Abstract
In this work, a new procedure using extraction induced by emulsion breaking (EIEB) procedure has been developed for extraction/preconcentration of cadmium in various edible oils (canola, corn, hazelnut, olive, and sunflower oil) prior to its determination by flow injection (FI) flame atomic absorption spectrometry (FAAS). Five chemical variables (surfactant type, concentration of the surfactant, concentration of the nitric acid, emulsion breaking time, and temperature) were selected as the main factors affecting extraction efficiency, and two variables (sample flow rate and sample volume) were studied for optimizing flow injection conditions. The limits of detection of 1.53 and 1.55 μg L−1 were observed for cadmium when aqueous standard and oil-based standards were added to the samples for calibration, respectively. The linear range of cadmium in aqueous standard was varied in the range of 5.9–94 μg L−1. The precision of the EIEB procedure was obtained as 4.1 % by determination of ten replicates of 2.5 μg L−1 of cadmium, and the preconcentration factor 13.8 was obtained from only 4 mL of edible oil samples. The accuracy of the procedure was performed by comparison with the reference method based on the digestion of samples in a closed-vessel microwave oven and by spiking the samples with the known amounts of the cadmium in the form of oil-based standards. There were no statistical differences between the results obtained with the EIEB procedure and the reference microwave digestion method, and the recoveries were in the range of 97–104 %.
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs12161-015-0112-z/MediaObjects/12161_2015_112_Fig1_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs12161-015-0112-z/MediaObjects/12161_2015_112_Fig2_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs12161-015-0112-z/MediaObjects/12161_2015_112_Fig3_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs12161-015-0112-z/MediaObjects/12161_2015_112_Fig4_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs12161-015-0112-z/MediaObjects/12161_2015_112_Fig5_HTML.gif)
Similar content being viewed by others
References
Andruch V, Balogh IS, Kocurova L, Sandrejova J (2013) The present state of coupling of dispersive liquid-liquid microextraction with atomic absorption spectrometry. J Anal At Spectrom 28:19–32
Anthemidis AN, Arvanitidis V, Stratis JA (2005) On-line emulsion formation and multi-element analysis of edible oils by inductively coupled plasma atomic emission spectrometry. Anal Chim Acta 537:271–278
Aucelio RQ, de Souza RM, de Campos RC, Miekeley N, da Silveira CLP (2007) The determination of trace metals in lubricating oils by atomic spectrometry. Spectrochim Acta B 62:952–961
Bakircioglu D, Topraksever N, Kurtulus YB (2014) Determination of zinc in edible oils by flow injection FAAS after extraction induced by emulsion breaking procedure. Food Chem 151:219–224
Burguera JL, Burguera M (2011) Pretreatment of oily samples for analysis by flow injection spectrometric methods. Talanta 83:691–699
Burguera JL, Burguera M (2012) Analytical applications of emulsions and microemulsions. Talanta 96:11–20
Cabrera C, Lloris F, Gimenez R, Olalla M, Lopez MC (2003) Mineral content in legumes and nuts: contribution to the Spanish dietary intake. Sci Total Environ 308:1–14
Caldas LFS, Brum DM, de Paula CER, Cassella RJ (2013) Application of the extraction induced by emulsion breaking for the determination of Cu, Fe and Mn in used lubricating oils by flame atomic absorption spectrometry. Talanta 110:21–27
Cassella RJ, Brum DM, de Paula CER, Lima CF (2010) Extraction induced by emulsion breaking: a novel strategy for the trace metals determination in diesel oil samples by electrothermal atomic absorption spectrometry. J Anal At Spectrom 25:1704–1711
Cassella RJ, Brum DM, Lima CF, Caldas LFS, de Paula CER (2011) Multivariate optimization of the determination of zinc in diesel oil employing a novel extraction strategy based on emulsion breaking. Anal Chim Acta 690:79–85
