Log in

Power consumption and energy efficiency of VRF system based on large scale monitoring virtual sensors

  • Research Article
  • Building Systems and Components
  • Published:
Building Simulation Aims and scope Submit manuscript

Abstract

Space cooling energy consumption is a significant component of building energy consumption, and in recent years it has attracted much attention worldwide owing to its significantly increasing usage. The variable refrigerant flow (VRF) system is one common type of cooling equipment for buildings in China and is applied extensively to residential and office buildings. The performance of VRF systems significantly influences the cooling energy consumption of buildings. The system energy efficiency and electricity consumption are the main indicators employed to evaluate the performance of VRF systems. It is hard to obtain the actual energy efficiency and electricity consumption of VRF systems in buildings because of the high cost of the required complicated measurements. This study proposes a virtual sensor modeling method to determine the actual energy efficiency and electricity consumption of 344 VRF systems in residential buildings. Statistical and clustering analyses are conducted to determine the energy efficiency and electricity consumption to obtain distributions and typical operation load patterns of VRF systems in residential buildings in China. The main findings are as follows: the main range of the Seasonal Energy Efficiency Ratio (SEER) for the cooling season is from 2.9 to 4.4; the median SEER in the Hot Summer and Cold Winter zone is lower than in another climate zones; the longer cooling duration may lead to greater electricity consumption, and the electricity load for VRF systems electricity load is periodic for each day. The oversizing issue is common for VRF systems in the dataset, which also led to the lower energy efficiency of VRF systems. The high usage of VRF systems appeared from July 27th to August 26th. The findings provide recommendations for designing VRF systems in residential buildings.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price includes VAT (Germany)

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Alonso S, Morán A, Pérez D, Reguera P, Díaz I, Domínguez M (2019). Virtual sensor based on a deep learning approach for estimating efficiency in chillers. In: Proceedings of International Conference on Engineering Applications of Neural Networks.

  • An J, Yan D, Hong T (2018). Clustering and statistical analyses of air-conditioning intensity and use patterns in residential buildings. Energy and Buildings, 174: 214–227.

    Article  Google Scholar 

  • Capozzoli A, Piscitelli MS, Gorrino A, Ballarini I, Corrado V (2017). Data analytics for occupancy pattern learning to reduce the energy consumption of HVAC systems in office buildings. Sustainable Cities and Society, 35: 191–208.

    Article  Google Scholar 

  • Cetin KS, Novoselac A (2015). Single and multi-family residential central all-air HVAC system operational characteristics in cooling-dominated climate. Energy and Buildings, 96: 210–220.

    Article  Google Scholar 

  • Chandra Putra H, Andrews CJ, Senick JA (2017). An agent-based model of building occupant behavior during load shedding. Building Simulation, 10: 845–859.

    Article  Google Scholar 

  • Chetty G, White M, Akther F (2015). Smart phone based data mining for human activity recognition. Procedia Computer Science, 46: 1181–1187.

    Article  Google Scholar 

  • Chua KJ, Chou SK, Yang WM, Yan J (2013). Achieving better energy-efficient air conditioning—A review of technologies and strategies. Applied Energy, 104: 87–104.

    Article  Google Scholar 

  • Chung W (2011). Review of building energy-use performance benchmarking methodologies. Applied Energy, 88: 1470–1479.

    Article  Google Scholar 

  • D’Oca S, Hong T (2015). Occupancy schedules learning process through a data mining framework. Energy and Buildings, 88: 395–408.

    Article  Google Scholar 

  • Davies DL, Bouldin DW (1979). A cluster separation measure. IEEE Transactions on Pattern Analysis and Machine Intelligence, PAMI-1: 224–227.

    Article  Google Scholar 

  • Dong B, Lam KP (2014). A real-time model predictive control for building heating and cooling systems based on the occupancy behavior pattern detection and local weather forecasting. Building Simulation, 7: 89–106.

