Log in

Differential pulse anodic strip** voltammetric determination of Hg2+ at poly(Eriochrome Black T)-modified carbon paste electrode

  • Original Paper
  • Published:
Ionics Aims and scope Submit manuscript

Abstract

The electrochemical behavior of Hg2+ was investigated in poly(Eriochrome Black T)-modified carbon paste electrode (CPE) using cyclic voltammetry (CV). Poly(Eriochrome Black T) was prepared in an alkaline medium on the surface of the CPE using a solution of Eriochrome Black T with the CV technique. The electrochemical impedance study revealed a better charge transfer kinetics at the modified electrode. The effects of variation of the experimental conditions, such as the concentration of electrolytes, pH, deposition time, and the deposition potential, which maximize current efficiency were studied. The optimum response of Hg2+ was observed in 1.0 M KCl solution. The differential pulse anodic strip** voltammetric technique was employed successfully to detect Hg2+, which gave a good linear response at low concentration levels of Hg2+. The detection limit was found to be 2.2 × 10−10 M (S/N = 3), which is comparable with that achieved in multiwall carbon nanotube-modified electrode. The remarkable electroanalytical performance of the modified electrode makes it amenable to employ it successfully as an electrochemical sensor for the determination of hazardous pollutant Hg2+ in environmental samples.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
EUR 32.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or Ebook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Scheme 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7

Similar content being viewed by others

References

  1. Huang W, Yang C, Zhang S (2002) Anodic strip** voltammetric determination of mercury by use of a sodium montmorillonite modified carbon paste electrode. Anal Bioanal Chem 374:998–1001. doi:10.1007/s00216-002-1438-0

    Article  CAS  Google Scholar 

  2. Fitzgerald WF, Lamborg CH (2004) Geochemistry of mercury in the environment. In: Holland HD, Turekian KK (eds) Treatise on geochemistry. Elsevier, Amsterdam, pp 107–148. doi:10.1016/B0-08-043751-6/09048-4

  3. Safavi A, Farjami E (2011) Construction of carbon nanocomposite electrode based on amino acid functionalized gold nanoparticles for trace electrochemical detection of mercury. Anal Chim Acta 688:43–48. doi:10.1016/j.aca.2010.12.001

    Article  CAS  Google Scholar 

  4. Park SM, Choi HS (2002) Sensitized spectrophotometric determination of trace Hg(II) in benzalkonium chloride media. Anal Chim Acta 459:75–81. doi:10.1016/S0003-2670(02)00103-4

    Article  CAS  Google Scholar 

  5. Nguyen TH, Bomann J, Leermakers M, Baeyens W (1998) Mercury analysis in environmental samples by EDXRF and CV-AAS. Fresenius J Anal Chem 360:199–204. doi:10.1007/s002160050674

    Article  CAS  Google Scholar 

  6. Bowles KC, Apte SC (1998) Determination of methylmercury in natural water samples by steam distillation and gas chromatography–atomic fluorescence spectrometry. Anal Chem 70:395–399. doi:10.1021/ac970826s

    Article  CAS  Google Scholar 

  7. Debrah E, Denoyer ER, Tyson JF (1996) Flow injection determination of mercury with preconcentration by amalgamation on gold–platinum gauze by inductively coupled plasma mass spectrometry. J Anal Atom Spectrum 11:127–132. doi:10.1039/JA9961100127

    Article  CAS  Google Scholar 

  8. Bruce J (2003) Analysis of mercury in waters using voltammetry. Int Labmate 28:9–11

    Google Scholar 

  9. Jena BK, Raj CR (2008) Gold nanoelectrode ensembles for the simultaneous electrochemical detection of ultratrace arsenic, mercury and copper. Anal Chem 80:4836–4844. doi:10.1021/ac071064w

    Article  CAS  Google Scholar 

  10. Turyan I, Mandler D (1994) Electrochemical determination of ultralow levels (<10−12 M) by anodic strip** voltammetry using a chemically modified electrode. Electroanalysis 6:838–843. doi:10.1002/elan.1140061005

    Article  CAS  Google Scholar 

  11. Faller C, Stojko N, Henze G, Brainina KZ (1999) Strip** voltammetric determination of mercury at modified solid electrodes: determination of mercury traces using PDC/Au(III) modified electrodes. Anal Chim Acta 396:195–202. doi:10.1016/S0003-2670(99)00434-1

