Skip to main content

previous disabled Page of 2
and
  1. No Access

    Chapter and Conference Paper

    Size and Shape of Spherical Objects on Full-Field Digital Mammography and Digital Breast Tomosynthesis Images

    This study assessed the accuracy of shape and size representation of spherical objects on full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT) images. Six 5-mm-thick polymethylmethacryl...

    Hidetoshi Yatake, Yuka Sawai in World Congress on Medical Physics and Biom… (2019)

  2. No Access

    Chapter and Conference Paper

    Temporal Characterization of the Flat-Bed Scanner Influencing Dosimetry Using Radiochromic Film

    Radiochromic films (RFs) have been developed for the measurement of the absorbed dose of low-energy photons. RFs are self-develo** and radiation sensitive, and the amount of darkening is proportional to the ...

    Rumi Gotanda, Toshizo Katsuda in World Congress on Medical Physics and Biom… (2019)

  3. No Access

    Chapter and Conference Paper

    Optimal Variable Refocus Flip Angle Control Method and Echo Train Length for Suppressing Exposure to Radio Frequency

    The popularization of 3-Tesla magnetic resonance imaging (MRI) has improved the quality of images and shortened typical examination times. However, a side effect of this is increased exposure to radio frequenc...

    Akihiko Tabuchi, Shinichi Arao in World Congress on Medical Physics and Biom… (2019)

  4. No Access

    Chapter and Conference Paper

    Influence of Image Resolution Property on Aliasing Error of Digital Wiener Spectrum

    The noise properties of a radiography system are commonly described by its wiener spectrum (WS). The two-dimensional discrete Fourier transform (2D-DFT) methods is the most commonly used and accepted technique...

    Yasuyuki Kawaji, Tatsuhiro Gotanda in World Congress on Medical Physics and Biom… (2019)

  5. No Access

    Chapter and Conference Paper

    Evaluation of Effective Energy Distribution of 320-Multidetector CT Using GAFCHROMIC EBT3

    Knowledge of the effective energy of 320-multidetector computed tomography (CT) is important for quality assurance and quality control. Evaluation in two dimensions is necessary because the effective energy va...

    Tatsuhiro Gotanda, Toshizo Katsuda in World Congress on Medical Physics and Biom… (2019)

  6. No Access

    Chapter and Conference Paper

    Basic research on countermeasures against barium sulfate aggregation using a gastric phantom

    The principal aim of this study was to conduct basic experiments to examine countermeasures against barium sulfate aggregation caused by denture adhesive in gastric cancer screening test. Experiment 1; barium ...

    Kenyu Yamamoto, Naoko Fujiwara, Yoshihiro Takeda, Rena Takakura in EMBEC & NBC 2017 (2018)

  7. No Access

    Chapter and Conference Paper

    Ultraviolet Ray Strength for Pre-irradiation in Gafchromic EBT2

    Ultraviolet (UV) rays strength and density change of Gafchromic EBT2 were investigated. It has previously been suggested that UV rays can be used as a substitute for the X-ray double-irradiation technique to c...

    Toshizo Katsuda, Rumi Gotanda, Tatsuhiro Gotanda, Takuya Akagawa in EMBEC & NBC 2017 (2018)

  8. No Access

    Chapter and Conference Paper

    Influence of scattered radiation on Gafchromic EBT3

    Gafchromic EBT3 (EBT3) is used as a radiochromic film in half-value layer (HVL) measurement methods, which are used to calculate the effective energy for QA and QC. HVL measurements using EBT3 display a precis...

    Tatsuhiro Gotanda, Toshizo Katsuda, Ayano Kawasaki, Rumi Gotanda in EMBEC & NBC 2017 (2018)

  9. No Access

    Chapter and Conference Paper

    UV Intensity of Pre-irradiation in Gafchromic XR-RV3 and XR-SP2

    UV-A irradiation of Gafchromic XR-RV3 and XR-SP2 are considered to be a substitute for X-ray irradiation in the double irradiation of Gafchromic XR-RV3 and XR-SP2. It makes it possible to compensate for hetero...

    Tadao Kuwano, Yoshihiro Takeda, Toshizo Katsuda, Rumi Gotanda in EMBEC & NBC 2017 (2018)

  10. No Access

    Article

    Accuracy assessment methods of tissue marker clip placement after 11-gauge vacuum-assisted stereotactic breast biopsy: comparison of measurements using direct and conventional methods

    The objective of the study was to compare direct measurement with a conventional method for evaluation of clip placement in stereotactic vacuum-assisted breast biopsy (ST-VAB) and to evaluate the accuracy of c...

