Part of the book series: Medical Radiology ((Med Radiol Radiat Oncol))

  • 2368 Accesses

Abstract

Elekta AB has developed a wide range of products and accessories to enable highly accurate and precise delivery for stereotactic body radiation therapy (SBRT). In this chapter the specific systems designed and manufactured by Elekta will be presented, including their developments for image guidance, multileaf collimation, specialized couchtops, and motion management strategies. Elekta has developed image guidance technology for kilovoltage cone beam CT, ultrasound, and 4D motion management tools. Elekta multileaf collimator (MLC) technology provides modulation for intensity modulated radiation therapy (IMRT) and has recently been improved to provide 4 mm leaves for high conformality SBRT. Elekta couchtops and treatment tables with 6D motion provide for improved patient setup, and a wide range of motion management solutions such as abdominal compression, active breathing coordination, and laser-based positioning systems. These technologies are combined in the latest line of linacs from Elekta, including the Synery-S and Axesse with their dedicated stereotactic radiotherapy (SRT) and SBRT features.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Subscribe and save

Springer+ Basic
EUR 32.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or Ebook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Chapter
EUR 29.95
Price includes VAT (Germany)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
EUR 181.89
Price includes VAT (Germany)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
EUR 234.33
Price includes VAT (Germany)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free ship** worldwide - see info
Hardcover Book
EUR 320.99
Price includes VAT (Germany)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free ship** worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Similar content being viewed by others

References

  • Ali I, Matthiesen C, Algan O, Thompson S, Bogardus C, Herman T, Ahmad S (2010) Quantitative evaluation of increase in surface dose by immobilization thermoplastic masks and superficial dosimetry using Gafchromic EBT film and Monte Carlo calculations. J Xray Sci Technol 18(3):319–326. doi:11406722QG780268 [pii], 10.3233/XST-2010-0263

    Google Scholar 

  • Amer A, Marchant T, Sykes J, Czajka J, Moore C (2007) Imaging doses from the Elekta Synergy X-ray cone beam CT system. Br J Radiol 80(954):476–482. doi:80/954/476[pii], 10.1259/bjr/80446730

    Google Scholar 

  • Benedict SH, Bova FJ, Clark B, Goetsch SJ, Hinson WH, Leavitt DD, Schlesinger DJ, Yenice KM (2008) Anniversary paper: the role of medical physicists in develo** stereotactic radiosurgery. Med Phys 35(9):4262–4277

    Article  PubMed  Google Scholar 

  • Benedict SH, Yenice KM, Followill D, Galvin JM, Hinson W, Kavanagh B, Keall P, Lovelock M, Meeks S, Papiez L, Purdie T, Sadagopan R, Schell MC, Salter B, Schlesinger DJ, Shiu AS, Solberg T, Song DY, Stieber V, Timmerman R, Tome WA, Verellen D, Wang L, Yin FF (2010) Stereotactic body radiation therapy: the report of AAPM task group 101. Med Phys 37(8):4078–4101

    Article  PubMed  Google Scholar 

  • Blomgren H, Lax I, Naslund I, Svanstrom R (1995) Stereotactic high dose fraction radiation therapy of extracranial tumors using an accelerator. Clinical experience of the first thirty-one patients. Acta Oncol 34(6):861–870

    Article  PubMed  CAS  Google Scholar 

  • Bradley JD, Nofal AN, El Naqa IM, Lu W, Liu J, Hubenschmidt J, Low DA, Drzymala RE, Khullar D (2006) Comparison of helical, maximum intensity projection (MIP), and averaged intensity (AI) 4D CT imaging for stereotactic body radiation therapy (SBRT) planning in lung cancer. Radiother Oncol 81(3):264–268

    Article  PubMed  Google Scholar 

  • Brock J, McNair HA, Panakis N, Symonds-Tayler R, Evans PM, Brada M (2011) The use of the active breathing coordinator throughout radical non-small-cell lung cancer (NSCLC) radiotherapy. Int J Radiat Oncol Biol Phys 81(2):369–375. doi:S0360-3016(10)00761-3[pii], 10.1016/j.ijrobp.2010.05.038

