Abstract
Previous studies on seismic performance of large-scale liquefied natural gas (LNG) storage tanks mainly focused on the horizontal earthquake excitations. However, vertical earthquake actions may lead to structural damage, overturning and even failure of a liquid storage tank, especially under near-fault earthquakes. In this study, aiming to investigate seismic behavior of the inner tank of a large-scale LNG storage tank subjected to vertical earthquakes, a shaking table test of a 1:25 scaled steel tank with full-filled liquid was carried out. Vertical components of El Centro waves, Chi-Chi 1529 waves and Chi-Chi 1505 waves were selected as input, representing near-field earthquakes, near-fault earthquakes without and with vertical velocity pulse, respectively. Seismic responses, including the sloshing wave height, hydrodynamic pressure and stress on the tank wall were obtained and analyzed. Results showed that the sloshing wave height under Chi-Chi waves was 1.2 ~ 2.5 times larger than that under El Centro waves. In comparison with El Centro waves with the peak ground acceleration (PGA) of 0.26 g, the peak hydrodynamic pressure increased by 10 and 36% under Chi-Chi 1529 waves and Chi-Chi 1505 waves, respectively. In addition, the vertical velocity pulse contained in near-fault earthquakes significantly amplified the stress on tank wall. For instance, the hoop and axial stress were increased by 269.12 and 63.50% at most under the excitations of Chi-Chi 1529 waves, respectively. Dynamic responses of liquid under vertical near-fault earthquakes were greater than that under near-field earthquakes, especially under the near-fault earthquakes with vertical velocity pulse.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Bae, D., Park, J.H.: Shaking table test of steel cylindrical liquid storage tank considering the roof characteristics. Int. J. Steel Struct. 18(4), 1167–1176 (2018)
Burkacki, D., Jankowski, R.: Experimental study on steel tank model using shaking table. Civil Environ. Eng. Rep. 14(3), 37–47 (2014)
Chiba, M., Tani, J., Hashimoto, H., Sudo, S.: Dynamic stability of liquid-filled cylindrical shells under horizontal excitation, Part I: experiment. J. Sound Vibr. 104(2), 301–319 (1986)
Etsuo, S., Masaaki, N., Kouji, Y.: Experimental study on the steady response of the large thin-walled cylindrical liquid storage tank model excited by the sinusoidal wave. J. High-Pressure Inst. Japan 21(1), 39–47 (1983)
Fang, Z., Chen, Z., Yan, S., Cao, G., Wang, J.: Dynamic experimental investigation on the uplift response of liquid storage tanks under seismic excitations with different characteristics. Proc. Inst. Mech. Eng. Part C J. Mech. Eng. Sci. 227(7), 1525–1534 (2013)
Hamdan, F.H.: Seismic behaviour of cylindrical steel liquid storage tanks. J. Constr. Steel Res. 53(3), 307–333 (2000)
Haroun, M.A., Tayel, M.A.: Response of tanks to vertical seismic excitations. Earthq. Eng. Struct. Dyn. 13(5), 583–595 (1985)
Haroun, M.A., Abdel-Hafiz, E.A.: A simplified seismic analysis of rigid base liquid storage tanks under vertical excitation with soil-structure interaction. Soil Dyn. Earthq. Eng. 5(4), 217–225 (1986)
Haroun, M.A., Abou-Izzeddine, W.: Parametric study of seismic soil-tank interaction. I: Horizontal excitation. J. Struct. Eng. 118(3), 783–797 (1992a)
Haroun, M. A. & Abou-Izzeddine, W., (1992b), Parametric Study of Seismic Soil-Tank Interaction. II: Vertical Excitation, Journal of Structural Engineering, 118 (3), 798 – 811
Kianoush, M.R., Chen, J.Z.: Effect of vertical acceleration on response of concrete rectangular liquid storage tanks. Eng. Struct. 28(5), 704–715 (2006)
Kianoush, M.R., Ghaemmaghami, A.R.: The effect of earthquake frequency content on the seismic behavior of concrete rectangular liquid tanks using the finite element method incorporating soil-structure interaction. Eng. Struct. 33(7), 2186–2200 (2011)
Li, H.H., Zhao, W., Wang, W.: Dynamic response of a 100,000 m3 cylindrical oil-storage tank under seismic excitations: experimental tests and numerical simulations. Shock Vibr. 8, 2074946.1–2074946.19 (2018)
Lu, L., Lu, X.: Study of dynamic similitude law for the shaking table test to cancel the gravity distortion effect. Struct. Eng. 4(008), 45–48 (2001). (in Chinese)
Maekawa, A., Shimizu, Y., Suzuki, M., Fujita, K.: Vibration test of a 1/10 reduced scale model of cylindrical water storage tank. J. Pressure Vessel Technol. 132(5), 051–801 (2004)
Ministry of Housing and Urban-Rural Development of the People’s Republic of China: Standard for Test Method of Mechanical Properties on Ordinary Concrete, GBT 500081-2002. Architecture & Building Press, Bei**g (China) (2003)
Ministry of Housing and Urban-Rural Development of the People’s Republic of China: Dimension, Shape, Weight and Tolerances for Hot-Rolled Steel Plates and Sheets, GB/T 709-2006. Architecture & Building Press, Bei**g (China) (2006)
Ministry of Housing and Urban-Rural Development of the People’s Republic of China: Metallic Materials–Tensile Testing–Part 1: Method of Test at Room Temperature, GB/T 228.1-2010. Architecture & Building Press, Bei**g (China) (2010)
Ormeño, M., Larkin, T., Chouw, N.: Experimental study of the effect of a flexible base on the seismic response of a liquid storage tank. Thin-Walled Struct. 139, 334–346 (2019)
Park, J.H., Bae, D., Oh, C.K.: Experimental study on the dynamic behavior of a cylindrical liquid storage tank subjected to seismic excitation. Int. J. Steel Struct. 16(3), 935–945 (2016). https://doi.org/10.1007/s13296-016-0172-y
Rötzer, J.: Design and Construction of LNG Storage Tanks. Wiley, New York, USA (2019)
Shih, C.: Failure of liquid storage tanks due to earthquake excitation. California Institute of Technology (1981)
Veletsos, A.S., Yu, T.: Dynamics of vertically excited liquid storage tanks. J. Struct. Eng. 112(6), 1228–1246 (1986)
Virella, J.C., Godoy, L.A., Suarez, L.E.: Fundamental models of tank-liquid systems under horizontal motions. Eng. Struct. 28(10), 1450–1461 (2006)
Acknowledgements
This research work was supported by the National Key R&D Program of China (2017YFC1500700).
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2023 The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Wu, J.Y., Yu, Q.Q., Gu, X.L. (2023). Experimental Study on Seismic Behavior of Liquid Storage Tanks Subjected to Vertical Earthquakes. In: Geng, G., Qian, X., Poh, L.H., Pang, S.D. (eds) Proceedings of The 17th East Asian-Pacific Conference on Structural Engineering and Construction, 2022. Lecture Notes in Civil Engineering, vol 302. Springer, Singapore. https://doi.org/10.1007/978-981-19-7331-4_16
Download citation
DOI: https://doi.org/10.1007/978-981-19-7331-4_16
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-19-7330-7
Online ISBN: 978-981-19-7331-4
eBook Packages: EngineeringEngineering (R0)