Abstract
Coronary artery stenting has been an important therapeutic procedure for patients with coronary artery stenosis and the number of patients who received stenting is increasing. As a noninvasive method, coronary computed tomography angiography (CTA) has become increasingly used during the follow-up. However, beam-hardening artifacts, appearing as dark areas adjacent to metal stents, limit the diagnostic performance of cardiac CT, especially when the stent diameter is <3 mm. Recently, with the rapid technologic advances, dual-energy CT (DECT) has been applied in many clinical areas. With dual-energy CT, attenuation data from different energies are used to characterize materials, virtual monoenergetic images (VMI) and stent subtraction images can be used to improve the diagnostic performance of stent evaluation. In this chapter, based on a case, we will discuss the assessment of coronary stent by dual-energy CT imaging, and further possibly promising role of CT technology in coronary stent evaluation.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
McCollough CH, Leng S, Yu L, Fletcher JG. Dual- and multi-energy CT: principles, technical approaches, and clinical applications. Radiology. 2015;276(3):637–53. https://doi.org/10.1148/radiol.2015142631.
Secchi F, De Cecco CN, Spearman JV, Silverman JR, Ebersberger U, Sardanelli F, et al. Monoenergetic extrapolation of cardiac dual energy CT for artifact reduction. Acta Radiol. 2015;56(4):413–8. https://doi.org/10.1177/0284185114527867.
Yu L, Leng S, McCollough CH. Dual-energy CT-based monochromatic imaging. AJR Am J Roentgenol. 2012;199(5 Suppl):S9–s15. https://doi.org/10.2214/ajr.12.9121.
Hickethier T, Baessler B, Kroeger JR, Doerner J, Pahn G, Maintz D, et al. Monoenergetic reconstructions for imaging of coronary artery stents using spectral detector CT: in-vitro experience and comparison to conventional images. J Cardiovasc Comput Tomogr. 2017;11(1):33–9. https://doi.org/10.1016/j.jcct.2016.12.005.
Fuchs A, Kuhl JT, Chen MY, Helqvist S, Razeto M, Arakita K, et al. Feasibility of coronary calcium and stent image subtraction using 320-detector row CT angiography. J Cardiovasc Comput Tomogr. 2015;9(5):393–8. https://doi.org/10.1016/j.jcct.2015.03.016.
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2020 Springer Nature Singapore Pte Ltd.
About this chapter
Cite this chapter
Xu, C., Wang, Y. (2020). Dual-Energy Evaluation of Coronary Artery Stent. In: **, Zy., Lu, B., Wang, Y. (eds) Cardiac CT. Springer, Singapore. https://doi.org/10.1007/978-981-15-5305-9_5
Download citation
DOI: https://doi.org/10.1007/978-981-15-5305-9_5
Published:
Publisher Name: Springer, Singapore
Print ISBN: 978-981-15-5304-2
Online ISBN: 978-981-15-5305-9