Skip to main content

and
  1. No Access

    Article

    Electron Noise Generated by Cosmic Muons in the RED-100 Two-Phase Xenon Emission Detector

    It is shown that the working volume of the RED-100 two-phase emission detector, which operates in a ground-based laboratory with liquid xenon used as a working substance, is a source of single-electron noise s...

    D. Yu. Akimov, I. S. Aleksandrov, V. A. Belov in Instruments and Experimental Techniques (2023)

  2. No Access

    Article

    A Setup for Studying Electroluminescence in Gaseous Xenon

    A laboratory experimental setup based on an electroluminescent chamber with gaseous xenon at room temperature and a pressure of 6 atm is described. It is used in the educational process to study electrolumines...

    D. Yu. Akimov, A. I. Bolozdynya in Instruments and Experimental Techniques (2022)

  3. Article

    Open Access

    Erratum to: The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs

    D. S. Akerib, C. W. Akerlof, D. Yu. Akimov in The European Physical Journal C (2022)

  4. No Access

    Article

    A Passive Shield for the RED-100 Neutrino Detector

    A combined passive shield of the RED-100 two-phase emission neutrino detector has been developed and built for suppressing the background of external γ rays and neutrons. The shield is composed of a 5‑cm-thick...

    D. Yu. Akimov, I. S. Aleksandrov, V. A. Belov in Instruments and Experimental Techniques (2021)

  5. Article

    Open Access

    The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs

    LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $${1.4 \t...

    D. S. Akerib, C. W. Akerlof, D. Yu. Akimov in The European Physical Journal C (2020)

  6. No Access

    Article

    An Integral Method for Processing Xenon Used as a Working Medium in the RED-100 Two-Phase Emission Detector

    An integral method is described for processing xenon used as a working medium in the RED-100 two-phase emission detector constructed in the NRNU MEPhI to study the process of elastic coherent neutrino scatteri...

    D. Yu. Akimov, V. A. Belov, A. I. Bolozdynya in Instruments and Experimental Techniques (2019)

  7. No Access

    Article

    Synthesis of Titanium Nanoparticles in Liquid Xenon by a High-Voltage Discharge

    The formation of titanium nanoparticles (NPs) in a high-voltage electric discharge between titanium electrodes in liquid xenon at a temperature of –105°C has been observed. It has been shown that these titaniu...

    D. Yu. Akimov, V. A. Belov, S. V. Bobkov, A. I. Bolozdynya in Technical Physics Letters (2018)

  8. No Access

    Article

    Purification of liquid xenon with the spark discharge technique for use in two-phase emission detectors

    A procedure for spark-discharge purification of a liquid xenon sample with a mass of 55 kg is described. The average lifetime of ionization electrons before capture by electronegative impurities in liquid xeno...

    D. Yu. Akimov, V. A. Belov, A. K. Berdnikova in Instruments and Experimental Techniques (2017)

  9. No Access

    Article

    The RED-100 two-phase emission detector

    The RED-100 experimental setup, which is designed to detect elastic coherent neutrino scattering off xenon nuclei, is described. One specific feature of this setup is the possibility of using it in above groun...

    D. Yu. Akimov, I. S. Aleksandrov, V. A. Belov in Instruments and Experimental Techniques (2017)

  10. No Access

    Article

    Thermostatting of the RED-100 liquid-xenon emission detector

    The thermal stabilization system of the RED-100 liquid-xenon two-phase emission detector for the experiment aimed at detecting the effect of coherent neutrino scattering off xenon nuclei has been tested. The s...

    A. I. Bolozdynya, Yu. V. Efremenko in Instruments and Experimental Techniques (2016)

  11. No Access

    Article

    The digital trigger system for the RED-100 detector

    The system for forming a trigger for the liquid xenon detector RED-100 is developed. The trigger can be generated for all types of events that the detector needs for calibration and data acquisition, including...

    P. P. Naumov, D. Yu. Akimov, V. A. Belov, A. I. Bolozdynya in Physics of Atomic Nuclei (2015)

  12. No Access

    Article

    Thermal stabilization system for the RED-100 liquid-xenon emission detector

    The thermal stabilization system for the RED-100 liquid-xenon two-phase emission detector has been designed and tested. The RED-100 detector is developed by the Russian Emission Detectors (RED) collaboration f...

    V. V. Ananiev, A. I. Bolozdynya, K. F. Vlasik in Instruments and Experimental Techniques (2015)

  13. No Access

    Article

    Noise characteristics of low-background Hamamatsu R11410-20 photomultiplier tubes

    The RED-100 two-phase liquid xenon emission detector is developed today for the experiment aimed at searching for elastic coherent neutrino scattering off atomic nuclei. The main elements of the photodetector ...

    D. Yu. Akimov, A. I. Bolozdynya in Instruments and Experimental Techniques (2015)

  14. No Access

    Article

    A γ probe for radionuclide diagnostics of cancer

    A miniature γ probe for nuclear medicine based on a LaBr3:Ce scintillation crystal and a silicon photomultiplier is described. The γ ray detection efficiency is 29% for 137Cs (662 keV) and 70% for 57Co (122 keV)....

    A. I. Bolozdynya, K. A. Vorobiev in Instruments and Experimental Techniques (2015)

  15. No Access

    Article

    Recording of relativistic particles in thin scintillators

    Results of investigating an assembly of thin scintillators and silicon photomultipliers for registering relativistic particles with the minimum ionization are presented. A high efficiency of registering relati...

    I. A. Tolstukhin, A. S. Somov, S. V. Somov in Instruments and Experimental Techniques (2014)

  16. No Access

    Article

    A controllable voltage divider for Hamamatsu R11410-20 photomultipliers for use in the RED 100 emission detector

    A control circuit for the operation of Hamamatsu R11410-20 photomultiplier tubes (PMTs), which is intended for use in the RED 100 liquid-xenon emission detector, was developed. To prevent the photocathode degr...

    D. Yu. Akimov, A. I. Bolozdynya in Instruments and Experimental Techniques (2014)

  17. No Access

    Article

    Measurement of single-electron noise in a liquid-xenon emission detector

    A technique for studying single-electron noise in emission detectors that are intended for detection of rare processes with small energy releases is developed. Examples of possible applications are experiments...

    D. Yu. Akimov, I. S. Aleksandrov, V. A. Belov in Instruments and Experimental Techniques (2012)

  18. No Access

    Article

    Measuring the85Kr content in krypton using a liquid ionization chamber

    S. N. Anisimov, A. S. Barabash, A. I. Bolozdynya, V. N. Stekhanov in Soviet Atomic Energy (1989)