Abstract
In endurance time (ET) method structures are subjected to a set of predesigned intensifying excitations. These excitations are produced in a way that their response spectrum, while complying with a specified spectrum, intensifies with time so they can be used approximately to simulate the average effects of several ground motions scaled to different intensities. In this paper applicability of the ET method for evaluating collapse potential of buildings is investigated. A set of four steel moment frames is used for collapse assessment. The process of using ET method in collapse evaluation is explained and the results are compared with incremental dynamic analysis (IDA) results. It is shown that although the computational effort using the ET method is much less than the IDA analysis, the results of both methods are consistent. Finally collapse fragility curves using ET and IDA methods are produced and it is shown that the probabilities of collapse in different hazard levels are also consistent.
Similar content being viewed by others
References
Adam C, Ibarra LF and Krawinkler H (2004), “Evaluation of P-Delta Effects in Non-deteriorating MDOF Structures from Equivalent SDOF Systems,” Proceedings of 13th World Conference on Earthquake Engineering, Vancouver, B.C., Canada, Paper ID. 3407.
AISC (2010), Seismic Provisions for Structural Steel Buildings, (ANSI/AISC 341–10), American Institute of Steel Construction, Chicago, Illinois 60601–1802.
AISC (2010), Specification for Structural Steel Buildings, (ANSI/AISC 360-10), American Institute of Steel Construction, Chicago, Illinois 60601–1802.
Alembagheri M and Estekanchi HE (2011), “Seismic Assessment of Unanchored Steel Storage Tanks by Endurance Time Method,” Earthquake Engineering and Engineering Vibration, 10(4): 591–603.
ASCE (2010), Minimum Design Loads for Buildings and Other Structures, (ASCE 7–10), American Society of Civil Engineers New York (NY).
Barkhordary M and Tariverdilo S (2011), “Vulnerability of Ordinary Moment Resistant Concrete Frames,” Earthquake Engineering and Engineering Vibration, 10(4): 519–533.
Bernal D (1987), “Amplification Factors for Inelastic P-Δ Effects in Earthquake Analysis,” Earthquake Engineering & Structural Dynamics, 15(5): 635–651.
Estekanchi HE, Riahi HT and Vafai A (2009), “Endurance Time Method: Exercise Test Applied To Structures,” Asian Journal of Civil Engineering (Building And Housing), 10(5): 559–577.
Estekanchi HE, Valamanesh V and Vafai A (2007), “Application of Endurance Time Method in Linear Seismic Analysis,” Engineering Structures, 29: 2551–2562.
ET records (2013), Retrieved March 24, 2013 from https://sites.google.com/site/etmethod/.
FEMA (2000), Prestandard and Commentary for the Seismic Rehabilitation of Buildings, Publ. No. 356, prepared by the American Society of Civil Engineers for the Federal Emergency Management Agency, Washington, D.C.
FEMA P695 (2009), Quantification of Building Seismic Performance Factors, Federal Emergency Management Agency, Washington, D.C.
FEMA 355F (2000), State of the Art Report on Performance Prediction and Evaluation of Steel Momentframe Buildings, Federal Emergency Management Agency, Washington, D.C.
Han SW and Chopra AK (2006), “Approximate Incremental Dynamic Analysis Using The modal Pushover Analysis Procedure,” Earthquake Engineering & Structural Dynamic, 35(15):1853–1873.
Han SW, Moon KH and Chopra AK (2010), “Application of MPA to Estimate Probability of Collapse of Structures,” Earthquake Engineering & Structural Dynamic, 39:1259–1278.
Haselton CB and Baker JW (2006), “Ground Motion Intensity Measures for Collapse Capacity Prediction: Choice of Optimal Spectral Period and Effect of Spectral Shape,” Proceedings of 8th National Conference on Earthquake Engineering, San Francisco, California. Retrieved July 29, 2013 from http://www.stanford.edu/~bakerjw/Publications/Haselton%20Baker%20(2006)%208NCEE%20record%20selection.pdf.
Haselton CB and Deierlein GG (2007), “Assessing Seismic Collapse Safety of Modern Reinforced Concrete Moment-Frame Buildings,” PEER Report no. 2007/08. Berkeley (CA): Pacific Earthquake Engineering Research Center, University of California.
