Skip to main content

and
  1. Article

    Open Access

    Accuracy of patient-specific I-131 dosimetry using hybrid whole-body planar-SPECT/CT I-123 and I-131 imaging

    This study aimed to assess the accuracy of patient-specific absorbed dose calculations for tumours and organs at risk in radiopharmaceutical therapy planning, utilizing hybrid planar-SPECT/CT imaging.

    Michaella Morphis, Johan A. van Staden, Hanlie du Raan, Michael Ljungberg in EJNMMI Physics (2024)

  2. Article

    Open Access

    3D printed non-uniform anthropomorphic phantoms for quantitative SPECT

    A 3D printing grid-based method was developed to construct anthropomorphic phantoms with non-uniform activity distributions, to be used for evaluation of quantitative SPECT images. The aims were to characteriz...

    Lovisa Jessen, Johan Gustafsson, Michael Ljungberg, Selma Curkic-Kapidzic in EJNMMI Physics (2024)

  3. Article

    Open Access

    Feasibility of 177Lu activity quantification using a small portable CZT-based gamma-camera

    In image processing for activity quantification, the end goal is to produce a metric that is independent of the measurement geometry. Photon attenuation needs to be accounted for and can be accomplished utiliz...

    Daniel Roth, Erik Larsson, Joanna Strand, Michael Ljungberg in EJNMMI Physics (2024)

  4. Article

    Open Access

    On the use of solid 133Ba sources as surrogate for liquid 131I in SPECT/CT calibration: a European multi-centre evaluation

    Commissioning, calibration, and quality control procedures for nuclear medicine imaging systems are typically performed using hollow containers filled with radionuclide solutions. This leads to multiple source...

    Johannes Tran-Gia, Ana M. Denis-Bacelar, Kelley M. Ferreira in EJNMMI Physics (2023)

  5. Article

    Open Access

    Machine learning-based prediction of conversion coefficients for I-123 metaiodobenzylguanidine heart-to-mediastinum ratio

    We developed a method of standardizing the heart-to-mediastinal ratio in 123I-labeled meta-iodobenzylguanidine (MIBG) images using a conversion coefficient derived from a dedicated phantom. This study aimed to cr...

    Koichi Okuda, Kenichi Nakajima, Chiemi Kitamura in Journal of Nuclear Cardiology (2023)

  6. Article

    Open Access

    Phase II trial demonstrates the efficacy and safety of individualized, dosimetry-based 177Lu-DOTATATE treatment of NET patients

    Radionuclide therapy with 177Lu-DOTATATE is well established for patients with advanced somatostatin receptor–positive neuroendocrine tumors with a standard schedule of 7.4 GBq at four occasions. However, this ap...

    Anna Sundlöv, Katarina Sjögreen Gleisner in European Journal of Nuclear Medicine and M… (2022)

  7. Article

    Open Access

    Monte Carlo modelling of a compact CZT-based gamma camera with application to 177Lu imaging

    Semiconductor gamma-camera systems based on cadmium zinc telluride (CZT) detectors present new challenges due to an energy-response that includes effects of low-energy tailing. In particular, such energy tails...

    Daniel Roth, Erik Larsson, Michael Ljungberg, Katarina Sjögreen Gleisner in EJNMMI Physics (2022)

  8. Article

    Open Access

    Evaluation of Iodine-123 and Iodine-131 SPECT activity quantification: a Monte Carlo study

    The quantitative accuracy of Nuclear Medicine images, acquired for both planar and SPECT studies, is influenced by the isotope-collimator combination as well as image corrections incorporated in the iterative ...

    Michaella Morphis, Johan A. van Staden, Hanlie du Raan, Michael Ljungberg in EJNMMI Physics (2021)

  9. Article

    Open Access

    A multicentre and multi-national evaluation of the accuracy of quantitative Lu-177 SPECT/CT imaging performed within the MRTDosimetry project

    Patient-specific dosimetry is required to ensure the safety of molecular radiotherapy and to predict response. Dosimetry involves several steps, the first of which is the determination of the activity of the r...

    Johannes Tran-Gia, Ana M. Denis-Bacelar, Kelley M. Ferreira in EJNMMI Physics (2021)

  10. No Access

    Chapter

    Quantitative SPECT Imaging

    A scintillation camera is essentially a device that measures two-dimensional (2D) images of a radionuclide distribution in vivo by detecting emitted photons. Due to the construction of the collimator, events i...

