Abstract
We report on a case of a patient who had femoral osteolysis and severe metallosis of the knee joint resulting from the secondary abrasive wear of the metal-backed tibial component of a unicompartmental knee arthroplasty due to massive wear of tibial polyethylene. The failure was diagnosed 11 years after implantation. This metallosis affected the intra-articular tissues and the subchondral bone.
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00167-006-0207-6/MediaObjects/167_2006_207_Fig1_HTML.jpg)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00167-006-0207-6/MediaObjects/167_2006_207_Fig2_HTML.jpg)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00167-006-0207-6/MediaObjects/167_2006_207_Fig3_HTML.jpg)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00167-006-0207-6/MediaObjects/167_2006_207_Fig4_HTML.jpg)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00167-006-0207-6/MediaObjects/167_2006_207_Fig5_HTML.jpg)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00167-006-0207-6/MediaObjects/167_2006_207_Fig6_HTML.jpg)
Similar content being viewed by others
References
Bartley RE, Stulberg SD, Robb WJ, Sweeney HJ (1994) Polyethylene wear in unicompartmental knee arthroplasty. Clin Orthop Relat Res 299:18–24
Berry DJ, Wold LE, Rand JA (1993) Extensive osteolysis around an aseptic, stable, uncemented total knee replacement. Clin Orthop Relat Res 293:204–207
Christensen OM, Christiansen TG, Johansen T (1990) Polyethylene failure in a PCA unicompartmental knee prosthesis. Acta Orthop Scand 61:578–579
Crawford R, Sabokbar A, Wulke A, Murray DW, Athanasou NA (1998) Expansion of an osteoarthritic cyst associated with wear debris. A case report. J. Bone Joint Surg 80-B:900–903
Engh GA, Dwyer KA, Hanes CK (1992) Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prostheses. J Bone Joint Surg 74-B:9–17
Engh GA, Ammeen D (2004) Is an intact anterior cruciate ligament needed in order to have a well-functioning unicondylar knee replacement? Clin Orthop Relat Res 428:170–173
Gross TP, Lennox DW (1992) Osteolytic cyst-like area associated with polyethylene and metallic debris after total knee preplacement with an uncemented vitallium prosthesis. A case report. J Bone Joint Surg 74-A:1096–1101
Hart R, Janecek M, Bucek B (2003) Case report of extensive metallosis in extra-articular tissues after unicompartmental knee joint replacement. Acta Chir Orthop Traumatol Cech 70:47–50
Kadoya Y, Kobayashi A, Ohashi H (1998) Wear and osteolysis in total joint replacements. Acta Orthop Scand Suppl 278:1–16
Keblish PA (1997) The case for unicompartmental knee arthroplasty. Orthopedics 17:853–855
Kim KJ, Kobayashi Y, Itoh T (1998) Osteolysis model with continuous infusion of polyethylene particles. Clin Orthop Relat Res 352:46–52
Lindstrand A, Stenstrom A (1992) Polyethylene wear of the PCA unicompartmental knee. Prospective 5 (4–8) year study of 120 arthrosis knees. Acta Orthop Scand 63:260–262
Mc Govern TF, Moskal JT (2002) Radiographic evaluation of periprosthetic metallosis after total knee arthroplasty. J South Orthop Assoc 11:18–24
Merritt K, Brown SA (1996) Distribution of cobalt chromium wear and corrosion products and biologic reactions. Clin Orthop Relat Res 329:S233–243
Murray DW, Goodfellow JW, O’Connor JJ (1998) The Oxford medial unicompartmental arthroplasty. A ten-year survival study. J Bone Joint Surg 80-B:983–989
Ollivierre FM, Mike Malek M (2001) Overview of complications of total knee arthroplasty. In: Mike Malek M (eds) Knee surgery. complications, pitfalls and salvage. Springer, New York pp 303–351
Ottaviani G, Catagni MA, Matturri L (2005) Massive metallosis due to metal-on-metal im**ement in substitutive long-stemmed knee prosthesis. Histopathology 46:237–238
Palmer SH, Morrison PJ, Ross AC (1998) Early catastrophic tibial component wear after unicompartmental knee arthroplasty. Clin Orthop Relat Res 350:143–148
Pandit H, Beard DJ, Jenkins C, Kimstra Y, Thomas NP, Dodd CA, Murray DW (2006) Combined anterior cruciate ligament reconstruction and Oxford unicompartmental knee arthroplasty. J Bone Joint Surg 88-B:887–892
Psychoyios V, Crawford RW, O’Connor JJ (1998) Wear of congruent meniscal bearings in unicompartmental knee arthroplasty. A retrieval study of 16 specimens. J Bone Joint Surg 80-B:976–982
Rolf O, Baumann B, Sterner T, Schutze N, Jakob F, Eulert J, Rader CP (2005) Characterization of mode II-wear particles and cytokine response in a human macrophage-like cell culture. Biomed Tech 50:25–29
Sanchis-Alfonso V, Alcacer-García J (2001) Extensive osteolytic cistlike area associated with polyethylene wear debris adjacent to an aseptic, stable, uncemented unicompartmental knee prosthesis: case report. Knee Surg Sports Traumatol Arthosc 9:173–177
Suggs JF, mLi G, Park SE, Sultan PG, Rubash HE, Freiberg AA (2006) Knee biomechanics after UKA and its relation to the ACL. A robotic investigation. J Orthop Res 24:588–594
Whiteside LA (1997) Polyethylene, osteolysis, and total joint replacement. Am J Knee Surg 10:243
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Sanchis-Alfonso, V. Severe metallosis after unicompartmental knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 15, 361–364 (2007). https://doi.org/10.1007/s00167-006-0207-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00167-006-0207-6