    Hidetoshi Yatake, Yuka Sawai, Toshio Nishi, Yoshiaki Nakano in Breast Cancer (2017)

  11. No Access

    Chapter

    Understanding Medical Images Based on Computational Anatomy Models

    This chapter presents examples of medical image understanding algorithms using computational anatomy models explained in Chap. 2. After the introductory in Sect. 3.1, Se...

    Shouhei Hanaoka, Naoki Kamiya in Computational Anatomy Based on Whole Body … (2017)

  12. No Access

    Chapter and Conference Paper

    Evaluation of Scanner Image Properties of Radiochromic Film for Measuring Effective Energy

    The effective energy calculated using the half-value layer (HVL) is an important parameter for quality assurance (QA) and quality control (QC). However constant monitoring has not been performed because measur...

    Tatsuhiro Gotanda, Toshizo Katsuda in 6th European Conference of the Internation… (2015)

  13. No Access

    Chapter and Conference Paper

    Evaluation of Dose Distribution According to Patient Setup Errors in Pediatric Head CT Examination: A Phantom Study

    Radiation doses during computed tomography (CT) examinations are generally evaluated by CT dose index (CTDI). The CTDI is measured by means of a CTDI phantom, which is placed in the center of the CT gantry ape...

    Rumi Gotanda, Yoshihiro Takeda in 6th European Conference of the Internation… (2015)

  14. No Access

    Article

    Effectiveness of the new injection program ‘saline test injection mode’ for use power injector in pediatric contrast CT

    To improve the safety of the use of a power injector for pediatric contrast CT, we newly developed a saline test injection mode for a power injector and investigated its usefulness. We used an injection route ...

    Shuji Abe, Naoto Mizuno, Shouji Tani in Australasian Physical & Engineering Scienc… (2013)

  15. No Access

    Article

    Evaluation of GAFCHROMIC EBT2 dosimetry for the low dose range using a flat-bed scanner with the reflection mode

    Recently developed radiochromic films can easily be used to measure absorbed doses because they do not need development processing and indicate a density change that depends on the absorbed dose. However, in G...

    Tatsuhiro Gotanda, Toshizo Katsuda in Australasian Physical & Engineering Scienc… (2013)

  16. No Access

    Chapter and Conference Paper

    Effects of Bolus Volume on Geniohyoid Muscle Movement during Swallowing: Ultrasonographic M-Mode Study in Healthy Adults

    Purpose: Videofluoroscopy is generally considered a “gold standard” technique for diagnosing dysphagia; however this technique exposes subjects to radiation. Ultrasonography is applied widely in clinical pract...

    Koichi Yabunaka, Gojiro Nakagami in 5th European Conference of the Internation… (2012)

  17. No Access

    Article

    Predicting sentinel lymph node metastasis in breast cancer with lymphoscintigraphy

    Lymphoscintigraphy is an effective method for detecting sentinel lymph nodes (SLNs). However, the rate and degree of SLN detection is not uniform. We quantified SLNs detected with lymphoscintigraphy, and inves...

    Atsushi Noguchi, Masahisa Onoguchi, Takeshi Ohnishi in Annals of Nuclear Medicine (2011)

  18. No Access

    Article

    Improved detection of gastric cancer during screening by additional radiographs as judged necessary by the radiographer

    The aim of this study was to determine whether additional radiographs, as judged necessary by the radiographer, improves cancer detection during gastric cancer screening.

    Hidetoshi Yatake, Yoshihiro Takeda, Toshizo Katsuda in Japanese Journal of Radiology (2011)

  19. No Access

    Article

    Sonographic assessment of hyoid bone movement during swallowing: a study of normal adults with advancing age

    Our aim in this study was to evaluate hyoid bone movement trajectories and the age-related changes during swallowing in healthy subjects by ultrasonography. Data were obtained from 30 healthy volunteers (15 me...

    Koichi Yabunaka, Hiromi Sanada, Shigeru Sanada in Radiological Physics and Technology (2011)

  20. No Access

    Article

    Film-reading ability of radiographers in detecting gastric cancer during screening using X-ray examination

    The aim of this study was to evaluate the film-reading ability of radiographers in detecting gastric cancer during screening X-ray examinations.

    Hidetoshi Yatake, Yoshihiro Takeda, Toshizo Katsuda in Japanese Journal of Radiology (2009)

previous disabled Page of 2