Introduction

The treatment of infected bone defects remains a clinical challenge, especially for large and irregular defects. Various methods, such as the vascularized fibula graft [1], and the Masquelet-induced membrane [2,3,4], Ilizarvo bone transport [5,6,7], and structural allograft techniques [8], have been reported for the treatment of large bone defects with good clinical results. However, for defects large in length, the traditional technique requires a longer treatment period and is associated with various complications, such as pin tract infections, docking site nonunion, and joint stiffness. Reducing the treatment cycle and incidence of complications, obtaining good mechanical stability, and improving the fusion rate have become key to successful treatment [9].

With the development of three-dimensional (3D) printing technology, 3D-printed implants have been used for defect reconstruction. They have several advantages, such as their lack of need for additional bone grafting, immediate stability, customized matched shape to fill the defect, and ability to accurately correct length discrepancies, which make them widely used in the treatment of bone defects caused by tumor resection [10,11,12,13,14,15], trauma [16] and infection [17, 18], especially for large extremity defects. However, some researchers have reported a high incidence of complications during long-term follow-up, which significantly affect the reconstruction survival rate. In a recent study [16,17,18,19], the porous scaffold structure enable not only short-term effect but also long-term stability. By adjusting the porosity and pore size to fit the elastic modulus of the bone, stress shielding effects and mechanical failure can be effectively prevented [20,21,22], offering the possibility of long-term stability and good conditions for osseointegration. In clinical practice, this porous prosthesis has been used for the reconstruction of bone defects after tumor resection of the extremity diaphysis, and the pelvis has demonstrated good short-term bone ingrowth effects [23,24,25,26]. Thus, to shorten the treatment cycle of the infected bone defect and compensate for the insufficiency of conventional techniques, we used a 3D-printed porous prosthesis in the treatment of femoral defects caused by osteomyelitis. We have used an intramedullary nail to realize micromotion with certain parameters, while maintaining prosthesis stability. In our previous research, short-term effectiveness was demonstrated both in animals and clinics [22, 27, 28]. In the present study, we prospectively evaluated a group of 11 patients with femoral bone defects who underwent reconstruction with a 3D-printed porous prosthesis, with a mean follow-up period of 43 months. The aim was to investigate the long-term stability of this novel fixation system, its complication rate, and the effects of osseointegration.

Materials and methods

Patients

We have prospectively studied 11 consecutive patients (7 male and 4 female) with femoral bone defects caused by osteomyelitis or infected nonunion after fracture who were treated at our institution between May 2017 and July 2021. Patients with defects due to tumor resection or Charcot arthropathy and those with less than 1 year of follow-up were excluded. The mean patient age was 52.4 years (range: 24–79 years). The patients underwent a mean of 4.4 debridements before prosthetic implantation. The mean length of the bone defect was 14.0 cm, and the largest defect was 26.1 cm. The mean follow-up was 43.0 months (range: 24–68 months). All patients provided informed consent for their participation.

Surgical technique

Similar to the Masquelet technique [3], we used a two-stage treatment approach. In the first stage, the patients were placed on an orthopedic operating table. A lateral incision was made to clean up the infected soft tissue and necrotic bone until bleeding was observed at the bone margin. The proximal and distal interfaces were trimmed to a plane perpendicular to the long axis of the femoral diaphysis. After reaming the femoral canal, the entire surgical area was repeatedly flushed with hydrogen peroxide and iodophor solution to ensure that the local infection was under control. The bone tissue, surrounding soft tissue, and irrigation fluid were retained for bacterial culture during surgery. A vancomycin-loaded polymethylmethacrylate (PMMA) spacer which consisted of 40 g PMMA bone cement and 2 g vancomycin was used to fill the spaces and canals. According to the length and diameter of the defects, the PMMA should be slightly larger to ensure sufficient space for the prosthesis and maintain the length of the lower limbs. Vacuum sealing drainage (VSD) was used for continuous wound irrigation, and the drainage fluid was retained for 3 days postoperatively for bacterial culture. Debridement was performed weekly until all antibiograms and cultures were negative. PMMA spacing should be performed for 6–8 weeks to generate a high-quality induction membrane and confirm that no infection remains. External fixation was used to maintain stability of the extremity in nine patients with critical-size defects. After the first stage of treatment, patients were asked to undergo computed tomography (CT) of both lower extremities, which was used to design and fabricate the 3D-printed prosthesis during the waiting period. Based on CT, patients with radiographically apparent bone gaps were defined as having critical defects. Patients with continuous bone cortex were defined as having shape-structural defects.