  • Brown K,Thompson G (2010) Agility: intelligent design. Elekta Whitepaper

    Google Scholar 

  • Cosgrove V, Thompson C, Christophides D, Wetson S, Thwaites D, Evans C, Thomas M, Warrington A, Reynaert N,Wagter CD (2009). Physical characterisation of a new concept design of an Elekta radiation head with integrated 160-leaf multi-leaf collimator. ASTRO 51st Annual Meeting

    Google Scholar 

  • Eccles C, Brock KK, Bissonnette JP, Hawkins M, Dawson LA (2006) Reproducibility of liver position using active breathing coordinator for liver cancer radiotherapy. Int J Radiat Oncol Biol Phys 64(3):751–759. doi:S0360-3016(05)02821-X[pii], 10.1016/j.ijrobp.2005.05.066

    Google Scholar 

  • Eccles CL, Dawson LA, Moseley JL,Brock KK (2011) Interfraction liver shape variability and impact on GTV position during liver stereotactic radiotherapy using abdominal compression. Int J Radiat Oncol Biol Phys 80(3):938–946

    Article  PubMed  Google Scholar 

  • Feigenberg SJ, Paskalev K, McNeeley S, Horwitz EM, Konski A, Wang L, Ma C, Pollack A (2007) Comparing computed tomography localization with daily ultrasound during image-guided radiation therapy for the treatment of prostate cancer: a prospective evaluation. J Appl Clin Med Phys 8(3):2268

    Article  PubMed  Google Scholar 

  • Fung AY, Enke CA, Ayyangar KM, Raman NV, Zhen W, Thompson RB, Li S, Nehru RM, Pillai S (2005) Prostate motion and isocenter adjustment from ultrasound-based localization during delivery of radiation therapy. Int J Radiat Oncol Biol Phys 61(4):984–992. doi:S0360-3016(04)02133-9[pii], 10.1016/j.ijrobp.2004.07.727

    Google Scholar 

  • Gong G, Yin Y, **ng L, Guo Y, Chen J, Liu T, Lu J, Ma C, Sun T, Bai T, Zhang G, Deng W (2011) Comparison of internal target volumes for hepatocellular carcinoma defined using 3DCT with active breathing coordinator and 4DCT. Technol Cancer Res Treat 10(6):601–606. c4318/Comparison-of-Internal-Target-Volumes-for-Hepatocellular-Carcinoma-Defined-Using-3DCT-with-Active-Breathing-Coordinator-and-4DCT-601-606-p17901.html [pii]

  • Gong GZ, Yin Y, **ng LG, Guo YJ, Liu T, Chen J, Lu J, Ma C, Sun T, Bai T, Zhang G, Wang R (2012) RapidArc combined with the active breathing coordinator provides an effective and accurate approach for the radiotherapy of hepatocellular carcinoma. Strahlenther Onkol 188(3):262–268. doi:10.1007/s00066-011-0044-5

    Article  PubMed  CAS  Google Scholar 

  • Heinzerling JH, Anderson JF, Papiez L, Boike T, Chien S, Zhang G, Abdulrahman R, Timmerman R (2008) Four-dimensional computed tomography scan analysis of tumor and organ motion at varying levels of abdominal compression during stereotactic treatment of lung and liver. Int J Radiat Oncol Biol Phys 70(5):1571–1578

    Article  PubMed  Google Scholar 

  • Jaffray DA, Siewerdsen JH, Wong JW, Martinez AA (2002) Flat-panel cone-beam computed tomography for image-guided radiation therapy. Int J Radiat Oncol Biol Phys 53(5):1337–1349

    Article  PubMed  Google Scholar 

  • Klein EE, Hanley J, Bayouth J, Yin FF, Simon W, Dresser S, Serago C, Aguirre F, Ma L, Arjomandy B, Liu C, Sandin C, Holmes T (2009) Task group 142 report: quality assurance of medical accelerators. Med Phys 36(9):4197–4212

    Article  PubMed  Google Scholar 

  • Lattanzi J, McNeeley S, Donnelly S, Palacio E, Hanlon A, Schultheiss TE, Hanks GE (2000) Ultrasound-based stereotactic guidance in prostate cancer—quantification of organ motion and set-up errors in external beam radiation therapy. Comput Aided Surg 5(4):289–295. doi:10.1002/1097-0150(2000)5:4<289::AID-IGS7>3.0.CO;2-D [pii], 10.1002/1097-0150(2000)5:4<289::AID-IGS7>3.0.CO;2-D

