Experimental and Numerical Investigation on Fouling and Heat Transfer Performance of a Novel H-type Finned Heat Exchanger

  • Conference paper
  • First Online:
Advances in Heat Transfer and Thermal Engineering
  • 2511 Accesses

Abstract

In this paper, the fouling and convection heat transfer characteristics of various flue gas heat exchangers are investigated, and the weakening degrees of fouling on the heat transfer performance of different heat exchangers are compared. The anti-fouling performance of novel H-type finned tube heat exchangers are discussed. The results show that the elliptical tube arrangement can effectively reduce the effect of fouling on heat transfer performance. Overall, SHETB has the best heat transfer and anti-fouling performance. The results of this paper are helpful for the efficient recovery and utilization of dusty flue gas waste heat.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Subscribe and save

Springer+ Basic
EUR 32.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or Ebook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free ship** worldwide - see info
Hardcover Book
USD 219.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free ship** worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Similar content being viewed by others

References

  1. M.J. Li, S.Z. Tang, F.L. Wang et al., Gas-side fouling, erosion and corrosion of heat exchangers for middle/low temperature waste heat utilization: a review on simulation and experiment. Appl. Therm. Eng. 126, 737–761 (2017)

    Article  Google Scholar 

  2. A. Nuntaphan, T. Kiatsiriroat, Thermal behavior of spiral fin-and-tube heat exchanger having fly ash deposit. Exp. Therm. Fluid Sci. 31, 1103–1109 (2007)

    Article  Google Scholar 

  3. Y.T. Shi, M. Gao, G.H. Tang, F.Z. Sun, W.Q. Tao, Experimental research of CFB ash deposition on helical finned tubes. Appl. Therm. Eng. 37, 420–429 (2012)

    Article  Google Scholar 

  4. F.L. Wang, S.Z. Tang, Y.L. He, F.A. Kulacki, Y. Yu, Heat transfer and fouling performance of finned tube heat exchangers: experimentation via on line monitoring. Fuel 236, 949–959 (2019)

    Article  Google Scholar 

Download references

Acknowledgements

The present work is supported by the National Key R&D Program of China (2018YFB0605901).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ming-Jia Li .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2021 Springer Nature Singapore Pte Ltd.

About this paper

Check for updates. Verify currency and authenticity via CrossMark

Cite this paper

Tang, SZ., Liu, ZB., Li, MJ., Tao, WQ. (2021). Experimental and Numerical Investigation on Fouling and Heat Transfer Performance of a Novel H-type Finned Heat Exchanger. In: Wen, C., Yan, Y. (eds) Advances in Heat Transfer and Thermal Engineering . Springer, Singapore. https://doi.org/10.1007/978-981-33-4765-6_108

Download citation

  • DOI: https://doi.org/10.1007/978-981-33-4765-6_108

  • Published:

  • Publisher Name: Springer, Singapore

  • Print ISBN: 978-981-33-4764-9

  • Online ISBN: 978-981-33-4765-6

  • eBook Packages: EngineeringEngineering (R0)

Publish with us

Policies and ethics

Navigation