Before the second stage of treatment, the soft tissue and wound conditions, white blood cell count levels (WBC), leukocyte counts, C-reactive protein levels (C-rp), and erythrocyte sedimentation rates (ESR) were evaluated to ensure local infection control. The PMMA spacer was removed by carefully incising the membrane. The 3D-printed prostheses of all patients were inserted with 2 g vancomycin into the drug-loaded hollows. For patients with critical defects, the intramedullary nails (Smith & Nephew Medical Ltd.) were used to keep the prosthesis stable while distributing stress on the prosthesis. The wound was closed in layers, as usual. Postoperatively, according to pathogen susceptibility tests, intravenous and oral empiric antibiotics were administered for 1 month. During the waiting period of the first and second stages, all patients were required to take oral second-generation cephalosporins.

Prosthesis design

The prosthesis design process was conducted between the first and second stages with the participation of AK Medical Holding Ltd. According to the workflow [29], the 3D structure was first projected using the Mimics software (Mimics 21.0; Materialise, Leuven, Belgium) based on the length of the healthy femur and anatomical shape of the defect area. The size of the prosthesis interface should be smaller in diameter than that of the host bone to help new bone tissue to crawl and grow towards the prosthesis. The material of the prosthesis was titanium alloy (Ti6Al4V), according to previous literature and our animal experiments [20,21,22]. The prosthesis was constitutive of regular icosahedron units with a porosity of approximately 60–70% and a pore size of 625 ± 70 μm. All prostheses used in critical-size defects had a hollow design to mimic the structure of the medullary cavity (Fig. 1). To facilitate the application of intramedullary nails, the diameter of the hollow portion was designed 1–1.5 mm larger than the diameter of the intramedullary nail. According to our previous finite element analysis based on ABAQUS 6.13, the stress was mostly concentrated at the prosthesis interface [30]; therefore, the intramedullary nail could effectively disperse the lateral stress on the prosthesis while limiting the lateral dislocation of the prosthesis. By this means, the risk of aseptic loosening and prosthetic fracture was reduced, which aids the immediate stabilization of the prosthesis. In addition, the presence of an intramedullary nail allowed for micromotion between the prosthesis and bone interface to facilitate osseointegration. Three locking nails were used for distal femur to prevent prosthesis subsidence.

Fig. 1
figure 1

A and B the design drawings of the 3D printed prosthesis. C the finished photo of 3D printed prosthesis, a lateral plate was added to ensure strength

When the defect involved the metaphysis, proper and rigid fixation was difficult to achieve because of its special anatomical structure and insufficient anchorage length [25, 31]. Hence, the prosthesis was designed with a lateral wing plate that was 3–4 cm long and fixed with three to four screws to enhance its stability. Although bone growth is affected to some extent by the stress shielding effect [22, 30], it effectively prevents prosthesis failure due to excessive micromotion.

If the distal bone of the metaphysis was considered insufficient to lock the intramedullary nail, an integrated intramedullary nail prosthesis was applied. The distal portion of the prosthesis was stabilized using four screws that penetrated the prosthesis to fix the distal bone.

For shape-structural bone defects, because of the presence of a continuous bone cortex for lower extremity stabilization, the design of the prosthesis was fully compatible with the anatomical morphology of the defect area to ensure a complete fit to the host bone after implantation. Proximal and distal lateral plates were designed for fixation to ensure stable transmission of cortical stress from the defect site to the distal part, which provided a basis for early weight-bearing of the limb (Fig. 2). All patients did not require bone grafting.

