    Gamma Correction 99mTc-HDP Pinhole Bone Scan of Callused Trabecular Microfracture in Surgical Specimen: Histological Validation

    CTMF (callused trabecular microfracture) ubiquitously occurs in osteoporosis (Vernon-Roberts and Pirie 1973), contusion (Mandalia and Henson 2008), aseptic osteonecrosis (McFarland and Frost 1961), inflammator...

    Yong-Whee Bahk in Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage (2020)

  2. No Access

    Chapter

    Corroborative Analysis of Callused Trabecular Microfracture on 99mTc-HDP Pinhole Bone Scan, Surgical Specimen, GCPBS, and H&E Stain

    As anticipated the shape and size of trabecular fracture widely vary presenting as pinpoint, speckle, rod-like, archipelagic, geographic, and amorphously crushed tracer uptake. Indeed, some are large and some ...

    Yong-Whee Bahk in Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage (2020)

  3. No Access

    Chapter

    ACDSee-10 Gamma Correction Multidetector Computed Tomographic Demonstration and Quantitation of Callused Trabecular Microfracture

    Computed tomography (CT) consists of an X-ray generator, X-ray detector, and computerized imaging and recording systems. The latest model of multidetector computed tomography (MDCT) uses a rotating fan anode o...

    Yong-Whee Bahk in Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage (2020)

  4. No Access

    Chapter

    Differential Diagnosis of Bone Marrow Edema and Hemorrhage and Callused Trabecular Microfracture with Gamma Correction 99mTc-HDP Pinhole Bone Scan Validation

    Bone marrow edema (BME), bone marrow hemorrhage (BMH), and trabecular microfracture (TMF) comprise a basic triad of bone marrow pathologies ubiquitously incited by trauma, sports, osteoporosis, inflammation, i...

    Yong-Whee Bahk in Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage (2020)

  5. No Access

    Chapter

    99mTc-HDP Pinhole Bone Scanning

    99mTc-HDP (hydroxymethylene diphosphonate) pinhole bone scanning is an ordinary bone imaging technique upgraded by the additional use of a 4-mm aperture pinhole collimator (Bahk et al. 1987; Kim et al. 1999). How...

    Yong-Whee Bahk in Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage (2020)

  6. No Access

    Chapter

    Gamma Correction 99mTc-HDP Pinhole Bone Scan of Trabecular Microfracture and Endosteal Rimming in Rat

    During the recent years, we published some articles on gamma correction medical imaging, gamma correction 99mTc-HDP pinhole bone scan (GCPBS) in particular, for the specific diagnosis of callused trabecular micro...

    Yong-Whee Bahk in Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage (2020)

  7. No Access

    Chapter

    Gamma Correction 99mTc-HDP Pinhole Bone Scan Demonstration of Callused Trabecular Microfracture

    Gamma correction 99mTc-HDP pinhole bone scan can uniquely demonstrate CTMF along with bone metabolic profile. The smallest CTMF imaged on gamma correction pinhole bone scan measures 200 μm in size and this size i...

    Yong-Whee Bahk in Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage (2020)

  8. No Access

    Chapter

    Mathematic and Magnifying Lens Measurements of 99mTc-HDP Uptake in Callused Trabecular Microfracture

    Recently, we developed two kinds of different size-measurement method of the 99mTc-HDP uptake in CTMF. One is the mathematic size quantitation of micro-uptake formed in a gamma correction pinhole scan phantom (Ju...

    Yong-Whee Bahk in Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage (2020)

  9. No Access

    Chapter

    ACDSee-10 Gamma Correction 99mTc-HDP Pinhole Bone Scan of Normal Adult Bone Skeleton Viewed from the Stand Point of Wolff’s Law

    Julius Wolff stated in 1892 that “Every change in the form and function of bone or of their function alone is followed by certain definite changes in their internal architecture, and equally definite alteratio...