  • Lax I, Blomgren H, Naslund I, Svanstrom R (1994) Stereotactic radiotherapy of malignancies in the abdomen. Methodological aspects. Acta Oncol 33(6):677–683

    CAS  Google Scholar 

  • Lehmann J, Perks J, Semon S, Harse R, Purdy JA (2007) Commissioning experience with cone-beam computed tomography for image-guided radiation therapy. J Appl Clin Med Phys 8(3):2354

    Article  PubMed  Google Scholar 

  • Leksell L (1951) The stereotaxic method and radiosurgery of the brain. Acta Chir Scand 102(4):316–319

    PubMed  CAS  Google Scholar 

  • Letourneau D, Wong JW, Oldham M, Gulam M, Watt L, Jaffray DA, Siewerdsen JH, Martinez AA (2005) Cone-beam-CT guided radiation therapy: technical implementation. Radiother Oncol 75(3):279–286

    Article  PubMed  Google Scholar 

  • Li XA, Keall PJ, Orton CG (2007) Point/counterpoint. Respiratory gating for radiation therapy is not ready for prime time. Med Phys 34(3):867–870

    Article  PubMed  Google Scholar 

  • Linthout N, Verellen D, Van Acker S, Van de Vondel I, Coppens L, Storme G (2002) Assessment of the acceptability of the Elekta multileaf collimator (MLC) within the Corvus planning system for static and dynamic delivery of intensity modulated beams (IMBs). Radiother Oncol 63(1):121–124. doi:S0167814002000312 [pii]

    Google Scholar 

  • Lutz W, Winston KR, Maleki N (1988) A system for stereotactic radiosurgery with a linear accelerator. Int J Radiat Oncol Biol Phys 14(2):373–381

    Article  PubMed  CAS  Google Scholar 

  • McGarry RC, Papiez L, Williams M, Whitford T, Timmerman RD (2005) Stereotactic body radiation therapy of early-stage non-small-cell lung carcinoma: phase I study. Int J Radiat Oncol Biol Phys 63(4):1010–1015. doi:S0360-3016(05)00832-1[pii], 10.1016/j.ijrobp.2005.03.073

    Google Scholar 

  • Meyer J, Wilbert J, Baier K, Guckenberger M, Richter A, Sauer O, Flentje M (2007) Positioning accuracy of cone-beam computed tomography in combination with a HexaPOD robot treatment table. Int J Radiat Oncol Biol Phys 67(4):1220–1228. doi:S0360-3016(06)03373-6[pii], 10.1016/j.ijrobp.2006.11.010

    Google Scholar 

  • Nakagawa K, Aoki Y, Tago M, Terahara A, Ohtomo K (2000) Megavoltage CT-assisted stereotactic radiosurgery for thoracic tumors: original research in the treatment of thoracic neoplasms. Int J Radiat Oncol Biol Phys 48(2):449–457. doi:S0360-3016(00)00617-9 [pii]

    Google Scholar 

  • Oldham M, Letourneau D, Watt L, Hugo G, Yan D, Lockman D, Kim LH, Chen PY, Martinez A, Wong JW (2005) Cone-beam-CT guided radiation therapy: a model for on-line application. Radiother Oncol 75(3):271–278

    Article  PubMed  Google Scholar 

  • Patel I, Glendinning AG, Kirby MC (2005) Dosimetric characteristics of the Elekta beam modulator. Phys Med Biol 50(23):5479–5492. doi:S0031-9155(05)02725-9[pii], 10.1088/0031-9155/50/23/004

    Google Scholar 

  • Perks J, Lehmann J, Narayan S, Semon S, Stern S, Vijayakumar S, Purdy J (2010) Utilization of image-guided radiation therapy equipment to enhance stereotactic body radiation therapy commissioning. Radiosurgery 7:397–402. McDermott, Karger

    Google Scholar 

  • Pouliot J, Bani-Hashemi A, Chen J, Svatos M, Ghelmansarai F, Mitschke M, Aubin M, **a P, Morin O, Bucci K, Roach M 3rd, Hernandez P, Zheng Z, Hristov D, Verhey L (2005) Low-dose megavoltage cone-beam CT for radiation therapy. Int J Radiat Oncol Biol Phys 61(2):552–560

