Search
Search Results
-
Effect of pneumovesicoscopic cohen surgery with adjustable suspension technique through the urethra on the treatment of primary vesicoureteral reflux disease in infants
ObjectiveThe objective of this study was to evaluate the safety and efficacy of pneumovesicoscopic Cohen surgery with an adjustable suspension...
-
Does loop length change after anterior cruciate ligament reconstruction with adjustable loop cortical suspension device?: Observation of the hamstring graft completely filling the femoral tunnel
PurposeThe adjustable loop cortical suspension device (ALD) is a useful femoral fixation device in anterior cruciate ligament (ACL) reconstructions,...
-
Adjustable-loop cortical suspension device for posterolateral corner reconstruction in the setting of fibular avulsion fracture: a case series and novel technique description
IntroductionA novel technique using an adjustable-loop cortical suspension toggle device for reduction of a fibular head avulsion fracture (arcuate...
-
A prospective randomized study of arthroscopic ACL reconstruction with adjustable- versus fixed-loop device for femoral side fixation
PurposeSuspensory devices are extensively used in the management of anterior cruciate ligament (ACL) tear. They include fixed- and adjustable-loop...
-
Additional tying on the adjustable-loop device improves the outcomes of anterior cruciate ligament reconstruction using hamstring autograft
PurposeThe purpose of this study was to verify the efficacy of a novel technique for additional tying on the adjustable-loop device to prevent stress...
-
-
Adjustable Loop Femoral Cortical Suspension Devices for Anterior Cruciate Ligament Reconstruction: A Systematic Review
BackgroundAnterior cruciate ligament (ACL) injury is a common sports injury. Symptomatic knee instability after this injury is usually treated...
-
Suspension button constructs restore posterior knee laxity in solid tibial avulsion of the posterior cruciate ligament
PurposeDislocated tibial avulsions of the posterior cruciate ligament (PCL) require surgical intervention. Several arthroscopic strategies are...
-
Biomechanical testing of fixed and adjustable femoral cortical suspension devices for ACL reconstruction under high loads and extended cyclic loading
PurposeTo compare loop elongation after 5000 cycles, loop-elongation at failure, and load at failure of the fixed-loop G-Lok device and three...
-
Control of the expiratory flow in a lung model and in healthy volunteers with an adjustable flow regulator: a combined bench and randomized crossover study
BackgroundPursed-lips breathing (PLB) is a technique to attenuate small airway collapse by regulating the expiratory flow. During mandatory...
-
ACL hamstring grafts fixed using adjustable cortical suspension in both the femur and tibia demonstrate healing and integration on MRI at one year
PurposeTo present the clinical outcomes and magnetic resonance imaging (MRI) analysis of adjustable cortical suspensory fixation for the femur and...
-
Current trends in graft choice for anterior cruciate ligament reconstruction – part I: anatomy, biomechanics, graft incorporation and fixation
Graft selection in anterior cruciate ligament (ACL) reconstruction is critical, as it remains one of the most easily adjustable factors affecting...
-
Preparation of static training animal models and research status analysis
As a form of Tuina (Chinese therapeutic massage) Qigong exercises and an essential part of exercise therapy, static training has proven clinical...
-
Biomechanical properties of adjustable extracortical graft fixations in ACL reconstruction
BackgroundReliable biomechanical data about the strength of different tibial extracortical graft fixation devices is sparse. This biomechanical study...
-
Correlation Between the Effects of CO2 Laser and Histopathological Analysis in Vocal Cord Lesions: An Observational Study
Lasers are based on the principle of light amplification by empowering atoms to store and emit light in a coherent form. Through their effect on...
-
Complex physical therapy employing self-adjusting garment (ReadyWrap®) in breast cancer-related lymphedema cases in Brazilian women: a protocol for a randomized controlled trial
BackgroundLymphedema is a common complication following breast cancer treatment. The aim of this study is to evaluate the effectiveness of a...
-
Adjustable loop ACL suspension devices demonstrate less reliability in terms of reproducibility and irreversible displacement
PurposeThe aim of this study was to perform a comprehensive biomechanical examination of frequently applied femoral cortical suspension devices,...
-
A Flexible Suspension Technique of Blepharoplasty: Clinical Application and Comparison with Traditional Technique
BackgroundDouble-eyelid blepharoplasty is one of the most popular aesthetic surgeries in China. But the traditional method produces a hidebound...
-
9.4 T static magnetic field ameliorates imatinib mesylate-induced toxicity and depression in mice
Purpose9.4 T magnetic resonance imaging (MRI) has been initially tested on healthy human volunteers, but its future application will benefit more...
-
A Narrative Review of Prosthesis Design Decision Making After Lower-Limb Amputation for Develo** Shared Decision-Making Resources
PurposeThis narrative review explores available information on the process for prosthesis design and factors influencing prosthesis design decision...