We are improving our search experience. To check which content you have full access to, or for advanced search, go back to the old search.

Search

Please fill in this field.

Search Results

Showing 1-20 of 1,992 results
  1. Coronary calcium scoring on virtual non-contrast and virtual non-iodine reconstructions compared to true non-contrast images using photon-counting computed tomography

    Objectives

    To compare coronary artery calcification (CAC) scores measured on virtual non-contrast (VNC) and virtual non-iodine (VNI) reconstructions...

    Simran P. Sharma, Judith van der Bie, ... Ricardo P. J. Budde in European Radiology
    Article Open access 09 November 2023
  2. Electron density dual-energy CT can improve the detection of lumbar disc herniation with higher image quality than standard and virtual non-calcium images

    Objectives

    To compare the diagnostic performance and image quality of dual-energy computed tomography (DECT) with electron density (ED) image...

    Juhyun Jeong, Sungwon Ham, ... Hangseok Choi in European Radiology
    Article 16 May 2024
  3. Virtual non-contrast series of photon-counting detector computed tomography angiography for aortic valve calcium scoring

    The aim of our study was to evaluate two different virtual non-contrast (VNC) algorithms applied to photon counting detector (PCD)-CT data in terms...

    Franka Risch, Eva Harmel, ... Josua A. Decker in The International Journal of Cardiovascular Imaging
    Article Open access 04 January 2024
  4. Heart rate sensitivity of virtual non-contrast calcium scores derived from photon counting detector CT data: a phantom study

    Purpose

    To assess the reliability of virtual non-contrast (VNC) derived coronary artery calcium quantities in relation to heart rate and the VNC...

    Franka Risch, Florian Schwarz, ... Josua A. Decker in La radiologia medica
    Article Open access 06 February 2024
  5. Feasibility of virtual non-iodine coronary calcium scoring on dual source photon-counting coronary CT angiography: a dynamic phantom study

    Background

    The aim of our current systematic dynamic phantom study was first, to optimize reconstruction parameters of coronary CTA (CCTA) acquired on...

    Magdalena M. Dobrolinska, Lennart R. Koetzier, ... Niels R. van der Werf in European Radiology
    Article Open access 24 May 2024
  6. Impact of Cardiac Motion on coronary artery calcium scoring using a virtual non-iodine algorithm on photon-counting detector CT: a dynamic phantom study

    This study assessed the impact of cardiac motion and in-vessel attenuation on coronary artery calcium (CAC) scoring using virtual non-iodine (VNI)...

    Nicola Fink, Emese Zsarnoczay, ... Tilman Emrich in The International Journal of Cardiovascular Imaging
    Article 15 July 2023
  7. Diagnostic performance of electron-density dual-energy CT in detection of cervical disc herniation in comparison with standard gray-scale CT and virtual non-calcium images

    Objectives

    To assess the diagnostic performance of dual-energy CT (DECT) with electron-density (ED) image reconstruction compared with standard CT...

    Euddeum Shim, Baek Hyun Kim, ... Thomas J. Kwack in European Radiology
    Article 22 January 2022
  8. Synthetic hematocrit from virtual non-contrast images for myocardial extracellular volume evaluation with photon-counting detector CT

    Objectives

    To assess the accuracy of a synthetic hematocrit derived from virtual non-contrast (VNC) and virtual non-iodine images (VNI) for myocardial...

    Victor Mergen, Nicolas Ehrbar, ... Matthias Eberhard in European Radiology
    Article Open access 27 June 2024
  9. Dual-energy CT virtual non-calcium: an accurate method for detection of knee osteoarthritis-related edema-like marrow signal intensity

    Objectives

    To evaluate the performance of a dual-energy computed tomography (DECT) virtual non-calcium (VNCa) technique in the detection of edema-like...

    Heng Zhao, Hui Li, ... Shi-nong Pan in Insights into Imaging
    Article Open access 30 April 2023
  10. Virtual noncontrast images reveal gouty tophi in contrast-enhanced dual-energy CT: a phantom study

    Background

    Dual-energy computed tomography (DECT) is useful for detecting gouty tophi. While iodinated contrast media (ICM) might enhance the...

