field ablation (PFA) offers a safe, non-thermal alternative for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). Currently, the pentaspline PFA-system relies heavily on fluorosc...
-
Article
Open AccessDenki buro: a Japanese electric bath in public space causing inappropriate ICD shock
-
Article
Open AccessSex-specific outcomes and left atrial remodeling following catheter ablation of persistent atrial fibrillation: results from the DECAAF II trial
Catheter ablation is recognized as an effective treatment for atrial fibrillation (AF). Despite its effectiveness, significant sex-specific differences have been observed, which influence the outcomes of the p...
-
Article
Open AccessTowards continuous optimization of CRT settings: the relationship between pulmonary artery dP/dt and Left ventricular dP/dt measurements
-
Article
Open AccessTwo decades of SVT ablation in Denmark: a trend towards higher age, more comorbidity, and less prior use of antiarrhythmic and rate-limiting pharmacotherapy—a nationwide registry-based Danish study
Trends in patient selection and use of pharmacotherapy prior to catheter ablation (CA) for supraventricular tachycardia (SVT) are not well described. This study examined temporal trends in patients undergoing ...
-
Article
Open AccessComputed tomography–based device-sizing in Amplatzer Amulet left atrial appendage occlusion
Amplatzer Amulet is a frequently used device for left atrial appendage occlusion (LAAO). The current sizing protocol is based on the maximum diameter of the left atrial appendage (LAA) landing zone. However, m...
-
Article
Open AccessEbstein’s anomaly: an electrophysiological perspective
Ebstein’s anomaly of the tricuspid valve (EA) is an uncommon congenital cardiac malformation. It can present with atrioventricular tachycardia (AVRT), atrioventricular nodal re-entrant tachycardia (AVNRT), atr...
-
Article
Open AccessPulsed field ablation in patients with cardiac implantable electronic devices: an ex vivo assessment of safety
Pulse field ablation (PFA) is a novel catheter ablation technology with potential safety benefits due to its tissue selectivity. It has the potential to directly damage or interact with the functionality of ca...
-
Article
Open AccessThe characterization of functional conduction block in patients with multiple types of atrial tachycardia- A discussion on the mechanism of multiple atrial tachycardia
High-resolution map** offers superior accuracy in delineating conduction features; however, certain characteristics are still linked to elevated recurrence rates of atrial tachycardia (AT), suggesting the in...
-
Article
Open AccessOmitting transesophageal echocardiography before catheter ablation of atrial fibrillation
Data about necessity of performing transesophageal echocardiography (TOE) prior to every catheter ablation (CA) of atrial fibrillation (AF) is scarce. We aimed to evaluate the safety of an individualized risk-...
-
Article
Open AccessImplantation of a novel insertable cardiac monitor: preliminary multicenter experience in Europe
The LUX-Dx™ is a novel insertable cardiac monitor (ICM) introduced into the European market since October 2022.
-
Article
Open AccessValidation of a prediction model for early reconnection after cryoballoon ablation
We previously developed an early reconnection/dormant conduction (ERC) prediction model for cryoballoon ablation to avoid a 30-min waiting period with adenosine infusion. We now aimed to validate this model ba...
-
Article
Open AccessTherapeutic potential of conduction system pacing as a method for improving cardiac output during ventricular tachycardia
Ventricular tachycardia (VT) reduces cardiac output through high heart rates, loss of atrioventricular synchrony, and loss of ventricular synchrony. We studied the contribution of each mechanism and explored t...
-
Article
Open AccessThree-year incidence of pacemaker implantation in patients with atrial fibrillation and sinus node dysfunction receiving ablation versus antiarrhythmic drugs
Sinus node dysfunction (SND) is commonly seen in patients with atrial fibrillation (AF). The purpose of this study was to compare the incidence of pacemaker implantation among patients with SND and AF treated ...
-
Article
Open AccessPressure waveform analysis for occlusion assessment significantly reduces contrast medium use in cryoballoon pulmonary vein isolation
Pulmonary vein (PV) occlusion is crucial for adequate lesion formation during cryoballoon-guided pulmonary vein isolation (CB-PVI). PV occlusion is usually confirmed by angiographies over the inflated balloon ...
-
Article
Open AccessStrategy to achieve mitral isthmus flutter ablation by radiofrequency: the SHERIFF plan
Achieving mitral isthmus (MI) block can be challenging. This prospective study evaluated the feasibility and efficacy of a systematic strategy comprising three consecutive steps to achieve MI block.
-
Article
Open AccessThe impact of ultrasound-guided vascular access for catheter ablation of left atrial arrhythmias in a high-volume centre
Vascular complications are a common occurrence during atrial fibrillation ablation. Observational studies indicate that the utilization of ultrasound (US)-guided puncture may decrease the incidence of vascular...
-
Article
Open AccessSafety and acute performance of atrial fibrillation ablation using a temperature-controlled, very high-power short-duration catheter and a new radiofrequency generator
-
Article
Open AccessComparison of voltages between atria: differences in sinus rhythm and atrial fibrillation
Ultra high-density map** systems allow for comparison of atrial electroanatomical maps in unprecedented detail. Atrial scar determined by voltages and surface area between atria, rhythm and atrial fibrillati...