    Article  Google Scholar 

  • Duarte C, van den Wymelenberg K, Rieger C (2013). Revealing occupancy patterns in an office building through the use of occupancy sensor data. Energy and Buildings, 67: 587–595.

    Article  Google Scholar 

  • Fan C, **ao F (2018). Mining big building operational data for improving building energy efficiency: A case study. Building Services Engineering Research and Technology, 39: 117–128.

    Article  Google Scholar 

  • Fan C, **ao F, Li Z, Wang J (2018). Unsupervised data analytics in mining big building operational data for energy efficiency enhancement: A review. Energy and Buildings, 159: 296–308.

    Article  Google Scholar 

  • Fan C, **ao F, Song M, Wang J (2019). A graph mining-based methodology for discovering and visualizing high-level knowledge for building energy management. Applied Energy, 251: 113395.

    Article  Google Scholar 

  • Goffart J, Woloszyn M, Faure X, Wurtz F, Gondian L, et al. (2019). Overview of a large scale monitoring project of energy positive houses: complementarity between simulations and measurements. In: Proceeidngs of International IBPSA Building Simulation Conference, Rome, Italy.

  • Guo Y, Li G, Chen H, Hu Y, Shen L, et al. (2017). Development of a virtual variable-speed compressor power sensor for variable refrigerant flow air conditioning system. International Journal of Refrigeration, 74: 73–85.

    Article  Google Scholar 

  • Han J, Pei J, Kamber M (2011). Data Mining: Concepts and Techniques. New York: Elsevier.

    MATH  Google Scholar 

  • Hong T, Sun K, Zhang R, Hinokuma R, Kasahara S, Yura Y (2016). Development and validation of a new variable refrigerant flow system model in EnergyPlus. Energy and Buildings, 117: 399–411.

    Article  Google Scholar 

  • Hou Z, Lian Z, Yao Y, Yuan X (2006). Data mining based sensor fault diagnosis and validation for building air conditioning system. Energy Conversion and Management, 47: 2479–2490.

    Article  Google Scholar 

  • Hu S, Yan D, An J, Guo S, Qian M (2019). Investigation and analysis of Chinese residential building occupancy with large-scale questionnaire surveys. Energy and Buildings, 193: 289–304.

    Article  Google Scholar 

  • HVACHOME (2018). China Central Air Conditioning Industry Research Report. (in Chinese)

  • IEA (2018). The Future of Cooling. International Energy Agency.

  • Kim H, Stumpf A, Kim W (2011). Analysis of an energy efficient building design through data mining approach. Automation in Construction, 20: 37–43.

    Article  Google Scholar 

  • Kim J, Lee J, Choi H, Lee S, Oh S, Park W-G (2015). Experimental study of R134a/R410A cascade cycle for variable refrigerant flow heat pump systems. Journal of Mechanical Science and Technology, 29: 5447–5458.

    Article  Google Scholar 

  • Kusiak A, Li M (2010). Cooling output optimization of an air handling unit. Applied Energy, 87: 901–909.

    Article  Google Scholar 

  • Kwon L, Hwang Y, Radermacher R, Kim B (2012). Field performance measurements of a VRF system with sub-cooler in educational offices for the cooling season. Energy and Buildings, 49: 300–305.

    Article  Google Scholar 

  • Li G, Hu Y, Chen H, Li H, Hu M, et al. (2017). Data partitioning and association mining for identifying VRF energy consumption patterns under various part loads and refrigerant charge conditions. Applied Energy, 185: 846–861.

    Article  Google Scholar 

  • Liu J, Wang J, Li G, Chen H, Shen L, **ng L (2017). Evaluation of the energy performance of variable refrigerant flow systems using dynamic energy benchmarks based on data mining techniques. Applied Energy, 208: 522–539.

    Article  Google Scholar 

  • Liu J, Liu J, Chen H, Huang R, Li Z, et al. (2019). Abnormal energy identification of variable refrigerant flow air-conditioning systems based on data mining techniques. Applied Thermal Engineering, 150: 398–411.

