Evaluation of the Fire Suppression Effectiveness of Manually Applied Compressed-Air-Foam (CAF) System

  • Published:
Fire Technology Aims and scope Submit manuscript

Abstract

Mobile compressed-air-foam (CAF) systems represent a new type of fire suppression system, which is gaining popularity among fire services. Properly engineered CAF systems produce superior quality foam with high momentum. However, until now, there has not been a study to systematically evaluate the fire suppression effectiveness of mobile CAF systems. NRC has carried out a project to evaluate the effectiveness of a mobile CAF system in suppressing fully developed compartment fires. Several full-scale compartment fire tests were conducted to compare the fire suppression performance of a manually applied CAF system with that of hose stream application using water alone and using water-foam solution, under similar conditions. The study showed that a CAF system is much more effective in suppressing the compartment fire compared to hose stream application with water only or with foam-water solution. A CAF system with a 95 L/min (25 GPM) water flow rate suppressed the test fire better than the hose-stream application with water only or with foam-solution using 360 L/min (95 GPM). The CAF system suppressed the fire and cooled down the fire compartment (to 200°C) much quicker than the water alone or foam-solution. Also, the total amount of water used to control the test fire was much less with the CAF system than with the water alone or foam-solution.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
EUR 32.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or Ebook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Figure 7
Figure 8
Figure 9
Figure 10

Similar content being viewed by others

Reference

  • Kim A, Dlugogorski B (1997) Multipurpose overhead compressed-air-foam system and its fire suppression performance. J Fire Protect Eng 8(3):133–150

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Andrew K. Kim.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kim, A.K., Crampton, G.P. Evaluation of the Fire Suppression Effectiveness of Manually Applied Compressed-Air-Foam (CAF) System. Fire Technol 48, 549–564 (2012). https://doi.org/10.1007/s10694-009-0119-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10694-009-0119-3

Keywords

Navigation