Fig. 2
figure 2

A A 51-year-old patient suffered osteomyelitis after a femur injury. B After debridement three times, an external fixator was applied, and PMMA was used to fill the spacer. The length of defect was 26.1 cm. C and D Anteroposterior (C) and lateral radiographs (D) showing the stability of the reconstruction system after 2 years. The bone growth could be observed proximally. E and F There was no limb-length discrepancy. The patient achieved full weight-bearing and was able to resume his original work. PMMA = polymethylmethacrylate

Postoperative management

The patients without osteoporosis or evidence of skin or soft tissue infection, were permitted to perform partial weight-bearing or knee flexion and extension training after removal of the drainage tube 1 week post-operatively. Patients with osteoporosis, skin flaps, or poor skin conditions were allowed to perform toe-touch weight-bearing with crutches 1 week post-operatively. Rehabilitation of full-range joint mobility training in bed was also encouraged, and full weight-bearing was gradually resumed within 2 months.

Clinical and radiographic evaluation

Clinical and radiographic evaluations were conducted at 1, 3, and 6 months for the first year after surgery and every year thereafter. At each follow-up, a senior surgeon assessed the patients for infection relapse by probing the wound. The absence of sinus tract, material exposure, or pus within the wound was ensured. Infection eradication was characterized by a healed wound after one year of follow-up. Patients were asked to undergo full-length, frontal, and lateral radiographs of both lower extremities at each follow-up visit to observe prosthesis stability, proximal and distal bone cortical thickness, and bone growth. Union was considered to occur when the new bone grew into or climb over a porous structure. However, osseointegration was not observed upon radiographic examination; thus, we chose to observe trabecular bridging across the prosthesis-host junction on radiography and recorded the time of formation to indirectly evaluate the effect of osseointegration [32]. Based on evaluation of postoperative X-rays, union was defined if the following criteria were met: (1) prosthetic dislocation < 2 mm; (2) continuous bone formation across the bone interface and extent of prosthesis (proximal or distal); (3) no remaining infection; and (4) no periprosthetic translucent band on radiography. A dislocation of > 2 mm was defined as prosthetic loosening. Functional recovery was assessed using the lower extremity functional scale (LEFS). Neurovascular status, range of motion (ROM) of the knee joints, and any signs of infection were examined.

Results

Demographic and follow-up data are detailed in Table 1 and laboratory data in Table 2. Among the eight patients with critical-size bone defects, five had metaphysis defects, one of whom used an integrated intramedullary nail prosthesis due to insufficient distal bone, and the others used a lateral plate-type prosthesis combined with an intramedullary nail. Three patients in whom the defect only involved the diaphysis were treated with a plain prosthesis and intramedullary nail. Among the three patients with shape-structural defects, two had involvement of the metaphysis, and one only had involvement of the diaphysis. Union was achieved in 10 (91%) patients according to our criteria. One patient who used an integrated intramedullary nail prosthesis was defined as having nonunion due to the presence of a translucent band on the distal bone after 36 months of follow-up, considering periprosthetic bone resorption (Fig. 3). The patient showed good functional performance at the latest follow-up visit. Among patients with shape-structural defects, one patient obtained fair results because of continuous postoperative pain with a visual analog scale (VAS) score of 4–5 and requirement for pain medication.

