Non-invasive cardiac output evaluation during a maximal progressive exercise test, using a new impedance cardiograph device

  • Original Article
  • Published:
European Journal of Applied Physiology Aims and scope Submit manuscript

Abstract.

One of the greatest challenges in exercise physiology is to develop a valid, reliable, non-invasive and affordable measurement of cardiac output (CO). The purpose of this study was to evaluate the reproducibility and accuracy of a new impedance cardiograph device, the Physio Flow, during a 1-min step incremental exercise test from rest to maximal peak effort. A group of 12 subjects was evaluated to determine the reproducibility of the method as follows: (1) each subject performed two comparable tests while their CO was measured by impedance cardiography using the new device (COImp1, COImp2), and (2) in a subgroup of 7 subjects CO was also determined by the direct Fick method (COFick) during the second test. The mean difference between the values obtained by impedance (i.e. COImp1–COImp2) was –0.009 l·min–1 (95% confidence interval: –4.2 l·min–1, 4.2 l·min–1), and CO ranged from 3.55 l·min–1 to 26.75 l·min–1 (n=146). When expressed as a percentage, the difference (COImp1–COImp2) did not vary with increasing CO. The correlation coefficient between the values of COImp and COFick obtained during the second exercise test was r=0.94 (P<0.01, n=50). The mean difference expressed as percentage was –2.78% (95% confidence interval: –27.44%, 21.78%). We conclude that COImp provides a clinically acceptable evaluation of CO in healthy subjects during an incremental exercise.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
EUR 32.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or Ebook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price includes VAT (Germany)

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Richard, R., Lonsdorfer-Wolf, E., Charloux, A. et al. Non-invasive cardiac output evaluation during a maximal progressive exercise test, using a new impedance cardiograph device. Eur J Appl Physiol 85, 202–207 (2001). https://doi.org/10.1007/s004210100458

Download citation

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s004210100458

Navigation