Abstract
Magnetic Resonance Imaging (MRI) is a technique which provides high spatial resolution combined with a wide range of image contrast mechanisms. Standard MR image contrast relies upon tissue differences in MR visible hydrogen spin density, spin-lattice (T1) relaxation and spin-spin (T2) relaxation. In soft tissue, the variation of MR visible hydrogen spin density between tissues types is small (up to 30%) whereas T1 and T2 relaxation times can vary considerably (>100%). However, despite this sensitivity, these standard forms of contrast mainly reflect the longer term disruption of tissue structure. Since alterations in tissue function normally precede structural damage, MR image contrast which accurately reflects this tissue function holds the promise of earlier detection of pathophysiology.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Preview
Unable to display preview. Download preview PDF.
Similar content being viewed by others
References
Ordidge, R. J., Gorell, J.M., Deniau, J. C, Knight, R. A., and Helpern, J. A., 1994, Assessment of Relative Brain Iron Concentrations Using T2-Weigted and T2 *-Weighted MRI at 3 Tesla, Magn. Resort. Med., 32:335–341.
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G. Merkle, H., Ellermann, J. M., and Ugurbil, K., 1993, Functional brain map** by blood oxygenation level-dependent contrast magnetic resonance imaging, Biophys. J., 64:803–812.
Jezzard, P., Heineman, F., Taylor, J., DesPres, D., Wen, H., Balaban, R. S., and Turner, R., 1994, Comparison of EPI Gradient-Echo Contrast Changes in Cat Brain Caused By Respiratory Challenges with Direct Simultaneous Evaluation of Cerebral Oxygenation via a Cranial Window, NMR Biomed., 7:35–44.
Wyatt, J. S., Cope, M., Delpy, D. T., Edwards, A. D., Wray, S. C., and Reynolds, E. O. R., 1986, Quatification of cerebral oxygenation and hemodynamics in sick newborn infants by near infra red spectrophotometry, Lancet, II:1063–1066.
Matcher, S. J., Cope, M., Delpy, D.T., 1994, Use of water absorption spectrum to quantify tissue chromophore concentration changes in near infrared spectroscopy, Phys. Med. Biol., 39:177–196.
Matcher, S. J., and Cooper, C. E., 1994, Absolute quantification of deoxyhaemoglobin concentration in tissue near infrared spectroscopy. Phys. Med. Biol., 39:1295–1312.
Cooper, C. E., Elwell, C. E., Meek, H., Matcher, S. J., Wyatt, J. S., Cope, M., and Delpy, D. T., 1995, The non-invasive measurement of absolute cerebral deoxyhaemoglobin concentration and mean optical path-length in the neonatal brain by second derivative near infrared spectroscopy, Pediatr. Res., In press.
Lorek, A., Takei, Y., Cady, E. B., Wyatt, J. S., Penrice, J., Edwards, A. D., Peebles, D., Wylenzinska, M., Owen-Reece, H., Kirkbride, V, Cooper, C. E., Aldridge, R. F., Roth, S. C, Brown, G., Delpy, D. T., and Reynolds, E. O. R., 1994, Delayed („Secondary“) Cerebral Energy Failure after Acute Hypoxia-Ischaemia in the Newborn Piglet: Continuous 48-Hour Studies by Phosphorus Magnetic Resonance Spectroscopy, Pediatr. Res., 36(6).
Yablonskiy, D. A., and Haacke, E. M., 1994, Theory of NMR Signal Behavior in Magnetically Inhomogeneous Tissues: The Static Dephasing Regime, Magn. Reson. Med., 32:749–763.
Roth, S. C., Edwards, A. D., Cady, E.B., Delpy, D. T., Wyatt, J. S., Azzopardi, D., Baudin, J., Townsend, J., Stewart, A. L., and Reynolds, E. O., 1992, Relation between cerebral oxidative metabolism following birth aspyxia and neurodevelopmental outcome and brain growth at one year, Dev. Med. Child Neurol., 34:285–295.
Cope, M., Delpy, D. T., Wyatt, J. S., Wray, S. C, Reynolds, E. O. R., 1989, A CCD spectrometer to quantitate the concentration of chromophores in living tissue utilising the water absorption peak of water at 975 mm, Adv. Exp. Med. Biol., 247:33–31.
Essenpreis, M., Elwell, C. E., P. van der Zee, Arridge, S. R., and Delpy, D. T., 1993, Spectral dependance of temporal point spread functions in human tissues, Applied Optics, 32:418–425.
Schenk, J. F., 1992, Health and physiological effects of human exposure to whole body four tesla magnetic fields during MRI., Ann. N. Y. Acad. Sci., 649:285–301.
Hanjal, J. V., De coene, B., Lewis, P. D., Baudouin, C. J., Cowan, F. M., Pennrock, J. M., Young, I. R., Bydder, G., 1992, High signal regions in normal white matter shown by heavily T2-weighted CSF nulled IR sequences, J Comput. Assist. Tomogr., 16(4):506–513.
Matcher, S. J., Elwell, C. E., Cooper, C. E., Cope, M., and Delpy, D. T., 1995, Performance Comparison of Several Published Tissue Near-Infrared Spectroscopy Algorithms, Analyt. Biochem., 277, 54–68.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 1997 Springer Science+Business Media New York
About this chapter
Cite this chapter
Punwani, S. et al. (1997). Correlation between Absolute Deoxyhaemoglobin [dHb] Measured by Near Infrared Spectroscopy (NIRS) and Absolute R2′ as Determined by Magnetic Resonance Imaging (MRI). In: Villringer, A., Dirnagl, U. (eds) Optical Imaging of Brain Function and Metabolism 2. Advances in Experimental Medicine and Biology, vol 413. Springer, Boston, MA. https://doi.org/10.1007/978-1-4899-0056-2_14
Download citation
DOI: https://doi.org/10.1007/978-1-4899-0056-2_14
Publisher Name: Springer, Boston, MA
Print ISBN: 978-1-4899-0058-6
Online ISBN: 978-1-4899-0056-2
eBook Packages: Springer Book Archive