Table 1 Demographic data, infected data, details bone loss and treatment, and results of patients
Table 2 Infected data and laboratory examination results of patients
Fig. 3
figure 3

Anteroposterior and lateral radiographs at 36 months follow-up. A The wound healed well with no evidence of infection. B The metaphysis was considered insufficient to lock the intramedullary nail, an integrated intramedullary nail prosthesis was applied. C Prosthesis was stabilized using screws that penetrated the prosthesis. D Translucent zone surrounding the prothesis could be observed both on proximal and distal bone with no new bone growth. E Sclerosis of the distal interface

Radiological outcomes

In the critical-size defect group, two patients showed a prosthesis dislocation of < 2 mm compared with the immediate preoperative radiograph. However, no patient showed significant angulation or subsidence, and functional recovery was satisfactory. Proximal bone growth was observed in 6 patients at 6 months follow-up and in 1 patient at 12 months follow-up. Distal bone growth was observed in only two patients, and both bone defects only involved the diaphysis. One patient had an integral intramedullary nail, sclerosis of the distal interface, and a translucent zone surrounding the prosthesis, and no significant bone growth was observed until the last follow-up.

In patients with shape-structural defects, no dislocation was identified. Bone growth was observed at both the proximal and distal interfaces in 1 patient with diaphyseal defects at 12 months. In 2 patients with metaphysis, bone growth was observed unilaterally at 6 and 12 months, with significant osteosclerosis on the other side. Periprosthetic cortical thickening was observed in all patients, with no translucent bands Table 3.

Table 3 Radiological result

Discussion

3D-printed protheses are most commonly used in the treatment of large bone defects after tumor resection to achieve rapid weight-bearing. However, in previous reports, the prosthesis design focused only on anatomical reconstruction with a solid stem. Aseptic loosening and periprosthetic fractures were the most common complication, with rates ranging 33–53.8% [10,11,12,13,14, 33], which limits the prothesis application. With technological developments, the novel porous structure design showed satisfactory osseointegration, providing long-term effectiveness of prostheses. Hence, we applied 3D-printed technology to treat infected bone defects to shorten the treatment cycle and compensate for graft bone insufficiencies. In our study, we reported a union rate of 91%, which was comparable to that of conventional treatment methods [1,2,3,4,5,6,7,8].

3D-printed porous prosthesis combined with an intramedullary nail fixation system improved performance and achieved reconstruction

To guarantee prosthesis stability and a controllable micromotion environment, we chose an intramedullary nail to disperse the stress. This effectively avoided peak stress being concentrated on the prosthesis, thereby reducing the risk of prosthetic or periprosthetic fracture. In diaphyseal defects, the load is transmitted from the proximal to the distal host bone to prevent stress-shielding effects and promote osteogenesis. In metaphyseal cases, because the plate was fixed with screws on the distal side, less stress was transmitted to the distal bone. The stress was concentrated on the lateral plate of the prosthesis, improving prosthesis stability and preventing the impact of rotation stress in the metaphysis.

Traditional customized prostheses are manufactured using one-piece structures. The stem was made into one piece with a prosthetic body and connected to a special piece. When used for femur reconstruction, the most frequent problems were aseptic stem loosening and structural failure, with rates ranging 16.7–57.0% [10, 12,13,14]. Benevenia [10] reported that 12 patients who underwent femur reconstruction with a prosthesis suffered implant-related complications, and a clamp-rod interface fracture was associated with cemented fixation of the stem. However, aseptic stem loosening was more likely to be caused by non-cemented fixation. Mahdal [13] also reported clamp-rod interface fractures after cement fixation, and the risk was higher when the defect length was > 10 cm [15] or involved meta-diaphyseal regions [14], indicating that stress was concentrated on the relatively unstable part of the prosthesis and not homogeneously distributed.

Porous prostheses seemingly have a lower implant-related complication rate than solid prostheses. Among 39 patients who received a custom 3D-printed implant, Abar [16] reported that 25.6% suffered implant loosening within 10 months. Zhao [11] used a porous prosthesis combined with a locking plate in 14 patients; none of whom developed implant-related complications at the final follow-up. Hammaa [34] used custom 3D-printed titanium truss cages combine with intramedullary nails also achieved favorable clinical outcomes with no occurrences of implant loosening. The formation of the bone bridge and the distance of infiltration into the implant may contribute to prosthesis stability.

