Search
Search Results
-
The effect of ding’s screw and tension band wiring for treatment of olecranon fractures: a finite element study
BackgroundTension band wiring (TBW) is a common surgical intervention for olecranon fractures. However, high rate of complications such as loss of...
-
Comparative study of locking neutralization plate construct versus tension band wiring with a cannulated screw for patella fractures: experimental and finite element analysis
Transverse patella fractures, accounting for approximately 1% of Orthopedic injuries, pose intricate challenges due to their vital role in knee...
-
Natural behaviours after guided growth for idiopathic genu valgum correction: comparison between percutaneous transphyseal screw and tension-band plate
BackgroundPercutaneous epiphysiodesis using a transphyseal screw (PETS) or tension-band plating (TBP) has shown favourable correction results;...
-
The infraacetabular screw versus the antegrade posterior column screw in acetabulum fractures with posterior column involvement: a biomechanical comparison
IntroductionTraditionally, plate osteosynthesis of the anterior column combined with an antegrade posterior column screw is used for fixation of...
-
A novel technique of a new cannulated screw for treatment of inferior pole patellar fractures: a finite element study
ObjectiveWe invented a new cannulated screw with holes on the tail, which called Ding’s screw. The goal of this study was to evaluate the...
-
Predictors of accurate intrapedicular screw placement in single-level lumbar (L4-5) fusion: robot-assisted pedicle screw, traditional pedicle screw, and cortical bone trajectory screw insertion
BackgroundThe superiorities in proximal facet joint protection of robot-assisted (RA) pedicle screw placement and screw implantation via the cortical...
-
Novel screw-cable integrated system(SCIS) for minimally invasive treatment of patella transverse fractures: a finite element analysis
BackgroundThe most recommended method for treating transverse patella fractures is modified tension band wiring (MTBW). However, the optimal...
-
Biomechanical comparison of different screw-included angles in crossing screw fixation for transverse patellar fracture in level walking: a quasi-dynamic finite element study
BackgroundA minimally invasive technique with various screw configurations without open surgery is currently used for the fixation of transverse...
-
Bionic reconstruction of tension trabeculae in short-stem hip arthroplasty: a finite element analysis
BackgroundShort-stem hip arthroplasty (SHA) is characterized by metaphyseal load transfer that effectively preserves the bone stock, but still...
-
Biomechanical comparison of screw vs. cerclage refixation in orthogeriatric lesser trochanteric fractures: a cadaveric study
PurposeOsteoporosis-related proximal femur fractures continue to increase significantly due to demographic change. This study was designed to...
-
Inter-screw index as a novel diagnostic indicator of tether breakage
PurposeTether breakage is the most common complication of Vertebral Body Tethering (VBT) occurring in up to 52% of Adolescent Idiopathic Scoliosis...
-
Gait Analysis in Patients with Symptomatic Pes Planovalgus Following Subtalar Arthroereisis with the Talus Screw
BackgroundPes planovalgus is one of the most common pediatric skeletal deformities. There have been no studies to analyze in detail the...
-
Impact of osteosclerosis on cervical pedicle screw insertion using preoperative CT-based navigation
PurposePreoperative computed tomography (CT)-based navigation is used for cervical pedicle screw (CPS) insertion to mitigate the risk of spinal cord...
-
Is lower screw density associated with mechanical complications in adult spinal deformity surgery?
PurposeTo assess the impact of screw density on: (1) rod fracture/pseudarthrosis, (2) proximal/distal junctional kyphosis/failure (PJK/DJK/PJF), and...
-
Use of the iliac-outlet and iliac-inlet combined views in percutaneous posterior column retrograde screw fixation
Posterior column fractures are common acetabular injuries. Although displaced fractures require open reduction and fixation, undisplaced patterns may...
-
Superior short-term outcomes of FNS in combination with a cannulated screw in treating femoral neck fractures
BackgroundThis study aimed to evaluate the clinical efficacy of the femoral neck system alone or in combination with a cannulated screw compared with...
-
Comparative fixation devices for preventing migration of the proximal tibiofibular joint during tibial lengthening: a tether versus screw fixation
BackgroundWhen lengthening the tibia segment using motorized internal lengthening nails (MILN), undesired distal migration of the proximal fibula...
-
Femoral interference screw insertion significantly increases graft tension in medial patellofemoral ligament reconstruction
PurposeThis study aimed to quantify the effect of interference screw insertion on MPFL graft tension when securing the femoral attachment after...
-
Arthroscopy-assisted reduction and simultaneous robotic-assisted screw placement in the treatment of fractures of the posterior talar process
PurposeA fracture of the posterior talar process is easily missed because of its hidden position. Inappropriate treatment is likely to result in...