Skip to main content

and
  1. No Access

    Chapter and Conference Paper

    The Effect of the Number of Wire Electrodes on the Performance of Wire Plate Electrostatic Precipitators

    Electrostatic precipitators, which are frequently used in industry, use corona discharge to remove particles from dust air. This article uses COMSOL simulation software to conduct numerical simulation on wire ...

    **nxin Yang, Dongxuan Zhang, Chenlei Han in The Proceedings of 2023 4th International … (2024)

  2. No Access

    Chapter and Conference Paper

    Turn-to-Turn Overvoltage Test Technology for Dry-Type Smoothing Reactor

    The dry-type smoothing reactor is one of the main devices of UHVDC transmission projects. However, the related insulation test is still less than perfect. The turn-to-turn over-voltage test for dry-type reacto...

    Qingsong Liu, Jiajie Huang, Chenlei Liu in The proceedings of the 10th Frontier Acade… (2023)

  3. No Access

    Chapter

    Theoretical Model and Suppressing Method of Interface Charge Accumulation in HVDC Cable Accessory: A Review

    HVDC cable has been widely used with the development of flexible HVDC transmission. Cable accessories are the weakest part of HVDC cables, while the most serious problem of DC cable joint is the uneven distrib...

    ** Li, Chenlei Han, Boxue Du, Tatsuo Takada in Polymer Insulation Applied for HVDC Transm… (2021)

  4. No Access

    Book

  5. No Access

    Chapter

    Magnetic Integration of LCL Filters

    An LCL filter has two individual inductors. In order to reduce the volume of magnetic components, magnetic integration of these two inductors is introduced in this chapter. First, the integration method of the tw...

    **nbo Ruan, Xuehua Wang, Donghua Pan in Control Techniques for LCL-Type Grid-Conne… (2018)

  6. No Access

    Chapter

    Resonance Dam** Methods of LCL Filter

    The control challenges of LCL-type grid-connected inverter arise from the resonance problem. At the resonance frequency, the LCL filter resonance causes a sharp phase step down of −180° with a high resonance peak...

    **nbo Ruan, Xuehua Wang, Donghua Pan in Control Techniques for LCL-Type Grid-Conne… (2018)

  7. No Access

    Chapter

    Design Considerations of Digitally Controlled LCL-Type Grid-Connected Inverter with Capacitor-Current-Feedback Active-Dam**

    The capacitor-current-feedback active-dam** is an effective approach for dam** the resonance peak of the LCL filter. When the LCL-type grid-connected inverter is digitally controlled, the control delay will b...

    **nbo Ruan, Xuehua Wang, Donghua Pan in Control Techniques for LCL-Type Grid-Conne… (2018)

  8. No Access

    Chapter

    Weighted-Feedforward Scheme of Grid Voltages for the Three-Phase LCL-Type Grid-Connected Inverters Under Weak Grid Condition

    The full-feedforward scheme of grid voltages for three-phase LCL-type grid-connected inverter has been introduced in Chap. 7, and the injected grid current harmoni...

    **nbo Ruan, Xuehua Wang, Donghua Pan in Control Techniques for LCL-Type Grid-Conne… (2018)

  9. No Access

    Chapter

    Introduction

    After 200 years of continuous extraction and recent massive consumption, fossil fuels have rapidly become depleted. At the same time, the process of consuming fossil energy has produced a large amount of waste...

    **nbo Ruan, Xuehua Wang, Donghua Pan in Control Techniques for LCL-Type Grid-Conne… (2018)

  10. No Access

    Chapter

    Controller Design for LCL-Type Grid-Connected Inverter with Capacitor-Current-Feedback Active-Dam**

    For the LCL-type grid-connected inverter, the capacitor-current-feedback active-dam** is equivalent to a resistor in parallel with the filter capacitor to damp the LCL filter resonance. This active-dam** meth...

    **nbo Ruan, Xuehua Wang, Donghua Pan in Control Techniques for LCL-Type Grid-Conne… (2018)

  11. No Access

    Chapter

    Full-Feedforward Scheme of Grid Voltages for Three-Phase LCL-Type Grid-Connected Inverters

    In order to alleviate the effect of the grid voltage on the grid current, Chap. 6 presented the full-feedforward scheme of grid voltages for the single-phase LCL-t...

    **nbo Ruan, Xuehua Wang, Donghua Pan in Control Techniques for LCL-Type Grid-Conne… (2018)

  12. No Access

    Chapter

    Reduction of Computation Delay for Improving Stability and Control Performance of LCL-Type Grid-Connected Inverters

    As illustrated in Chap. 8, in the digitally controlled LCL-type grid-connected inverters, proportional feedback of the capacitor current is equivalent to a frequen...

    **nbo Ruan, Xuehua Wang, Donghua Pan in Control Techniques for LCL-Type Grid-Conne… (2018)

  13. No Access

    Chapter

    Impedance Sha** of LCL-Type Grid-Connected Inverter to Improve Its Adaptability to Weak Grid

    As the penetration of distributed power generation systems goes high, the power grid exhibits more like a weak grid which features a large set of grid impedance values and varieties of background voltage harmo...

    **nbo Ruan, Xuehua Wang, Donghua Pan in Control Techniques for LCL-Type Grid-Conne… (2018)

  14. No Access

    Chapter

    Prefilter-Based Synchronous Reference Frame Phase-Locked Loop Techniques

    Due to the significance of extracting the grid voltage information, the grid synchronization system plays an important role in the control of grid-connected power converters, and various grid voltage synchroni...

    **nbo Ruan, Xuehua Wang, Donghua Pan in Control Techniques for LCL-Type Grid-Conne… (2018)

  15. No Access

    Chapter

    Design of LCL Filter

    As the interface between renewable energy power generation system and the power grid, the grid-connected inverter is used to convert the dc power to the high-quality ac power and feed it into the power grid. I...

    **nbo Ruan, Xuehua Wang, Donghua Pan in Control Techniques for LCL-Type Grid-Conne… (2018)

  16. No Access

    Chapter

    Full-Feedforward of Grid Voltage for Single-Phase LCL-Type Grid-Connected Inverter

    The grid-connected inverter plays an important role in injecting high-quality power into the power grid. The injected grid current is affected by the grid voltage at the point of common coupling (PCC). This ch...

    **nbo Ruan, Xuehua Wang, Donghua Pan in Control Techniques for LCL-Type Grid-Conne… (2018)