  1. Article

    Open Access

    Pt-40%Rh Versus Pt-6%Rh Thermocouples: An emf-Temperature Reference Function for the Temperature Range 0 °C to 1769 °C

    The paper describes the metrological characterization of the highly stable Pt-40%Rh/Pt-6%Rh thermocouples to determine their reference function in the temperature range between 0 °C and 1769 °C. The preparatio...

    Frank Edler, Jovan Bojkovski in International Journal of Thermophysics (2021)

  2. Article

    Open Access

    Species diversity, host preference and arbovirus detection of Culicoides (Diptera: Ceratopogonidae) in south-eastern Serbia

    Culicoides (Diptera: Ceratopogonidae) is a genus of small biting midges (also known as “no-see ums”) that currently includes 1368 described species. They are proven or suspected vectors for important pathogens af...

    Ana Vasić, Nemanja Zdravković, Dragoș Aniță, Jovan Bojkovski in Parasites & Vectors (2019)

  3. No Access

    Article

    Tick infestation and occurrence of Anaplasma phagocytophilum and piroplasms in cattle in the Republic of Serbia

    Ticks transmit important pathogens affecting cattle such as intracellular bacteria of the genus Anaplasma or protozoa of the order Piroplasmida. This study aimed at assessing tick species present on pastures and ...

    Ana Vasić, Marion Nieder, Nemanja Zdravković, Jovan Bojkovski in Parasitology Research (2018)

  4. No Access

    Article

    Inter-laboratory Comparison of Impedance-Type Hygrometer in the Range from 10 % to 95 % at \(5\,^{\circ }\hbox {C}\) to \(55\,^{\circ }\hbox {C}\)

    Traceability in the field of relative humidity (RH) measurements is typically assured indirectly through dew point and temperature scales. Conducting an inter-laboratory comparison at the national metrology in...

    Domen Hudoklin, Regina Mnguni, Hans Liedberg in International Journal of Thermophysics (2014)

  5. No Access

    Article

    Investigation of the Equivalence of National Dew-Point Temperature Realizations in the −50 °C to + 20 °C Range

    In the field of humidity quantities, the first CIPM key comparison, CCT-K6 is at its end. The corresponding European regional key comparison, EUROMET.T-K6, was completed in early 2008, about 4 years after the ...

    Martti Heinonen, Miltiadis Anagnostou in International Journal of Thermophysics (2012)

  6. No Access

    Article

    Genetic characterization and phylogenetic analysis of porcine circovirus type 2 (PCV2) in Serbia

    Porcine circovirus type 2 (PCV2) is the main causative agent of postweaning multisystemic wasting syndrome (PMWS). To characterize and determine the genetic diversity of PCV2 in the porcine population of Serbi...

    Bozidar Savic, Vesna Milicevic, Dobrila Jakic-Dimic in Archives of Virology (2012)

  7. No Access

    Article

    Detection rates of the swine torque teno viruses (TTVs), porcine circovirus type 2 (PCV2) and hepatitis E virus (HEV) in the livers of pigs with hepatitis

    Porcine circovirus type 2 (PCV2) and hepatitis E virus (HEV) are the most recently recognized causes of infectious hepatitis of pigs and may or may not act independently in the development of the disease. Rece...

    Bozidar Savic, Vesna Milicevic, Jovan Bojkovski in Veterinary Research Communications (2010)

  8. No Access

    Article

    Regional cooperation in proficiency testing: strategy planning and practical experiences in Western Balkan countries

    The article describes the project of regional cooperation in proficiency testing within CARDS 2006 (assistance programme to the Western Balkans), which was coordinated by European Committee for Standardization...

    Janko Drnovšek, Igor Pušnik, Jovan Bojkovski in Accreditation and Quality Assurance (2010)

  9. No Access

    Article

    Automation of Resistance Bridge Calibrator

    The article addresses the automation of the resistance bridge calibrator (RBC). The automation of the RBC is performed in order to facilitate the operation of the RBC, improve the reliability, and enable sever...

    Tadej Podgornik, Jovan Bojkovski in International Journal of Thermophysics (2008)

  10. No Access

    Chapter and Conference Paper

    Simple verification of infrared ear thermometers by use of fixed-point

    Due to a number of reasons infrared ear thermometers (IRETs) are becoming very popular in many medical applications, where temperature measurements are important. However, one of the drawbacks of using IRETs i...

    Jovan Bojkovski in 11th Mediterranean Conference on Medical a… (2007)