Search
Search Results
-
Subtrochanteric fracture after femoral neck system of femoral neck fractures: a report of four cases
BackgroundThe femoral neck system (FNS) is commonly used for internal fixation of femoral neck fractures and has shown promising results. However, we...
-
Dynamic compression locking system versus multiple cannulated compression screw for the treatment of femoral neck fractures: a comparative study
BackgroundFemoral neck fractures are one of the problems in clinical treatment. The prognosis is uncertain. Currently, No internal fixation method is...
-
Incidence of postoperative complications in patellar fractures related to different methods of osteosynthesis procedures - a retrospective cohort study
BackgroundPatellar fractures have a comparatively low incidence compared to all fracture frequencies of the musculoskeletal system. However, surgical...
-
The role of the medial buttress plate in the treatment of Pauwels type II and III femoral neck fracture in nonelderly patients: a retrospective study and preliminary results
BackgroundThe purpose of this study was to compare the effectiveness of multiple cannulated screws combined with medial buttress plate or not for the...
-
Role of Biplane Double-Supported Screw Fixation (BDSF) in Management of Fracture Neck Femur and Its Comparison with Conventional CC Screw Fixation
BackgroundThe aim of this study is to evaluate comparative biomechanical fixation provided with the BDSF method with the conventional CC screw...
-
A computed tomography (CT) based morphometric study of superior pubic ramus anatomy among Arabs to determine safe intramedullary pubic rami screw insertion
PurposeTo assess the morphometric variables of the superior pubic ramus in an Arab/ Middle Eastern population to establish a safe pubic screw...
-
Minimally invasive technique for acute fixation and subtalar fusion of displaced intra-articular calcaneus fractures
Displaced intra-articular calcaneus fractures (DIACFs) are difficult injuries to treat and are often encountered by orthopedic surgeons. For DIACFs...
-
Surgical Residents´ Results Seem to be Non-Inferior Comparing to More Experienced Surgeons in Femoral Neck Fracture Osteosynthesis
Purpose of the StudyFemoral neck fracture osteosynthesis is usually performed by using dynamic hip screw (DHS) or multiple parallel cannulated screws...
-
Power-assisted pedicle screws placement: Is it as safe and as effective as manual technique? Narrative review of the literature and our technique
Pedicle screws are the gold standard in spine surgery, allowing a solid tricolumnar fixation which is unmatched by hooks and wires. The freehand...
-
Comparison of the efficacy of posterior-anterior screws, anterior-posterior screws and a posterior-anterior plate in the fixation of posterior malleolar fractures with a fragment size of ≥ 15 and < 15%
BackgroundDifferent fixation methods have been used to treat posterior malleolar fractures (PMFs), but the clinical efficacy of different fixation...
-
Finite element comparative analysis of three different internal fixation methods in the treatment of Pauwels type III femoral neck fractures
BackgroundComparison of 4 cannulated lag screws (3 inverted triangular cannulated screws + anti-rotating screws;4 CLS), dynamic hip...
-
Biomechanical effects of internal fixation with self-lock compression anti-rotation blade for Pauwels type III femoral neck fractures: a comparative finite element analysis
BackgroundSelf-lock compression anti-rotation blade (SCAB) is a novel internal fixation implant for femoral neck fractures (FNF). We conducted this...
-
Evaluating a cutting-edge augmented reality-supported navigation system for spinal instrumentation
ObjectiveDorsal instrumentation using pedicle screws is a standard treatment for multiple spinal pathologies, such as trauma, infection, or...
-
Comparison between screw fixation and plate fixation via sinus tarsi approach for displaced intra-articular calcaneal fractures: a systematic review and meta-analysis
BackgroundOptimal surgical fixation for displaced intra-articular calcaneal fractures (DIACF) remains a subject of debate, particularly regarding the...
-
Union and displacement characteristics following percutaneous screw fixation of superior pubic rami fractures
PurposeTo determine union and displacement metrics following percutaneous screw fixation (antegrade or retrograde) of superior pubic rami fractures.
... -
Reconstruction of massive bone defects after femoral tumor resection using two new-designed 3D-printed intercalary prostheses: a clinical analytic study with the cooperative utilization of multiple technologies
BackgroundTo reconstruct massive bone defects of the femoral diaphysis and proximal end with limited bilateral cortical bone after joint-preserving...
-
Optimizing percutaneous reduction and fixation with guidewire modification in pelvic and acetabular fractures: surgical technique and case series
BackgroundMinimally invasive percutaneous screw fixation for pelvic ring and acetabular fractures has become increasingly popular due to its numerous...
-
Assessment of the outcome of percutaneous pedicle screws in management of degenerative and traumatic dorsal and lumbar pathologies
BackgroundPercutaneous pedicle screw technique is relatively a recent technique that evolved the concept of posterior spinal instrumentation,...
-
Clinical efficiency of operating room-based sliding gantry CT as compared to mobile cone-beam CT-based navigated pedicle screw placement in 853 patients and 6733 screws
PurposeMultiple solutions for navigation-guided pedicle screw placement are available. However, the efficiency with regard to clinical and resource...
-
Real-time three-dimensional fluoroscopy-navigated percutaneous pelvic screw placement for fragility fractures of the pelvis in the hybrid operating room
BackgroundThe prognosis of conservative treatment for fragility fracture of the pelvis (FFP) in the older patients remains poor. Percutaneous pelvic...