    Article  CAS  Google Scholar 

  12. Abollino O, Giacomo A, Malandrino M, Piscionieri G, Mentasti E (2008) Determination of mercury by anodic strip** voltammetry with a gold nanoparticle-modified glassy carbon electrode. Electroanalysis 20:75–83. doi:10.1002/elan.200704044

    Article  CAS  Google Scholar 

  13. Navaratilova Z, Zula P (1992) Determination of mercury on a carbon paste electrode modified with humic acid. Electroanalysis 4:683–687. doi:10.1002/elan.1140040703

    Article  Google Scholar 

  14. Zen J, Chung M (1995) Square wave strip** voltammetric analysis of mercury(II) at poly(4-vinylpyridine)/gold film electrode. Anal Chem 67:3571–3577. doi:10.1021/ac00115a029

    Article  CAS  Google Scholar 

  15. Buica GO, Bucher C, Moutet J, Royal G, Saint-Aman E, Ungureanu EL (2009) Voltammetric sensing of mercury and copper cations at poly(EDTA-like) film modified electrode. Electroanalysis 21:77–86. doi:10.1002/elan.200804386

    Article  CAS  Google Scholar 

  16. Cheng KC, Chen PY (2008) Polyviologen modified glassy carbon electrode employed for anodic strip** voltammetric determination of mercury(II). Electroanalysis 20:207–210. doi:10.1002/elan.200704041

    Article  CAS  Google Scholar 

  17. Zelji H, Sharrock P, de Cisneros JLHH, Naranjo- Rodriguez I, Temsamani KR (2005) Voltammetric determination of trace mercury at a sonogel–carbon electrode modified with poly-3-methylthiophene. Talanta 68:79–85. doi:10.1016/j.talanta.2005.04.060

    Article  Google Scholar 

  18. Roy PR, Okajima T, Ohsaka T (2003) Simultaneous electroanalysis of dopamine and ascorbic acid using poly(N,N-dimethylaniline) modified electrodes. Bioelectrochemistry 59:11–19. doi:10.1016/S1567-5394(02)00156-1

    Article  CAS  Google Scholar 

  19. Manjunatha JG, Swamy BEK, Mamatha GP, Shankar S, Gilbert O, Chandrashekar BN, Sherigara BS (2010) Electrochemical studies of dopamine and epinephrine at a poly(tannic acid) modified carbon paste electrode: a cyclic voltammetric study. Int J Electrochem Sci 5:1236–1245

    CAS  Google Scholar 

  20. Thomas T, Mascarenhas RJ, Nethravathi C, Rajamathi M, Swamy BEK (2011) Graphite oxide bulk modified carbon paste electrode for the selective detection of dopamine: a voltammetric study. J Electroanal Chem 659:113–119. doi:10.1016/j.jelechem.2011.05.011

    Article  CAS  Google Scholar 

  21. Thomas T, Mascarenhas RJ, Swamy BEK (2012) Poly(rhodamine B) modified carbon paste electrode for the selective detection of dopamine. J Mol Liq 174:70–75. doi:10.1016/j.molliq.2012.07.022

    Article  CAS  Google Scholar 

  22. Thomas T, Mascarenhas RJ, Cotta F, Sri Guha K, Swamy BEK, Martis P, Mekhalif Z (2013) Poly(Patton and Reeder’s reagent) modified carbon paste electrode for the sensitive detection of acetaminophen in biological fluid and pharmaceutical formulations. Colloids Surf B 101:91–96. doi:10.1016/j.colsurfb.2012.06.020

    Article  CAS  Google Scholar 

  23. Sherigara BS, Shivaraj Y, Mascarenhas RJ, Satpati AK (2007) Simultaneous determination of lead, copper and cadmium onto mercury film supported on wax impregnated carbon paste electrode: assessment of quantification procedures by anodic strip** voltammetry. Electrochim Acta 52:3137–3142. doi:10.1016/j.electacta.2006.09.055

    Article  CAS  Google Scholar 

  24. Mascarenhas RJ, Satpati AK, Yellappa S, Sherigara BS, Bopiah AK (2006) Wax-impregnated carbon paste electrode modified with mercuric oxalate for the simultaneous determination of heavy metal ions in medicinal plants and ayurvedic tablets. Anal Sci 22:871–875. doi:10.2116/analsci.22.871

