We are improving our search experience. To check which content you have full access to, or for advanced search, go back to the old search.

Search

Please fill in this field.

Search Results

Showing 1-20 of 173 results
  1. Dual-mobility tripod cup for revision hip arthroplasty: long-term (five to fourteen years) evaluation of a new generation cementless implant

    Purpose

    The aims of this study were to evaluate the survivorships of a new generation cementless DMC with tripod additional fixation in revision total...

    Aurélien Klein, Maxence Bordes, ... Michel Fessy in International Orthopaedics
    Article 19 March 2024
  2. The influence of HLA genotype on the development of metal hypersensitivity following joint replacement

    Background

    Over five million joint replacements are performed across the world each year. Cobalt chrome (CoCr) components are used in most of these...

    David J. Langton, Rohan M. Bhalekar, ... Antoni V. F. Nargol in Communications Medicine
    Article Open access 24 June 2022
  3. Hypersensitivity to Implanted Metal Devices

    Purpose of Review

    Metal implants play a significant role in modern medicine. This review summarizes the current literature regarding metal implant...

    Ben L. Schwartz, Deeti J. Pithadia, Jennifer K. Chen in Current Dermatology Reports
    Article 31 January 2023
  4. Understanding immune-mediated cobalt/chromium allergy to orthopaedic implants: a meta-synthetic review

    Background

    The frequency of primary joint replacement surgery continues to increase worldwide. While largely considered biologically inert entities,...

    Arnold Chen, Andrew P. Kurmis in Arthroplasty
    Article Open access 02 February 2024
  5. ARMD-Reaktionsmuster bei Kniegelenkendoprothesen

    Background

    There are case descriptions of pronounced peri-implant inflammatory reactions and necrosis in non-infectious knee joint replacements with...

    Niklas Kirchen, Lars Reich, ... Veit Krenn in Der Orthopäde
    Article 09 January 2020
  6. A comparison of the inflammatory host response to particulate debris adjacent to unlocked and locked screws of a growth guidance system for early onset scoliosis

    Purpose

    The SHILLA™ Growth Guidance system is a stainless-steel rod and screw system used for Early Onset Scoliosis which incorporates a unique...

    Jeffrey M. Toth, Felix Ankomah, ... Koki Uno in European Spine Journal
    Article 13 June 2022
  7. Severe metallosis following catastrophic failure of total shoulder arthroplasty — a case report

    Metallosis is an unusual but consequential complication arising from orthopedic hardware implantation, characterized by the deposition of metallic...

    Feyikemi O. Ogunfuwa, Steven Needell, Ryan W. Simovitch in Skeletal Radiology
    Article 18 January 2024
  8. Mid-term clinical and radiographic outcome of metal-on-metal hip resurfacing through an anterolateral approach

    Purpose

    The aim of this retrospective study was to evaluate the medium-term clinical and radiographic results of current generation metal-on-metal...

    D. Regis, G. Lugani, ... B. Magnan in MUSCULOSKELETAL SURGERY
    Article 07 June 2023
  9. Wear debris in metal-on-metal bearings and modular junctions

    Metal-on-metal (MoM) bearing hip arthroplasty saw increasing utilization and peaked in the 1990s and early 2000s. Although the linear and volumetric...

    Cory Knecht, Landon Polakof, ... Stuart B. Goodman in Die Orthopädie
    Article 23 February 2023
  10. Dual Mobility Total Hip Replacements in Young Patients- A Systematic Review

    Background

    There is little consensus on outcomes of dual Mobility total hip replacement (DM-THR) in younger patients. We performed a systematic review...

    Saima Waseem, Daniel T. P. Fong, ... Sarvpreet Singh in Indian Journal of Orthopaedics
    Article 02 January 2023
  11. Do cobalt and chromium blood metal ion levels normalize after revision of failed metal-on-metal total hip replacements?