According to our results, osseointegration mostly occurred at 6–12 months with no implant loosening or structural failure. In critical-sized defects, proximal osteogenesis started earlier than distal osteogenesis, and medial osteogenesis started earlier than lateral osteogenesis. However, owing to the stress-shielding effect, osteogenesis occurred later in distal metaphysis cases. Moreover, the prosthesis was fixed to the bone using intramedullary nailing, which limits the horizontal micromotion between the bone and prosthesis, enabling micromotion along the axis of the femoral stem, which differs from the traditional fixed system. As stability increased, micromotion disappeared, and bone growth halted [22]. Most patients in our study were allowed partial weight-bearing after drainage removal 1-week post-operatively, which may contribute to satisfactory functional outcomes and a shorter treatment period. However, dynamic stability and stress stimulation may enhance osseointegrative potential.

Potential factors affecting osseointegration

Good osseointegration may improve prosthesis longevity, making it applicable for the treatment of non-tumor bone defects. In previous research [21, 22, 35], scaffolds with a porosity of 60–80% and pore sizes of 500-700um have been demonstrated to effectively promote bone ingrowth. The research [36] indicated that the scaffolds with a small pore size that smaller than 188um, the exchange of oxygen and nutrients would be affected, and failed to provide adequate surface area for cell adsorption and proliferation. Furthermore, by adjusting the porosity to match the elastic modulus of cortical bone (4 – 30 GPa) [37, 38], stress shielding could be prevented. Additionally, to avoid excessive weight of the implant, the entire implant also utilized a porous structure.

Bone formation within porous networks has previously been observed in bone tissue sections [22, 27, 28]; however, it cannot be directly observed in vivo. Therefore, in our study, we determined the bone ingrowth effect by observing periprosthetic bone formation and cortical thickness on radiography, which was reported previously [11, 16, 31]. We herein summarize several reasons to explain the different osteogenesis effects between proximal and distal bone: (1) enlarged sectional diameter of the distal femur dispersed stress; (2) the lower third of the femur has a poor degree of vascularization [39], which affects osteogenesis; and (3) the stress-shielding effect of the lateral plate of the metaphyseal prosthesis [22, 30], and the lack of micromotion due to rigid fixation. Therefore, we propose the necessity to conduct weight-bearing training within two weeks if feasible. In the shape-structural defect group, callus growth was found on the non-plate side and occurred slower than that in the critical defect group, which may be related to the locking screw fixation of the prosthesis.

At study onset, we hoped to retain more host bone to reduce surgical trauma and improve osseointegration; therefore, the bone interface did not flatten during the first stage. However, during long-term follow-up, in one patient with an integrated intramedullary nail prosthesis, the bone did not grow at the interface parallel to the lower limb force line. Bony sclerosis and transparent periprosthetic bands are observed at the bone interface, and resorption occurs at the contact interface because of the lack of stress stimulation. Therefore, we suggest the host bone interface be as flat as possible to ensure a uniform stress distribution and be perpendicular to the direction of the force line to ensure sufficient stress to stimulate new bone growth. Until the last follow-up, the patient had no significant decline in lower limb function, and we were not hurried to intervene.

The present study has several limitations. First, the sample size was small, and a larger sample size is needed to confirm the results. Second, the 3D-printed prosthesis was made of titanium alloy, which is not absorbable. Although the longest case achieved good treatment results more than 5 years after surgery, longer follow-up is needed to corroborate the effectiveness and safety of this treatment method. Third, there are no quantitative indicators to describe the osseointegration effect, and more cases are required to summarize the pattern of osteogenesis.

Conclusion

Based on the current outcomes, the application of 3D-printed porous prosthesis could help to reconstruct local anatomy rapid and provided stable mechanical transmission. The application of the intramedullary nail provides mechanical dispersion and ensures the presence of micromotion, which can effectively shorten the treatment time, provide a relatively stable bone defect repair mode, avoid additional bone grafting, and achieve satisfactory clinical results in the medium-term; therefore, it is a potentially effective choice for the treatment of infected bone defects.