Search
Search Results
-
The pelvic vascular injury score (P-VIS): a prehospital instrument to detect significant vascular injury in pelvic fractures
PurposeThe purpose of this study was to identify predictive factors for peri-pelvic vascular injury in patients with pelvic fractures and to...
-
Current Management of Hemodynamically Unstable Patients with Pelvic Fracture
Purpose of ReviewTrauma patients with a high-energy mechanism may sustain severe pelvic injury, leading to increased mortality from hemorrhage....
-
Arterial angioembolisation versus pre-peritoneal pelvic packing in haemodynamically unstable patients with complex pelvic fractures: a meta-analysis
IntroductionAngioembolisation (AE) and/or pre-peritoneal pelvic packing (PPP) may be necessary for patients with complex pelvic fractures who are...
-
Standard practice in the treatment of unstable pelvic ring injuries: an international survey
PurposeUnstable pelvic ring injury can result in a life-threatening situation and lead to long-term disability. Established classification systems,...
-
Intelligent robot-assisted fracture reduction system for the treatment of unstable pelvic fractures
BackgroundPrecise and minimally invasive closed reduction is the premise of minimally invasive internal fixation. This paper aims to explore the...
-
Management of Pelvic Trauma-Associated Urethral Injury in Men
Purpose of the ReviewTrauma is a prevalent cause of morbidity and mortality for the US and the world population. Pelvic fractures are often...
-
Unstable pelvic fractures in women: implications on obstetric outcome
PurposeObstetric outcomes in women following pelvic injuries requiring surgical fixation is not thoroughly known. We aimed to evaluate if...
-
Modified percutaneous iliosacral screw and anterior internal fixator technique for treating unstable pelvic fractures: a retrospective study
BackgroundThe commonly used technique for treating unstable pelvic fractures with sacroiliac screws and anterior internal fixator (INFIX) is prone to...
-
Comparison of T-POD and SAM Pelvic Sling II and the influence of attachment level in the initial management of unstable pelvic type C injuries – a cadaveric study
BackgroundType C pelvic fractures (AO/OTA) are severe injuries that frequently lead to bleeding and hemodynamic instability. Pelvic binders play a...
-
Combined pelvic and acetabular injuries: clinical features and treatment strategies of a unique injury pattern
BackgroundTo explore the clinical characteristics of patients with unstable pelvic fractures combined with acetabular fractures and to discuss the...
-
Does sequential examination under anaesthesia provide a reliable method to determine a management plan for unstable lateral compression pelvic ring injuries? a prospective study
PurposeTo assess the reliability of sequential examination under anaesthesia (EUA) to determine pelvic instability and to evaluate radiological and...
-
Preoperative CT simulation of iliosacral screws for treating unstable posterior pelvic ring injury
BackgroundThe percutaneous iliosacral screw is a common procedure for treating pelvic posterior ring instability. Traditional X-ray fluoroscopy screw...
-
A clinical and biomechanical comparison of INFIX plus single versus double sacroiliac screw fixation for unstable pelvic ring injury
BackgroundThe aim of this study is to compare the clinical and biomechanical outcome of INFIX plus single with two sacroiliac screw fixation for...
-
Is unrestricted weight bearing immediately after fixation of rotationally unstable pelvic fractures safe?
IntroductionRotationally unstable pelvic fractures treated with surgical fixation have traditionally been treated with restricted weight bearing on...
-
Oblique anterior pelvic external fixator for intraoperative reduction of rotationally unstable pelvic ring injuries
Incomplete sacroiliac joint injuries are often associated with external rotation and extension deformities on the injured hemipelvis. To...
-
Hidden blood loss and the influential factors after minimally invasive treatment of posterior pelvic ring injury with sacroiliac screw
BackgroundTo analyze the perioperative bleeding and hidden blood loss (HBL) of sacroiliac screw minimally invasive treatment of pelvic posterior ring...
-
Fluoroscopy guided teardrop technique for open trans-muscular iliac screw placement and open reduction maneuvers during modified triangular spinopelvic fixation for unstable U-shaped sacral and tile C pelvic traumas: technical note
Unstable traumas of the spinopelvic junction, which include displaced U-shaped sacral fractures (Roy-Camille type 2 and type 3) and Tile C vertical...
-
Emergency treatment of pelvic ring injuries: state of the art
High energy pelvic injuries sustain significant mortality rates, due to acute exsanguination and severe associated injuries. Managing the...
-
Role of pelvic packing in the first attention given to hemodynamically unstable pelvic fracture patients: a meta-analysis
PurposeTo evaluate the effectiveness of pelvic packing (PP) in pelvic fracture patients with hemodynamic instability.
Materials and methods ... -
The EMS stress view: occult pelvic instability revealed by pre-hospital pelvic binder placement
PurposeTo describe and evaluate the serendipitous pelvic binder stress radiographs of lateral compression type (LC) pelvic ring injuries.
...