    Article  Google Scholar 

  • Mathew PA, Dunn LN, Sohn MD, Mercado A, Custudio C, Walter T (2015). Big-data for building energy performance: Lessons from assembling a very large national database of building energy use. Applied Energy, 140: 85–93.

    Article  Google Scholar 

  • Meesrikamolkul W, Niennattrakul V, Ratanamahatana CA (2012). Shape-based clustering for time series data. In: Proceedings of the Pacific-Asia Conference on Knowledge Discovery and Data Mining.

  • Miller C, Meggers F (2017). The Building Data Genome Project: An open, public data set from non-residential building electrical meters. Energy Procedia, 122: 439–444.

    Article  Google Scholar 

  • Mirakhorli A, Dong B (2017). Occupant-behavior driven appliance scheduling for residential buildings. Building Simulation, 10: 917–931.

    Article  Google Scholar 

  • Muroni A, Gaetani I, Hoes P-J, Hensen JLM (2019). Occupant behavior in identical residential buildings: A case study for occupancy profiles extraction and application to building performance simulation. Building Simulation, 12: 1047–1061.

    Article  Google Scholar 

  • Naug A, Biswas G (2018). A data driven method for prediction of energy demand in commercial buildings. In: Proceedings of IEEE 14th International Conference on Automation Science and Engineering (CASE), Munich, Germany.

  • Noussan M, Nastasi B (2018). Data analysis of heating systems for buildings—A tool for energy planning, policies and systems simulation. Energies, 11: 233.

    Article  Google Scholar 

  • Yan D, Hong T, Dong B, Mahdavi A, D’Oca S, Gaetani I, Feng X (2017). IEA EBC Annex 66: Definition and simulation of occupant behavior in buildings. Energy and Buildings, 156: 258–270.

    Article  Google Scholar 

  • Yu Z, Fung BCM, Haghighat F (2013). Extracting knowledge from building-related data—A data mining framework. Building Simulation, 6: 207–222.

    Article  Google Scholar 

  • Yu X, Yan D, Sun K, Hong T, Zhu D (2016). Comparative study of the cooling energy performance of variable refrigerant flow systems and variable air volume systems in office buildings. Applied Energy, 183: 725–736.

    Article  Google Scholar 

  • Yun GY, Lee JH, Kim HJ (2016). Development and application of the load responsive control of the evaporating temperature in a VRF system for cooling energy savings. Energy and Buildings, 116: 638–645.

    Article  Google Scholar 

  • Zhang R, Sun K, Hong T, Yura Y, Hinokuma R (2018). A novel Variable Refrigerant Flow (VRF) heat recovery system model: Development and validation. Energy and Buildings, 168: 399–412.

    Article  Google Scholar 

  • Zhang G, Li X, Shi W, Wang B, Cao Y (2019). Influence of occupant behavior on the energy performance of variable refrigerant flow systems for office buildings: A case study. Journal of Building Engineering, 22: 327–334.

    Article  Google Scholar 

  • Zhao D, Zhong M, Zhang X, Su X (2016). Energy consumption predicting model of VRV (Variable refrigerant volume) system in office buildings based on data mining. Energy, 102: 660–668.

    Article  Google Scholar 

  • Zou H, Zhou Y, Jiang H, Chien S-C, **e L, Spanos CJ (2018). WinLight: A WiFi-based occupancy-driven lighting control system for smart building. Energy and Buildings, 158: 924–938.

    Article  Google Scholar 

Download references

Acknowledgements

The project was supported by the State Key Laboratory of Air-Conditioning Equipment and System Energy Conservation (ACSKL2018KT16).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Da Yan.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Qian, M., Yan, D., Liu, H. et al. Power consumption and energy efficiency of VRF system based on large scale monitoring virtual sensors. Build. Simul. 13, 1145–1156 (2020). https://doi.org/10.1007/s12273-020-0670-x

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12273-020-0670-x

Keywords

Navigation