Ibarra LF and Krawinkler H (2005), “Global Collapse of Frame Structures under Seismic Excitations,” PEER Report no. 2005/06. Berkeley (CA): Pacific Earthquake Engineering Research Center, University of California.
Ibarra L.F, Medina RA and Krawinkler H (2005), “Hysteretic Models that Incorporate Strength and Stiffness Deterioration,” Earthquake Engineering & Structural Dynamics, 34(12): 1489–1511.
Kim J and Kim T (2009), “Assessment of Progressive Collapse-Resisting Capacity of Steel Moment Frames,” Constructional Steel Research, 65:169–179.
Lignos DG and Krawinkler H (2009), “Sideway Collapse of Deteriorating Structural Systems under Seismic Excitations,” Report No. TB 172. Stanford (CA): John A. Blume Earthquake Engineering Research Center. Department of Civil and Environmental Engineering, Stanford University.
Liu M (2011), “Progressive Collapse Design of Seismic Steel Frames Using Structural Optimization,” Constructional Steel Research, 67: 322–332.
Miranda E and Akkar D (2003), “Dynamic Instability of Simple Structural Systems,” Structural Engineering 129(12): 1722–6.
Mirzaee A and Estekanchi HE (2013) “Performancebased Seismic Retrofitting of Steel Frames by Endurance Time Method,” Earthquake Spectra, DOI:10.1193/081312EQS262M.
OpenSees (2002), Open System for Earthquake Engineering Simulation, Pacific Earthquake Engineering Research Center, http://peer.berkeley.edu/.
Riahi HT and Estekanchi HE (2010), “Seismic Assessment of Steel Frames with the Endurance Time Method,” Constructional Steel Research, 66: 780–792.
Shafei B, Zareian F and Lignos DG (2011), “A Simplified Method for Collapse Capacity Assessment of Momentresisting Frame and Shear Wall Structural Systems,” Engineering Structures, 33: 1107–1116.
Takizawa H and Jennings P (1980), “Collapse of a Model for Ductile Reinforced Concrete Frames under Extreme Earthquake Motions,” Earthquake Engineering & Structural Dynamics, 8(2): 117–144.
Tang B, Lu X, Ye L, Shi W (2011), “Evaluation of Collapse Resistance of RC Frame Structures for Chinese Schools in Seismic Design Categories B and C,” Earthquake Engineering and Engineering Vibration, 10(3): 369–377.
Valamanesh V and Estekanchi H.E (2010a), “A Study of Endurance Time Method In The Analysis of Elastic Moment Frames Under Three-Directional Seismic Loading,” Asian Journal of Civil Engineering (Building And Housing) 11(5): 543–562.
Valamanesh V and Estekanchi H.E (2010b), “Characteristics of Second Generation Endurance Time Acceleration Functions,” Scientia Iranica, 11(1): 53–61.
Vamvatsikos D and Cornell CA (2002), “Incremental Dynamic Analysis,” Earthquake Engineering & Structural Dynamic, 31(3): 491–514.
Villaverde R (2007), “Methods to Assess The Seismic Collapse Capacity of Building Structures,” State of the Art. Structural Engineering, 133(1): 57–66.
Williamson EB (2003), “Evaluation of Damage and P–Delta effects for Systems under Earthquake Excitation,” Structural Engineering, 129(8): 1036–46.
Zareian F and Krawinkler H (2007), “Assessment of Probability of Collapse and Design for Collapse Safety,” Earthquake Engineering & Structural Dynamic, 36(13): 1901–14.
Zareian F and Krawinkler H (2009), “Simplified Performance-based Earthquake Engineering,” Report No. TB 169 Stanford (CA): John A. Blume Earthquake Engineering Research Center. Department of Civil and Environmental Engineering, Stanford University.
Zareian F, Krawinkler H, Ibarra L and Lignos D (2010), “Basic Concepts and Performance Measures in Prediction of Collapse of Buildings under Earthquake Ground Motions,” The Structural Design of Tall And Special Buildings, 19: 167–181.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Rahimi, E., Estekanchi, H.E. Collapse assessment of steel moment frames using endurance time method. Earthq. Eng. Eng. Vib. 14, 347–360 (2015). https://doi.org/10.1007/s11803-015-0027-0
Received:
Accepted:
Published:
Issue Date: