Weighted-Feedforward Scheme of Grid Voltages for the Three-Phase LCL-Type Grid-Connected Inverters Under Weak Grid Condition

  • Chapter
  • First Online:
Control Techniques for LCL-Type Grid-Connected Inverters

Part of the book series: CPSS Power Electronics Series ((CPSS))

  • 2475 Accesses

Abstract

The full-feedforward scheme of grid voltages for three-phase LCL-type grid-connected inverter has been introduced in Chap. 7, and the injected grid current harmonics and imbalance caused by grid voltages can be effectively suppressed. However, during the derivation of the full-feedforward scheme, the grid impedance is assumed to be zero. For weak grid condition, as the grid impedance becomes large, the full-feedforward scheme might cause the instability of the grid-connected inverter. In this chapter, the stationary α-β frame-controlled three-phase LCL-type grid-connected inverter with the full-feedforward scheme is taken as the example to analyze the system stability under weak grid condition, and the weighted-feedforward scheme is proposed to achieve a trade-off between the stability and the harmonic suppression. With the weighted-feedforward scheme, the extracted and weighted grid voltages are fed forward, and the injected grid current harmonics can be effectively suppressed while the stability of grid-connected inverter under weak grid condition is also guaranteed. Finally, the experimental results verify the analysis in this chapter.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Subscribe and save

Springer+ Basic
EUR 32.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or Ebook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Chapter
USD 29.95
Price excludes VAT (Canada)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 149.00
Price excludes VAT (Canada)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 199.99
Price excludes VAT (Canada)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free ship** worldwide - see info
Hardcover Book
USD 199.99
Price excludes VAT (Canada)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free ship** worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  1. Wang, X., Ruan, X., Liu, S., Tse, C.K.: Full feed-forward of grid voltage for grid-connected inverter with LCL filter to suppress current distortion due to grid voltage harmonics. IEEE Trans. Power Electron. 25(12), 3119–3127 (2010)

    Article  Google Scholar 

  2. Buso, S., Mattavelli, P.: Digital Control in Power Electronics. Morgan and Claypool Publishers, Seattle, WA (2006)

    Google Scholar 

  3. Corradini, L., Stefanutti, W., Mattavelli, P.: Analysis of multi-sampled current control for active filters. IEEE Trans. Ind. Applicat. 44(6), 1785–1794 (2008)

    Article  Google Scholar 

  4. Yang, D., Ruan, X., Wu, H.: Impedance sha** of the grid-connected inverter with LCL filter to improve its adaptability to the weak grid condition. IEEE Trans. Power Electron. 29(11), 5795–5805 (2014)

    Article  Google Scholar 

  5. Sun, J.: Impedance-based stability criterion for grid-connected inverters. IEEE Trans. Power Electron. 26(11), 3075–3078 (2011)

    Article  Google Scholar 

  6. Pan, D., Ruan, X., Bao, C., Li, W., Wang, X.: Capacitor-current-feedback active dam** with reduced computation delay for improving robustness of LCL-type grid-connected inverter. IEEE Trans. Power Electron. 29(7), 3414–3427 (2014)

    Article  Google Scholar 

  7. Liserre, M., Teodorescu, R., Blaabjerg, F.: Stability of photovoltaic and wind turbine grid-connected inverters for a large set of grid impedance values. IEEE Trans. Power Electron. 21(1), 263–272 (2006)

    Article  Google Scholar 

  8. Li, W., Ruan, X., Bao, C., Pan, D., Wang, X.: Grid synchronization systems of three-phase grid-connected power converters: a complex-vector-filter perspective. IEEE Trans. Ind. Electron. 61(4), 1855–1870 (2014)

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to **nbo Ruan .

Rights and permissions

Reprints and permissions

Copyright information

© 2018 Springer Nature Singapore Pte Ltd. and Science Press

About this chapter

Cite this chapter

Ruan, X., Wang, X., Pan, D., Yang, D., Li, W., Bao, C. (2018). Weighted-Feedforward Scheme of Grid Voltages for the Three-Phase LCL-Type Grid-Connected Inverters Under Weak Grid Condition. In: Control Techniques for LCL-Type Grid-Connected Inverters . CPSS Power Electronics Series. Springer, Singapore. https://doi.org/10.1007/978-981-10-4277-5_11

Download citation

  • DOI: https://doi.org/10.1007/978-981-10-4277-5_11

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-10-4276-8

  • Online ISBN: 978-981-10-4277-5

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics

Navigation