Page
%P
![Loading...](https://link.springer.com/static/c4a417b97a76cc2980e3c25e2271af3129e08bbe/images/pdf-preview/spacer.gif)
-
Article
Inductively coupled plasma mass spectrometry for the sequential determination of trace metals in sea water after electrothermal vaporization of their dithiocarbamate complexes in methyl isobutyl ketone
A sensitive method has been developed for the sequential determination of V, Mn, Fe, Co, Ni, Cu, Zn, Mo and Sb in sea water using inductively coupled plasma mass spectrometry (ICP-MS) after electrothermal vap...
-
Article
Sensitive Method for the Selective Determination of Selenium(IV) and Selenium(VI) in Natural Water hy High-Performance Liquid Chromatography with a Spectrofluorometric Detector
A sensitive method for the selective determination of selenium(IV) and selenium(VI) in natural water using reversed-phase high-performance liquid chromatography with a spectrofluorometric detector has been dev...