Skip to main content

and
  1. No Access

    Article

    Studying the spectrometric characteristics of an ionizing-radiation detector based on a LaBr3(Ce) scintillator and a silicon photomultiplier

    The intrinsic background of a LaBr3(Ce) scintillator with a diameter of 5 mm and a height of 10 mm has been studied in comparison with LYSO and CeBr3 scintillators. It is shown that due to its high energy resolut...

    A. K. Berdnikova, F. A. Dubinin, V. V. Dmitrenko in Instruments and Experimental Techniques (2017)

  2. No Access

    Article

    The RED-100 two-phase emission detector

    The RED-100 experimental setup, which is designed to detect elastic coherent neutrino scattering off xenon nuclei, is described. One specific feature of this setup is the possibility of using it in above groun...

    D. Yu. Akimov, I. S. Aleksandrov, V. A. Belov in Instruments and Experimental Techniques (2017)

  3. No Access

    Article

    Thermal stabilization system for the RED-100 liquid-xenon emission detector

    The thermal stabilization system for the RED-100 liquid-xenon two-phase emission detector has been designed and tested. The RED-100 detector is developed by the Russian Emission Detectors (RED) collaboration f...

    V. V. Ananiev, A. I. Bolozdynya, K. F. Vlasik in Instruments and Experimental Techniques (2015)

  4. No Access

    Article

    A transition radiation detector based on thin inorganic scintillators

    The possibility of designing a prototype of the scintillation transition radiation detector (Sci-TRD) based on a thin (∼200 μm) inorganic scintillator has been investigated. Vacuum and silicon photomultipliers...

    V. V. Berdnikov, Yu. B. Gurov, B. A. Dolgoshein in Instruments and Experimental Techniques (2013)

  5. No Access

    Article

    Detection of neutrons and γ rays by a xenon pulsed ionization chamber

    The applicability of a xenon γ-ray spectrometer based on a high-pressure (50 atm) xenon cylindrical ionization chamber to thermal neutron detection is discussed. The reaction of radiative capture of thermal ne...

    V. V. Dmitrenko, K. F. Vlasik, V. M. Grachev in Instruments and Experimental Techniques (2012)

  6. No Access

    Article

    A scintillation response and an ionization yield in pure xenon and mixtures of it with methane

    The scintillation response to an α source (241Am) and the ionization yield in pure gaseous xenon and its mixtures with 0.2–2% of methane were measured at a pressure of 26 atm and different values of reduced elect...

    K. N. Pushkin, N. Hasebe, C. Tezuka in Instruments and Experimental Techniques (2006)

  7. No Access

    Article

    An Automatic Data-Processing Technique for the High-Pressure Xenon γ-Ray Spectrometer

    We describe an algorithm for radionuclide detection and identification by the γ-ray spectra recorded with a high-pressure xenon γ-ray spectrometer. The algorithm is based on the comparison of the measured spec...

    K. F. Vlasik, V. M. Grachev, V. V. Dmitrenko in Instruments and Experimental Techniques (2000)