Abstract
Riverol-Pilipovik (RP) water treatment system is a reverse osmosis-based desalination plant which is represented by a set of transfer functions. At times, there may be variations in the parameters of the system which may change its behavior. In this paper, interval modeling of RP system is done to accommodate the effect of parametric variations. A comparative study of original system with its interval model is shown with the help of step response and impulse response. Also, the characteristics of the response are compared to demonstrate the resemblance of the interval model to the original system.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Rathore NS, Singh VP, Kumar B (2018) Controller design for doha water treatment plant using grey wolf optimization. J Intell Fuzzy Syst 35(5):5329–5336
Naresh P, Pattnaik S, Singh VP (2020) Salp swarm optimization based controller design for photovoltaic reverse osmosis plant. J Inf Optimiz Sci 41(2): 651–659
Chodavarapu MM, Singh VP, Devarapalli R (2020) Interval modeling of Riverol-Pilipovik water treatment plant and its model order reduction. In: Computing algorithms with applications in engineering, pp 361–367. Springer, Singapore
Choudhary AM, Nagar SK (2019) Order reduction in z-domain for interval system using an arithmetic operator. Circuits Syst Signal Process 38(3): 1023–1038
Bandyopadhyay B, Ismail O, Gorez R (1994) Routh-Pade approximation for interval systems. IEEE Trans Automatic Control 39:12:2454–2456
Bandyopadhyay B, Upadhye A, Ismail O /spl gamma/-/spl delta/Routh approximation for interval systems. IEEE Trans Automatic Control 42(8):1127–1130
Kumar DK, Nagar SK (2013) Direct truncation and factor division method for order reduction of interval systems. In: National conference on recent developments in control, automation and power engineering, pp 37–40
Kumar DK, Nagar SK, Tiwari JP (2011) Model order reduction of interval systems using mihailov criterion and factor division method. Int J Comput Appl 28(11):4–8
Kumar DK, Nagar SK, Tiwari JP (2013) Order reduction of interval systems using alpha and factor division method. In: Recent advancements in system modelling applications. Springer, India, pp 249–259
Riverol C, Pilipovik V (2005) Mathematical modeling of perfect decoupled control system and its application: a reverse osmosis desalination industrial-scale unit. J Autom Methods Manage Chem 2005(2):50–54
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2022 The Author(s), under exclusive license to Springer Nature Singapore Pte Ltd.
About this paper
Cite this paper
Mathur, N., Meena, V.P., Singh, V.P. (2022). Interval Modeling of Riverol-Pilipovik Water Treatment System. In: Gupta, A.R., Roy, N.K., Parida, S.K. (eds) Power Electronics and High Voltage in Smart Grid. Lecture Notes in Electrical Engineering, vol 817. Springer, Singapore. https://doi.org/10.1007/978-981-16-7393-1_13
Download citation
DOI: https://doi.org/10.1007/978-981-16-7393-1_13
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-16-7392-4
Online ISBN: 978-981-16-7393-1
eBook Packages: EnergyEnergy (R0)