    Karim Khayata, Torsten Diekhoff, ... Maximilian Kotlyarov in European Radiology Experimental
    Article Open access 12 June 2024
  11. Dual-energy CT of the pancreas: comparison between virtual non-contrast images and true non-contrast images in the detection of pancreatic lesion

    Purpose

    To evaluate the image quality and diagnostic performance for pancreatic lesion between true non-contrast (TNC) and virtual non-contrast (VNC)...

    Hongwei Liang, Silin Du, ... Yongmei Li in Abdominal Radiology
    Article 20 May 2023
  12. Virtual non-calcium dual-energy CT: clinical applications

    Dual-energy CT (DECT) has emerged into clinical routine as an imaging technique with unique postprocessing utilities that improve the evaluation of...

    Tommaso D’Angelo, Moritz H. Albrecht, ... Christian Booz in European Radiology Experimental
    Article Open access 03 September 2021
  13. CT radiomic features reproducibility of virtual non-contrast series derived from photon-counting CCTA datasets using a novel calcium-preserving reconstruction algorithm compared with standard non-contrast series: focusing on epicardial adipose tissue

    Purpose

    We aimed to evaluate the reproducibility of computed tomography (CT) radiomic features (RFs) about Epicardial Adipose Tissue (EAT). The...

    MengXu Cui, ShouYu Bao, ... Wenjie Yang in The International Journal of Cardiovascular Imaging
    Article 08 April 2024
  14. Calcium scoring using virtual non-contrast images from a dual-layer spectral detector CT: comparison to true non-contrast data and evaluation of proportionality factor in a large patient collective

    Objective

    Determination of coronary artery calcium scoring (CACS) in non-contrast computed tomography (CT) images has been shown to be an important...

    Felix G. Gassert, Claudio E. Schacky, ... Jonathan Nadjiri in European Radiology
    Article Open access 20 January 2021
  15. Assessment of epicardial adipose tissue on virtual non-contrast images derived from photon-counting detector coronary CTA datasets

    Objectives

    To assess epicardial adipose tissue (EAT) volume and attenuation of different virtual non-contrast (VNC) reconstructions derived from...

    Franka Risch, Florian Schwarz, ... Josua A. Decker in European Radiology
    Article Open access 03 December 2022
  16. Influence of BMI on virtual coronary artery calcium scoring

    Purpose

    Virtual non-contrast (VNC) coronary artery calcium scoring (CAC) may obviate the need for traditional non-contrast (TNC) CAC. There is no data...

    Javier Perez-Cervera, Javier Arce, ... Leandro Slipczuk in The International Journal of Cardiovascular Imaging
    Article 30 December 2022
  17. Incremental diagnostic value of color-coded virtual non-calcium dual-energy CT for the assessment of traumatic bone marrow edema of the scaphoid

    Objectives

    To investigate the diagnostic accuracy of color-coded dual-energy CT virtual non-calcium (VNCa) reconstructions for the assessment of bone...

    Vitali Koch, Felix Christoph Müller, ... Christian Booz in European Radiology
    Article 06 January 2021
  18. Optimized signal of calcifications in wide-angle digital breast tomosynthesis: a virtual imaging trial

    Objectives

    Evaluate microcalcification detectability in digital breast tomosynthesis (DBT) and synthetic 2D mammography (SM) for different acquisition...

    Liesbeth Vancoillie, Lesley Cockmartin, ... Hilde Bosmans in European Radiology
    Article 28 March 2024
  19. Optimization of window settings for coronary arteries assessment using spectral CT-derived virtual monoenergetic imaging

    Purpose

    To determine the optimal window setting for virtual monoenergetic images (VMI) reconstructed from dual-layer spectral coronary computed...

    Tommaso D’Angelo, Domenico Mastrodicasa, ... Christian Booz in La radiologia medica
    Article Open access 27 June 2024
  20. Quality of virtual-non-contrast phases derived from arterial and delayed phases of fast-kVp switching dual-energy CT in patients after endovascular aortic repair

    Objective of this study is: to analyze CT numbers in arteries and endoleaks in true non-contrast (TNC) and virtual non-contrast phases derived from...

    Wojciech Kazimierczak, Natalia Kazimierczak, Zbigniew Serafin in The International Journal of Cardiovascular Imaging
    Article Open access 14 June 2023
Did you find what you were looking for? Share feedback.