    Yong-Whee Bahk in Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage (2020)

  10. No Access

    Chapter

    ACDSee-10 Gamma Correction Conventional Radiography for Demonstration and Size Measurement of Callused Trabecular Microfracture

    Presumably due to rapid, astonishing development of sophisticated modern imaging means such as MRI and MDCT the golden valued conventional radiography seemed to have become unimportantly treated and left behin...

    Yong-Whee Bahk in Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage (2020)

  11. No Access

    Chapter

    Introduction

    As well-known medical imaging science was naturally born in the moment of the discovery of X-ray by W. C. Röntgen in November of 1895 in Würzburg and decades afterward it was followed by the clinical nuclear m...

    Yong-Whee Bahk in Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage (2020)

  12. No Access

    Chapter

    Miscellanea of Gamma Correction Medical Imaging

    Bone marrow edema (BME), bone marrow hemorrhage (BMH) and trabecular microfracture (TMF) are the essential triad of alive marrow bone changes, which homeostatically occur in trauma, sports injuries, osteoporos...

    Yong-Whee Bahk in Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage (2020)

  13. No Access

    Chapter

    Preoperative Radiograph and Gamma Correction 99mTc-HDP Pinhole Scan of Femoral Neck Fracture in Patients

    One day before surgery both conventional radiography and 99mTc-HDP pinhole bone scan were taken in order to anatomically and biochemically confirm the diagnosis of acute femoral neck fracture and thereby resulted...

    Yong-Whee Bahk in Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage (2020)

  14. No Access

    Chapter

    ACDSee-10 Gamma Correction MRI for Neat Imaging and Magnifying Lens Measurement of Callused Trabecular Microfracture

    The excelled usefulness of gamma correction 99mTc-HDP pinhole bone scan for the imaging and diagnosis of callused trabecular microfracture (CTMF) has been well demonstrated and discussed. Now in succession, the s...

    Yong-Whee Bahk in Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage (2020)

  15. No Access

    Chapter

    Morphobiochemical Diagnosis of Callused Trabecular Microfracture Using Gamma Correction 99mTc-HDP Pinhole Bone Scan with Histological Validation

    Callused trabecular microfracture (CTMF) ubiquitously occurs in osteoporosis (Vernon-Roberts and Pirie 1973), bone contusion [Mandalia and Henson], aseptic bone necrosis (McFarland and Frost 1961), inflammator...

    Yong-Whee Bahk in Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage (2020)

  16. No Access

    Chapter

    Gamma Correction

    Gamma correction is a nonlinear image processing algorithm to code and decode the luminance (gray) or tristimulus (color) values in a still image or video system for specific purposes (Holst 1998). The nonline...

    Yong-Whee Bahk in Imaging of Trabecular Microfracture and Bone Marrow Edema and Hemorrhage (2020)

  17. No Access

    Article

    Pixelized Measurement of 99mTc-HDP Micro Particles Formed in Gamma Correction Phantom Pinhole Scan: a Reference Study

    Currently, traumatic bone diseases are diagnosed by assessing the micro 99mTc-hydroxymethylene diphosphonate (HDP) uptake in injured trabeculae with ongoing osteoneogenesis demonstrated by gamma correction pinhol...

    Joo-Young Jung, Gi Jeong Cheon, Yun-Sang Lee in Nuclear Medicine and Molecular Imaging (2016)

  18. No Access

    Book

  19. No Access

    Chapter

    Metabolic Bone Diseases and Drug-Induced Osteoporosis

    Bone scintigraphy has traditionally been considered to be not as useful as radiography in the study of metabolic bone diseases including senile or postmenopausal osteoporosis, osteodystrophy, drug-induced oste...

    Yong-Whee Bahk in Combined Scintigraphic and Radiographic Di… (2013)

  20. No Access

    Chapter

    PET-CT in Bone and Joint Diseases

    Except for acute trauma such as fracture, contusion or sprain, and physical injury such as electric or thermal burn or freezing, the damage to cells in disease starts at the molecular or chemical level followe...

    Yong-Whee Bahk, Sung-Hoon Kim in Combined Scintigraphic and Radiographic Di… (2013)

previous disabled Page of 3