We are improving our search experience. To check which content you have full access to, or for advanced search, go back to the old search.

Search

Please fill in this field.

Search Results

Showing 41-60 of 474 results
  1. Deformity progression in congenital posteromedial bowing of the tibia: a report of 44 cases

    Background

    congenital posteromedial bowing of tibia (CPMBT) is a very rare birth defect, characterized by shortened bowed leg and ankle deformity. We...

    Giovanni Luigi Di Gennaro, Giovanni Gallone, ... Giovanni Trisolino in BMC Musculoskeletal Disorders
    Article Open access 03 July 2020
  2. Interest in curves: when the radius of curvature matters in femur fractures. A CT based morphometric study

    Purpose

    In today’s era, fractures of the femur are primarily managed with intramedullary devices. Kee** in mind the anatomical sagittal bow of the...

    Samarth Mittal, Apoorva Kabra, ... Vivek Trikha in European Journal of Orthopaedic Surgery & Traumatology
    Article 25 October 2022
  3. Evaluation and management of atypical femoral fractures: an update of current knowledge

    Atypical femoral fractures are often attributed to the use of anti-resorptive medications such as bisphosphonates (BP). Whilst they have proven...

    O. Pearce, T. Edwards, ... A. Riddick in European Journal of Orthopaedic Surgery & Traumatology
    Article 15 February 2021
  4. Predictability of implant sizes during cruciate-retaining total knee arthroplasty using an image-free hand-held robotic system

    The use of appropriately sized implants is critical for achieving optimal gap balance following total knee arthroplasty (TKA). Inappropriately sized...

    Krishna Kiran Eachempati, Apurve Parameswaran, ... Neil P. Sheth in Journal of Robotic Surgery
    Article 03 February 2024
  5. Flexible versus standard intramedullary rod in posterior stabilized primary total knee arthroplasty: protocol for a randomized controlled trial

    Background

    In total knee arthroplasty (TKA) a flexible intramedullary rod can be used to account for sagittal bowing of the distal femur. Although...

    M. R. Bénard, R. F. M. van Doremalen, ... P. J. C. Heesterbeek in Journal of Orthopaedic Surgery and Research
    Article Open access 14 October 2020
  6. Comparison of the radiographic outcomes and total blood loss between pinless navigation and conventional method in minimally invasive total knee arthroplasty

    Background

    Computer-assisted surgical navigation has been used in total knee arthroplasty (TKA) procedures for years trying to the accuracy of...

    Shih-Hsiang Yen, Po-Chun Lin, Jun-Wen Wang in Journal of Orthopaedic Surgery and Research
    Article Open access 28 March 2023
  7. Morphological changes in the superficial medial collateral ligament on knee MR imaging: association with medial meniscal extrusion and posterior root medial meniscus abnormality

    Objective

    To assess the association between morphological changes in the superficial medial collateral ligament and meniscal extrusion with medial...

    So ** Yoon, Joong Mo Ahn, ... Heung-Sik Kang in Skeletal Radiology
    Article 16 December 2021
  8. Population-based, three-dimensional analysis of age- and sex-related femur shaft geometry differences

    Summary

    This study deals with differences of femoral geometric focus on the bowing and width. Analysis using three-dimensional skeletonization showed...

    I. J. Jung, E. J. Choi, ... J. W. Kim in Osteoporosis International
    Article 26 January 2021
  9. Robot-assisted total knee arthroplasty improves mechanical alignment and accuracy of component positioning compared to the conventional technique

    Purpose

    The purpose of this study was to compare the mechanical axis, accuracy of component positioning, and polyethylene liner thickness between...

    Chang Hyun Nam, Su Chan Lee, ... Ji-Hoon Baek in Journal of Experimental Orthopaedics
    Article Open access 28 October 2022
  10. Seven phenotypes of varus osteoarthritic knees can be identified in the coronal plane

    Purpose

    Recommendations for resecting distal femur and proximal tibia in mechanical and anatomical alignment techniques are standardized. Kinematic...