    Article  PubMed  Google Scholar 

  • Riis HL, Zimmermann SJ (2009) Elekta precise table characteristics of IGRT remote table positioning. Acta Oncol 48(2):267–270. doi:902010344[pii], 10.1080/02841860802311007

    Google Scholar 

  • Riis HL, Zimmermann SJ, Riis P (2010) Isocentric rotational performance of the Elekta precise table studied using a USB-microscope. Phys Med Biol 55(24):7597–7614. doi:S0031-9155(10)58127-2[pii], 10.1088/0031-9155/55/24/014

    Google Scholar 

  • Rit S, Wolthaus J, van Herk M, Sonke JJ (2008) On-the-fly motion-compensated cone-beam CT using an a priori motion model. Med Image Comput Comput Assist Interv 11(Pt 1):729–736

    PubMed  Google Scholar 

  • Rit S, Wolthaus JW, van Herk M, Sonke JJ (2009) On-the-fly motion-compensated cone-beam CT using an a priori model of the respiratory motion. Med Phys 36(6):2283–2296

    Article  PubMed  Google Scholar 

  • Sayer FT, Sherman JH, Yen CP, Schlesinger DJ, Kersh R, Sheehan JP (2011) Initial experience with the eXtend system: a relocatable frame system for multiple-session gamma knife radiosurgery. World Neurosurg 75(5–6):665–672. doi:S1878-8750(11)00025-8[pii], 10.1016/j.wneu.2010.12.051

  • Schmidhalter D, Fix MK, Niederer P, Mini R, Manser P (2007) Leaf transmission reduction using moving jaws for dynamic MLC IMRT. Med Phys 34(9):3674–3687

    Article  PubMed  CAS  Google Scholar 

  • Sonke JJ, Rossi M, Wolthaus J, van Herk M, Damen E, Belderbos J (2009) Frameless stereotactic body radiotherapy for lung cancer using four-dimensional cone beam CT guidance. Int J Radiat Oncol Biol Phys 74(2):567–574

    Article  PubMed  Google Scholar 

  • Timmerman R, Papiez L, McGarry R, Likes L, DesRosiers C, Frost S, Williams M (2003) Extracranial stereotactic radioablation: results of a phase I study in medically inoperable stage I non-small cell lung cancer. Chest 124(5):1946–1955

    Article  PubMed  Google Scholar 

  • Van de Walle J, Martens C, Reynaert N, Palmans H, Coghe M, De Neve W, De Wagter C, Thierens H (2003) Monte Carlo model of the Elekta SLiplus accelerator: validation of a new MLC component module in BEAM for a 6 MV beam. Phys Med Biol 48(3):371–385

    Article  PubMed  Google Scholar 

  • Winston KR, Lutz W (1988) Linear accelerator as a neurosurgical tool for stereotactic radiosurgery. Neurosurgery 22(3):454–464

    Article  PubMed  CAS  Google Scholar 

  • Wolthaus JW, Sonke JJ, van Herk M, Belderbos JS, Rossi MM, Lebesque JV, Damen EM (2008) Comparison of different strategies to use four-dimensional computed tomography in treatment planning for lung cancer patients. Int J Radiat Oncol Biol Phys 70(4):1229–1238. doi:S0360-3016(07)04592-0[pii], 10.1016/j.ijrobp.2007.11.042

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Stanley H. Benedict .

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2012 Springer-Verlag Berlin Heidelberg

About this chapter

Cite this chapter

Perks, J.R., Daly, M.E., Schlesinger, D., Benedict, S.H. (2012). Elekta System. In: Lo, S., Teh, B., Lu, J., Schefter, T. (eds) Stereotactic Body Radiation Therapy. Medical Radiology(). Springer, Berlin, Heidelberg. https://doi.org/10.1007/174_2012_643

Download citation

  • DOI: https://doi.org/10.1007/174_2012_643

  • Publisher Name: Springer, Berlin, Heidelberg

  • Print ISBN: 978-3-642-25604-2

  • Online ISBN: 978-3-642-25605-9

  • eBook Packages: MedicineMedicine (R0)

Publish with us

Policies and ethics

Navigation