Search
Search Results
-
The application of magnetic anchoring traction device in assisting donor liver bench surgery in classic orthotopic liver transplantation
ObjectiveTo explore the clinical application of a newly developed magnetic anchoring traction (MAT) system in the liver bench trimming and...
-
A novel anchoring system for pelvic organ prolapse repair: an observational study
Introduction and hypothesisSacrospinous ligament (SSL) fixation is an effective and widely used vaginal procedure for correcting apical prolapse. The...
-
Combining anchoring with financial incentives to increase physical activity: a randomized controlled trial among college students
The purpose of this study was to: (1) compare the relative efficacy of different combinations of three behavioral intervention strategies (i.e.,...
-
Evaluation of the safety and efficacy of a novel Anatomical classification and dUal anchoRing theory to Optimize the tavR strategy for pure severe Aortic regurgitation (AURORA): a prospective cohort study
BackgroundSuccess rate of transcatheter aortic valve replacement (TAVR) in aortic regurgitation (AR) patients is relatively low on account of the...
-
The effect of frontal trauma on the edentulous mandible with four different interforaminal implant-prosthodontic anchoring configurations. A 3D finite element analysis
PurposeThe present three-dimensional (3D) finite element analysis (FEA) was aimed to assess the biomechanical effects and fracture risks of four...
-
Left atrial geometry in an ovine ischemic mitral regurgitation model: implications for transcatheter mitral valve replacement devices with a left atrial anchoring mechanism
BackgroundTranscatheter mitral valve replacement (TMVR) is a challenging, but promising minimally invasive treatment option for patients with mitral...
-
Investigation of the appropriate viscosity of fibrinogen in repairing pleural defects using ventilation and anchoring in an ex vivo pig model
ObjectiveOur previous study revealed that the viscosity of fibrinogen could influence the effectiveness of ventilation and anchoring (V/A) methods...
-
Erectile device insertion following phalloplasty in transgender and non-binary individuals assigned female at birth: a narrative review
Genital gender affirmation surgery (gGAS) for individuals assigned female at birth (AFAB) is complex and requires the staged insertion of an erectile...
-
Device-Related Complications Associated with Cylindrical Lead Spinal Cord Stimulator Implants: A Comprehensive Review
Purpose of ReviewSpinal cord stimulation (SCS) is an increasingly utilized therapy for the treatment of neuropathic pain conditions. Though minimally...
-
Concomitant posterior anchoring further reduces posterior meniscal extrusion during pullout repair of medial meniscus posterior root tears: a retrospective study
PurposeTranstibial pullout repair improves the clinical outcomes of medial meniscus (MM) posterior root tears (PRTs); however, reducing MM extrusion...
-
Left atrial appendage closure in a patient previously implanted with an interatrial shunt device: a case report
Patients with previous interatrial shunt device (IASD) implantation may face greater challenges during future left atrial interventional procedures....
-
Embolization of medium-sized vessels with the penumbra occlusion device: evaluation of anchoring function
BackgroundThe penumbra occlusion device (POD) is a recently developed metallic coil with a unique anchor segment. The purpose of this study was to...
-
Primary stability of the Activ L® intervertebral disc prosthesis in cadaver bone and comparison of the keel and spike anchoring concept
BackgroundHigh primary stability is the key prerequisite for safe osseointegration of cementless intervertebral disc prostheses. The aim of our study...
-
The role of magnetic anchoring and traction technique in thoracoscopic lymphadenectomy along the left recurrent laryngeal nerve
BackgroundDissecting lymph nodes along the left recurrent laryngeal nerve (LRLN) is the most challenging step in thoracoscopic-assisted...
-
Develop of endocavitary suction device for MiECC on minimally invasive mitral valve surgery
The minimally invasive extracorporeal circulation (MiECC) system was developed to minimize the contact of blood with air and foreign surfaces during...
-
-
Noctopus: a novel device and method for patient registration and navigation in image-guided cranial surgery
PurposeA patient registration and real-time surgical navigation system and a novel device and method (Noctopus) is presented. With any tracking...
-
Securing CSF catheters to the skin: from sutures and bolt system to subcutaneous anchoring device towards zero complications
IntroductionSecuring the catheter to the skin either with sutures or staples and to the skull with bolt system still represents the most common...
-
Feasibility of contrast-free left atrial appendage closure with WATCHMAN FLX device for patients with chronic kidney disease
Contrast media are generally necessary for transcatheter left atrial appendage closure (LAAC), however, it should be avoided in patients with chronic...
-
An improved method of anchoring chest drain and suture technique for Uni-portal VATS incision
Uni-portal video-assisted thoracoscopic approach is currently a popular surgical technique in general thoracic surgery. After operation, a chest tube...