    Introduction

    Increased cobalt (Co) and chromium (Cr) serum levels are one reason for revision surgery in metal on metal (MoM) total hip arthroplasty...

    Anna Jungwirth-Weinberger, Carola Hanreich, ... Friedrich Boettner in Archives of Orthopaedic and Trauma Surgery
    Article 01 November 2021
  12. A low dislocation rate after revision total hip arthroplasty performed through the anterior approach

    Background

    Dislocation is a major complication in revision total hip arthroplasties. This study aimed to evaluate the dislocation rate, complications,...

    Edward Kahhaleh, Tatiana Charles, ... Marc Jayankura in Arthroplasty
    Article Open access 05 January 2023
  13. Outcome of revision surgery for adverse local tissue reactions in patients with recalled total hip arthroplasty

    Introduction

    Recalls of total hip arthroplasty (THA) implants, including metal-on-metal (MoM) THA and dual taper stems, due to increased risk of...

    Christian Klemt, Sakkadech Limmahakhun, ... Young-Min Kwon in Archives of Orthopaedic and Trauma Surgery
    Article 09 April 2021
  14. The anatomical location of cystic pseudotumors and muscle atrophy in metal-on-metal resurfacing hip arthroplasty is related to the surgical approach used for implantation. A subgroup analyses of a randomized controlled trial

    Background

    Pseudotumors and muscle atrophy have been associated with metal-on-metal (MoM) resurfacing hip arthroplasty (RHA). We aimed to investigate...

    Mette Holm Hjorth, Inger Mechlenburg, ... Maiken Stilling in Archives of Orthopaedic and Trauma Surgery
    Article 21 February 2023
  15. Revision of ASR hip arthroplasty: analysis of two hundred and ninety six recalled patients at seven years

    Purpose

    The aim of this study is to present an algorithm for the evaluation of both symptomatic and asymptomatic patients.

    Methods

    From November 2004...

    Giovanni Benelli, Merildo Maritato, ... Francesco Sasso in International Orthopaedics
    Article 07 September 2018
  16. Radiographic imaging of carbon fiber implants in the appendicular skeleton in orthopedic oncology

    Objective

    Carbon fiber/poly-ether-ether-ketone implants are increasingly being used in orthopedic oncology. An understanding of how to evaluate the...

    Adam Graeber, Sina Habibollahi, ... Santiago Lozano-Calderon in Skeletal Radiology
    Article 28 June 2022
  17. Gelenktumoren: Seltene, aber wichtige Differenzialdiagnosen von malignen und benignen Tumoren sowie Pseudotumoren in der Rheumatologie

    This review article elucidates the differential diagnostics of malignant and benign joint tumors, pseudotumors of the joints and the peri-implant...

    C. Liewen, V. T. Krenn, ... V. Krenn in Zeitschrift für Rheumatologie
    Article 08 December 2020
  18. Metallosis after knee replacement: a review

    Introduction

    Although metallosis is a well-known complication after total hip arthroplasty, little is known about this phenomenon after total (TKA) or...

    Ismail Sahan, Konstantinos Anagnostakos in Archives of Orthopaedic and Trauma Surgery
    Article 26 July 2020
  19. Large Diameter Head in Primary Total Hip Arthroplasty: A Systematic Review

    Introduction

    The literature around use of Large Diameter Heads (LDH) is abundantly available for revision Total Hip Arthroplasty (THA) but is lacking...

    G. Neupane, R. Madhusudhan, ... R. Vaishya in Indian Journal of Orthopaedics
    Article 29 May 2020
  20. Similar clinical and radiographic outcomes after two different hypoallergenic medial unicompartmental knee in patients with metal allergy

    Background

    The purpose in the present study was to compare clinical and radiological outcomes of patients who had undergone a mobile-bearing...

    Riccardo D’Ambrosi, Nicola Ursino, ... Lorenzo Monti in European Journal of Orthopaedic Surgery & Traumatology
    Article 29 May 2022
Did you find what you were looking for? Share feedback.