    Michael Ljungberg in Basic Sciences of Nuclear Medicine (2021)

  11. Article

    Open Access

    Feasibility of simplifying renal dosimetry in 177Lu peptide receptor radionuclide therapy

    Recently, 177Lu-dotatate therapy for neuroendocrine tumours has received regulatory approval. Dosimetry can be used to optimize treatment on an individual basis, but there is no international consensus as to how ...

    Anna Sundlöv, Johan Gustafsson, Gustav Brolin, Nadja Mortensen in EJNMMI Physics (2018)

  12. Article

    Open Access

    Monte Carlo-based quantitative pinhole SPECT reconstruction using a ray-tracing back-projector

    Monte Carlo simulations provide accurate models of nuclear medicine imaging systems as they can properly account for the full physics of photon transport. The accuracy of the model included in the maximum-like...

    Mikael Peterson, Johan Gustafsson, Michael Ljungberg in EJNMMI Physics (2017)

  13. Article

    Open Access

    Individualised 177Lu-DOTATATE treatment of neuroendocrine tumours based on kidney dosimetry

    To present data from an interim analysis of a Phase II trial designed to determine the feasibility, safety, and efficacy of individualising treatment based on renal dosimetry, by giving as many cycles as possi...

    Anna Sundlöv, Katarina Sjögreen-Gleisner in European Journal of Nuclear Medicine and M… (2017)

  14. Article

    Open Access

    EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision

    Since the publication of the European Association of Nuclear Medicine (EANM) procedural guidelines for radionuclide myocardial perfusion imaging (MPI) in 2005, many small and some larger steps of progress have...

    Hein J. Verberne, Wanda Acampa in European Journal of Nuclear Medicine and M… (2015)

  15. Article

    Open Access

    Evaluation of inter-departmental variability of ejection fraction and cardiac volumes in myocardial perfusion scintigraphy using simulated data

    Myocardial perfusion scintigraphy (MPS) is a clinically useful noninvasive imaging modality for diagnosing patients with suspected coronary artery disease. By utilizing gated MPS, the end diastolic volume (EDV...

    Elin Trägårdh, Michael Ljungberg, Lars Edenbrandt, Eva Örndahl in EJNMMI Physics (2015)

  16. No Access

    Chapter

    Quantitative SPECT Imaging

    The scintillation camera is essentially a device that measures 2D images of a radionuclide distribution in vivo by detecting emitted photons. Due to the construction of the collimator, events in the image comi...

    Michael Ljungberg in Basic Sciences of Nuclear Medicine (2011)

  17. No Access

    Article

    Monte Carlo evaluation of object shape effects in iodine-131 SPET tumor activity quantification

    In our clinical iodine-131 single-photon emission tomography (SPET) quantification for radioimmunotherapy, calibration and partial volume correction are based on measurements with phantoms containing spheres ...

    Yuni K. Dewaraja, Michael Ljungberg in European Journal of Nuclear Medicine (2001)

  18. No Access

    Article

    Evaluation of optimally designed planar-concave collimators in single-photon emission tomography

    The imaging properties of optimally designed planar-concave (PC) collimators were evaluated by means of Monte Carlo simulations. The evaluation was done with respect to total system spatial resolution and the ...

    Shahrok Kimiaei, Michael Ljungberg, Stig A. Larsson in European Journal of Nuclear Medicine (1997)

  19. No Access

    Chapter and Conference Paper

    Registration of abdominal CT and SPECT images using Compton scatter data

    The present study investigates the possibility to utilize Compton scatter data for registration of abdominal SPECT images. A method for registration to CT is presented, based on principal component analysis an...

    Katarina Sjögreen, Michael Ljungberg in Information Processing in Medical Imaging (1997)

  20. No Access

    Article

    Quantitative SPECT by attenuation correction of the projection set using transmission data: evaluation of a method

    A method for measuring attenuation coefficients in single-photon emission tomography (SPECT) is described and evaluated, together with a method for attenuation correction using these measured attenuation coeff...

    Helén Almquist, John Palmer, Michael Ljungberg in European Journal of Nuclear Medicine (1990)