    Article  CAS  Google Scholar 

  25. Yao H, Sun Y, Lin X, Tang Y, Huang L (2007) Electrochemical characterization of poly(Eriochrome Black T) modified glassy carbon electrode and its application to simultaneous determination of dopamine, ascorbic acid and uric acid. Electrochim Acta 52:6165–6171. doi:10.1016/j.electacta.2007.04.013

    Article  CAS  Google Scholar 

  26. Yao H, Sun Y, Lin X, Tang Y, Liu A, Li G, Li W, Zhang S (2007) Selective determination epinephrine in the presence of ascorbic acid and uric acid by electrocatalytic oxidation at poly(Eriochrome Black T) film modified glassy carbon electrode. Anal Sci 23:677–682. doi:10.2116/analsci.23.677

    Article  CAS  Google Scholar 

  27. Sharp M, Petersson M, Edström K (1979) Preliminary determinations of electron transfer kinetics involving ferrocene covalently attached to a platinum surface. J Electroanal Chem 95:123–130. doi:10.1016/S0022-0728(79)80227-2

    Article  CAS  Google Scholar 

  28. Bott AW (1995) Voltammetric determination of trace concentration of metals in the environment. Curr Sep 14:24–30

    CAS  Google Scholar 

  29. Pontie M, Sikpo L, Thouand G, Lahan R, Tapsoba I, Mallet R, Feng T (2011) Direct electroanalysis of p-nitrophenol (PNP) in estuarine and surface waters by a high sensitive type C/p-NiTSPc coating carbon fiber microelectrode (CFME). Electroanalysis 2:433–441. doi:10.1002/elan.201000384

    Article  Google Scholar 

  30. Lin Y, Lu F, Wang J (2004) Disposable carbon nanotube modified screen printed biosensor for amperometric detection of organophosphorous pesticides and nerve agents. Electroanalysis 16:145–149. doi:10.1002/elan.200302933

    Article  CAS  Google Scholar 

  31. Skoog DA, West DM, Holler FJ, Crouch SR (2003) Fundamentals of analytical chemistry. Cengage, USA

    Google Scholar 

  32. Wang J, Bonakdar M (1988) Preconcentration and voltammetric measurement of mercury with a crown ether modified carbon paste electrode. Talanta 35:277–280. doi:10.1016/0039-9140(88)80085-7

    Article  CAS  Google Scholar 

  33. Švancara I, Vytrˇas K (1992) Voltammetric determination of mercury(II) at a carbon paste electrode in aqueous solutions containing tetraphenylborate ion. Talanta 39:391–396. doi:10.1016/0039-9140(92)80153-5

    Article  Google Scholar 

  34. Yi H (2003) Anodic strip** voltammetric determination of mercury using multi-walled carbon nanotubes film coated glassy carbon electrode. Anal Bioanal Chem 377:770–774. doi:10.1007/s00216-003-2136-2

    Article  CAS  Google Scholar 

  35. Kiekens P, Mertens M, Bogaert M, Temmerman E (1984) Determination of mercury by anodic strip** voltammetry using a glassy carbon rotating disc electrode. Analyst 109:909–911. doi:10.1039/AN9840900909

    Article  CAS  Google Scholar 

  36. Korolezuk M (1997) Sensitive and selective determination of mercury by differential pulse strip** voltammetry after accumulation of mercury vapor on a gold plated graphite electrode. Fresenius J Anal Chem 357:389–391. doi:10.1007/s002160050175

    Article  Google Scholar 

Download references

Acknowledgments

The authors are grateful for the financial support given by the University Grants Commission, New Delhi of India, under the Major Research Project No. UGC. F.No.38-232/2009 (SR) to carry out the present research work. The authors also thank Dr. Suresh of SSMRV College, Bangalore, for providing the EIS facility.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ronald J. Mascarenhas.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Guha, K.S., Mascarenhas, R.J., Thomas, T. et al. Differential pulse anodic strip** voltammetric determination of Hg2+ at poly(Eriochrome Black T)-modified carbon paste electrode. Ionics 20, 849–856 (2014). https://doi.org/10.1007/s11581-013-1040-9

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11581-013-1040-9

Keywords

Navigation