Skip to main content

and
  1. No Access

    Article

    Preliminary establishment and validation of the inversion method for growth and remodeling parameters of patient-specific abdominal aortic aneurysm

    Traditional medical imaging and biomechanical studies have challenges in analyzing the long-term evolution process of abdominal aortic aneurysm (AAA). The homogenized constrained mixture theory (HCMT) allows f...

    Chen Peng, Wei He, **gyang Luan, Tong Yuan in Biomechanics and Modeling in Mechanobiology (2024)

  2. No Access

    Article

    Morphology Optimization of Leaflet for Surgical Reconstruction of the Aortic Valve: In Vitro Test and Simulation-Based DOE Study

    This study was to evaluate the impact of leaflet trimming strategy on the hemodynamic behaviors of the aortic valve after reconstructive surgery, and give recommendations based on design of experiment (DOE) an...

    Yong Feng, Bowen Zhang, Jianming Li in Journal of Cardiovascular Translational Re… (2023)

  3. No Access

    Article

    Discrimination of intracranial aneurysm rupture status: patient-specific inflow boundary may not be a must-have condition in hemodynamic simulations

    Computational fluid dynamics (CFD) are important in evaluating the hemodynamics of intracranial aneurysm rupture, and the setting of inflow boundary conditions is critical. We evaluated intracranial aneurysm h...

    Wenqiang Li, Shengzhang Wang, Zhongbin Tian, Wei Zhu, Yisen Zhang in Neuroradiology (2020)

  4. Article

    Open Access

    Efficient simulation of a low-profile visualized intraluminal support device: a novel fast virtual stenting technique

    The low-profile visualized intraluminal support (LVIS) stent has become a promising endovascular option for treating intracranial aneurysms. To achieve better treatment of aneurysms using LVIS, we developed a ...

    Qianqian Zhang, Jian Liu, Yisen Zhang, Ying Zhang in Chinese Neurosurgical Journal (2018)

  5. Article

    Open Access

    Phantom-based experimental validation of fast virtual deployment of self-expandable stents for cerebral aneurysms

    Endovascular intervention using a stent is a mainstream treatment for cerebral aneurysms. To assess the effect of intervention strategies on aneurysm hemodynamics, we have developed a fast virtual stenting (FV...

    Qianqian Zhang, Zhuangyuan Meng, Ying Zhang, Kai Yao in BioMedical Engineering OnLine (2016)

  6. Article

    Open Access

    Computational fluid dynamics analysis on recurrence of simple coiling intracranial aneurysms with remnant neck

    Hemodynamic factors are considered to play an important role in the initiation and recurrence of cerebral aneurysms. However, hemodynamic characteristics leading to the recurrence of aneurysms is not well reco...

    **long Yu, Gang Lu, Shengzhang Wang, Lei Huang, Liang Ge in Chinese Neurosurgical Journal (2016)

  7. Article

    Open Access

    Flow diverter effect of LVIS stent on cerebral aneurysm hemodynamics: a comparison with Enterprise stents and the Pipeline device

    The aim of this study was to quantify the effect of the new Low-profile Visualized Intraluminal Support (LVIS®D) device and the difference of fluid diverting effect compared with the Pipeline device and the En...

    Chao Wang, Zhongbin Tian, Jian Liu, Linkai **g in Journal of Translational Medicine (2016)

  8. No Access

    Article

    Hemodynamic Alterations for Various Stent Configurations in Idealized Wide-neck Basilar Tip Aneurysm

    Stent-assisted coiling technology is widely used in the treatment of intracranial aneurysms. However, differences among various stent configurations have not been fully characterized. This study investigates t...

    Chao Wang, Zhongbin Tian, Jian Liu in Journal of Medical and Biological Engineer… (2016)

  9. No Access

    Article

    Hemodynamic alterations after stent implantation in 15 cases of intracranial aneurysm

    Stent-assisted coiling technology has been widely used in the treatment of intracranial aneurysms. In the current study, we investigated the intra-aneurysmal hemodynamic alterations after stent implantation an...

    Chao Wang, Zhongbin Tian, Jian Liu, Linkai **g, Nikhil Paliwal in Acta Neurochirurgica (2016)

  10. Article

    Open Access

    Influence of morphology and hemodynamic factors on rupture of multiple intracranial aneurysms: matched-pairs of ruptured-unruptured aneurysms located unilaterally on the anterior circulation

    The authors evaluated the impact of morphological and hemodynamic factors on the rupture of matched-pairs of ruptured-unruptured intracranial aneurysms on one patient’s ipsilateral anterior circulation with 3D...

    Ying Zhang, **njian Yang, Yang Wang, Jian Liu, Chuanhui Li, Linkai **g in BMC Neurology (2014)

  11. No Access

    Article

    Hemodynamic performance of coil embolization and stentassisted coil embolization treatments: a numerical comparative study based on subject-specific models of cerebral aneurysms

    Hemodynamic characteristics such as blood velocity, blood pressure, flow im**ement, wall shear stress and oscillatory shear index are considered to play important roles in the initiation, growth, rupture and...

    ShengZhang Wang, YiSen Zhang, Gang Lu in Science China Physics, Mechanics and Astro… (2011)

  12. No Access

    Article

    The effect of aneurismal-wall mechanical properties on patient-specific hemodynamic simulations: two clinical case reports

    Hemodynamic factors such as the wall shear stress play an important role in the pathogenesis and treatment of cerebral aneurysms. In present study, we apply computational fluid–structure interaction analyses o...

    Jialiang Chen, Shengzhang Wang, Guanghong Ding, **njian Yang in Acta Mechanica Sinica (2009)

  13. No Access

    Chapter and Conference Paper

    A Lumped Parameters Dynamic Model for Cerebral Circulation

    A lumped parameters dynamic model for cerebral blood circulation is constructed according to the hydrodynamic model, and the simulations prove the validity of this model. Given the values of the parameters and...

    Shengzhang Wang in 7th Asian-Pacific Conference on Medical and Biological Engineering (2008)