Cassella RJ, Brum DM, Robaina NF, Rocha AA, Lima CF (2012) Extraction induced by emulsion breaking for metals determination in diesel oil by ICP-MS. J Anal At Spectrom 27:364–370
Chang YT, Jiang SJ (2008) Determination of As, Cd and Hg in emulsified vegetable oil by flow injection chemical vapour generation inductively coupled plasma mass spectrometry. J Anal At Spectrom 23:140–144
de Souza RM, da Silveira CLP, Aucelio RQ (2004) Determination of refractory elements in used lubricating oil by ICPOES employing emulsified sample introduction and calibration with inorganic standards. Anal Sci 20:351–355
de Souza RM, Mathias BM, da Silveira CLP, Aucelio RQ (2005) Inductively coupled plasma optical emission spectrometry for trace multi-element determination in vegetable oils, margarine and butter after stabilization with propan-1-ol and water. Spectrochim Acta B 60:711–715
Diaz TG, Guiberteau A, Lopez Soto MD, Ortiz JM (2006) Determination of copper with 5, 5-dimethylcyclohexane-1, 2, 3-trione 1, 2-dioxime 3-thiosemicarbazone in olive oils by adsorptive strip** square wave voltammetry. Food Chem 96:156–162
Garcia P, Romero C, Brenes M, Garrido A (2002) Validation of a method for the analysis of iron and manganese in table olives by flame atomic absorption spectrometry. J Agric Food Chem 50:3654–3659
He YM, Chen JJ, Zhou Y, Wang XJ, Liu XY (2014) Extraction induced by emulsion breaking for trace multi-element determination in edible vegetable oil by ICP-MS. Anal Methods 6:5105–5111
Jamali MK, Kazi TG, Arain MB, Afridi HI, Jalbani N, Sarfraz RA, Baig JA (2008) A multivariate study: variation in uptake of trace and toxic elements by various varieties of Sorghum bicolor. J Hazard Mater 158:644–651
Jimenez MS, Lopez A, Castillo JR (2002) Automatic emulsion formation as a sample introduction system for GFAAS determination of iron in edible oil and mineral oils. At Spectrosc 23:183–189
Karadjova I, Zachariadis G, Boskou G, Stratis J (1998) Electrothermal atomic absorption spectrometric determination of aluminium, cadmium, chromium, copper, iron, manganese, nickel and lead in olive oil. J Anal At Spectrom 13:201–204
Lepri FG, Chaves ES, Vieira MA, Ribeiro AS, Curtius AJ, de Oliveira LCC, de Campos RC (2011) Determination of trace elements in vegetable oils and biodiesel by atomic spectrometric techniques—a review. Appl Spectrosc Rev 46:175–206
Mendil D, Uluozlu OD, Tuzen M, Soylak M (2009) Investigation of the levels of some element in edible oil samples produced in turkey by atomic absorption spectrometry. J Hazard Mater 165:724–728
Robaina NF, Brum DM, Cassella RJ (2012) Application of the extraction induced by emulsion breaking for the determination of chromium and manganese in edible oils by electrothermal atomic absorption spectrometry. Talanta 99:104–112
Salager JL, Anton RE (1999) In: Kumar P, Mittal KL (eds) Handbook of microemulsion science and technology. Dekker, New York, Chapter 8
Zeiner M, Steffan I, Cindric IJ (2005) Determination of trace elements in olive oil by ICP-AES and ETA-AAS: a pilot study on the geographical characterization. Microchem J 81:171–176
Zhu F, Fan W, Wang X, Qu L, Yao S (2011) Health risk assessment of eight metals in nine varieties of edible vegetable oils consumed in China. Food Chem Toxicol 49:3081–3085
Acknowledgments
The authors are grateful to Trakya University (TUBAP-2012/114) for financial support.
Conflict of Interest
Authors do not have a financial relationship with the organization that sponsored the research. Nukte Topraksever declares that she has no conflict of interest. Yasemin Bakircioglu Kurtulus declares that she has no conflict of interest. This article does not contain any studies with human or animal subjects.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Bakircioglu, D., Topraksever, N. & Kurtulus, Y.B. Separation/Preconcentration System Based on Emulsion-Induced Breaking Procedure for Determination of Cadmium in Edible Oil Samples by Flow Injection-Flame Atomic Absorption Spectrometry. Food Anal. Methods 8, 2178–2184 (2015). https://doi.org/10.1007/s12161-015-0112-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12161-015-0112-z