    Arun Mullaji, Rahul Shah, ... Harshad Thakur in Knee Surgery, Sports Traumatology, Arthroscopy
    Article 20 July 2021
  11. Specific tibial landmarks to improve to accuracy of the tibial cut during total knee arthroplasty. A case control study

    Introduction

    More personalized alignment techniques in total knee arthroplasty (TKA) have recently been described particularly for the young and...

    Sébastien Parratte, Zakee Azmi, ... Cécile Batailler in Archives of Orthopaedic and Trauma Surgery
    Article 05 July 2024
  12. The effect of patient positioning on measurements of bone mineral density of the proximal femur: a simulation study using computed tomographic images

    Summary

    The patient’s position may affect the bone mineral density (BMD) measurements; however, the extent of this effect is undefined. This CT...

    Keisuke Uemura, Masaki Takao, ... Nobuhiko Sugano in Archives of Osteoporosis
    Article 24 February 2023
  13. The Role of Lower-Limb Geometry in the Pathophysiology of Atypical Femoral Fracture

    Purposeof Review

    The etiology of atypical femoral fracture (AFF) is likely multifactorial. In this review, we examined the recent literature...

    Ifaz T. Haider, Prism S. Schneider, W. Brent Edwards in Current Osteoporosis Reports
    Article 13 August 2019
  14. Accuracy in the Execution of Pre-operative Plan for Limb Alignment and Implant Positioning in Robotic-arm Assisted Total Knee Arthroplasty and Manual Total Knee Arthroplasty: A Prospective Observational Study

    Aim

    The objective of the study is to compare the accuracy of implant positioning and limb alignment achieved in robotic-arm assisted total knee...

    Jai Thilak, Balu C. Babu, ... Greeshma C. Ravindran in Indian Journal of Orthopaedics
    Article 04 January 2021
  15. Knieendoprothetik – individuell angepasste Prothesen

    Women more frequently experience osteoarthritis of the knee than men, but they often undergo conservative treatments for an extended period and are...

    Sebastian Braun, Moses K. D. El Kayali, ... Clemens Gwinner in Knie Journal
    Article 17 June 2024
  16. Quadriceps tendon malalignment is an independent anatomical deformity which is the primary abnormality associated with lateral facet patellofemoral joint osteoarthritis

    Purpose

    The purposes of this study are to, firstly, develop techniques to accurately identify extensor mechanism malalignment by measuring the...

    Simon Talbot, Rachel Zordan, ... William L. Walter in Knee Surgery, Sports Traumatology, Arthroscopy
    Article 21 November 2023
  17. Determining the rotational alignment of the tibial component referring to the tibial tubercle during total knee arthroplasty: the tibial tubercle–trochlear groove can be an aid

    Background

    There is no consensus on anatomic landmarks or reference axes with which to accurately align rotational position of tibial component. Using...

    He Zhang, Chengming Cao, ... Shoujiang Han in Journal of Orthopaedic Surgery and Research
    Article Open access 04 May 2022
  18. Exploration of the fetal skeleton by ultra-low-dose computed tomography: guidelines from the Fetal Imaging Task Force of the European Society of Paediatric Radiology

    Skeletal anomalies are rare, requiring a systematic ultrasound (US) examination of each skeletal part when there is suspicion of a skeletal...

    Pascale Bach, Marie Cassart, ... Michel Panuel in Pediatric Radiology
    Article 27 August 2022
  19. Percutaneous image-guided treatment of mucoid degeneration of the ACL in advanced knee osteoarthritis—Preliminary observations

    Objectives

    To describe the percutaneous image-guided treatment of mucoid degeneration of the ACL causing deep knee pain on flexion in patients with...

    Sarah Kate Eustace, John Hynes, ... Stephen Eustace in Irish Journal of Medical Science (1971 -)
    Article 13 February 2024
  20. Femoral flexion position is a highly variable factor in total knee arthroplasty: an analysis of 593 conventionally aligned total knee replacements

    Purpose

    In contrast to coronal alignment, only few is known about sagittal alignment in total knee arthroplasty (TKA). The aim of this study was to...

    Paola Koenen, Deha Murat Ates, ... Holger Bäthis in Knee Surgery, Sports Traumatology, Arthroscopy
    Article 27 May 2019
Did you find what you were looking for? Share feedback.