Abstract
Elekta AB has developed a wide range of products and accessories to enable highly accurate and precise delivery for stereotactic body radiation therapy (SBRT). In this chapter the specific systems designed and manufactured by Elekta will be presented, including their developments for image guidance, multileaf collimation, specialized couchtops, and motion management strategies. Elekta has developed image guidance technology for kilovoltage cone beam CT, ultrasound, and 4D motion management tools. Elekta multileaf collimator (MLC) technology provides modulation for intensity modulated radiation therapy (IMRT) and has recently been improved to provide 4 mm leaves for high conformality SBRT. Elekta couchtops and treatment tables with 6D motion provide for improved patient setup, and a wide range of motion management solutions such as abdominal compression, active breathing coordination, and laser-based positioning systems. These technologies are combined in the latest line of linacs from Elekta, including the Synery-S and Axesse with their dedicated stereotactic radiotherapy (SRT) and SBRT features.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Ali I, Matthiesen C, Algan O, Thompson S, Bogardus C, Herman T, Ahmad S (2010) Quantitative evaluation of increase in surface dose by immobilization thermoplastic masks and superficial dosimetry using Gafchromic EBT film and Monte Carlo calculations. J Xray Sci Technol 18(3):319–326. doi:11406722QG780268 [pii], 10.3233/XST-2010-0263
Amer A, Marchant T, Sykes J, Czajka J, Moore C (2007) Imaging doses from the Elekta Synergy X-ray cone beam CT system. Br J Radiol 80(954):476–482. doi:80/954/476[pii], 10.1259/bjr/80446730
Benedict SH, Bova FJ, Clark B, Goetsch SJ, Hinson WH, Leavitt DD, Schlesinger DJ, Yenice KM (2008) Anniversary paper: the role of medical physicists in develo** stereotactic radiosurgery. Med Phys 35(9):4262–4277
Benedict SH, Yenice KM, Followill D, Galvin JM, Hinson W, Kavanagh B, Keall P, Lovelock M, Meeks S, Papiez L, Purdie T, Sadagopan R, Schell MC, Salter B, Schlesinger DJ, Shiu AS, Solberg T, Song DY, Stieber V, Timmerman R, Tome WA, Verellen D, Wang L, Yin FF (2010) Stereotactic body radiation therapy: the report of AAPM task group 101. Med Phys 37(8):4078–4101
Blomgren H, Lax I, Naslund I, Svanstrom R (1995) Stereotactic high dose fraction radiation therapy of extracranial tumors using an accelerator. Clinical experience of the first thirty-one patients. Acta Oncol 34(6):861–870
Bradley JD, Nofal AN, El Naqa IM, Lu W, Liu J, Hubenschmidt J, Low DA, Drzymala RE, Khullar D (2006) Comparison of helical, maximum intensity projection (MIP), and averaged intensity (AI) 4D CT imaging for stereotactic body radiation therapy (SBRT) planning in lung cancer. Radiother Oncol 81(3):264–268
Brock J, McNair HA, Panakis N, Symonds-Tayler R, Evans PM, Brada M (2011) The use of the active breathing coordinator throughout radical non-small-cell lung cancer (NSCLC) radiotherapy. Int J Radiat Oncol Biol Phys 81(2):369–375. doi:S0360-3016(10)00761-3[pii], 10.1016/j.ijrobp.2010.05.038
Brown K,Thompson G (2010) Agility: intelligent design. Elekta Whitepaper
Cosgrove V, Thompson C, Christophides D, Wetson S, Thwaites D, Evans C, Thomas M, Warrington A, Reynaert N,Wagter CD (2009). Physical characterisation of a new concept design of an Elekta radiation head with integrated 160-leaf multi-leaf collimator. ASTRO 51st Annual Meeting
Eccles C, Brock KK, Bissonnette JP, Hawkins M, Dawson LA (2006) Reproducibility of liver position using active breathing coordinator for liver cancer radiotherapy. Int J Radiat Oncol Biol Phys 64(3):751–759. doi:S0360-3016(05)02821-X[pii], 10.1016/j.ijrobp.2005.05.066
Eccles CL, Dawson LA, Moseley JL,Brock KK (2011) Interfraction liver shape variability and impact on GTV position during liver stereotactic radiotherapy using abdominal compression. Int J Radiat Oncol Biol Phys 80(3):938–946
Feigenberg SJ, Paskalev K, McNeeley S, Horwitz EM, Konski A, Wang L, Ma C, Pollack A (2007) Comparing computed tomography localization with daily ultrasound during image-guided radiation therapy for the treatment of prostate cancer: a prospective evaluation. J Appl Clin Med Phys 8(3):2268
Fung AY, Enke CA, Ayyangar KM, Raman NV, Zhen W, Thompson RB, Li S, Nehru RM, Pillai S (2005) Prostate motion and isocenter adjustment from ultrasound-based localization during delivery of radiation therapy. Int J Radiat Oncol Biol Phys 61(4):984–992. doi:S0360-3016(04)02133-9[pii], 10.1016/j.ijrobp.2004.07.727
Gong G, Yin Y, **ng L, Guo Y, Chen J, Liu T, Lu J, Ma C, Sun T, Bai T, Zhang G, Deng W (2011) Comparison of internal target volumes for hepatocellular carcinoma defined using 3DCT with active breathing coordinator and 4DCT. Technol Cancer Res Treat 10(6):601–606. c4318/Comparison-of-Internal-Target-Volumes-for-Hepatocellular-Carcinoma-Defined-Using-3DCT-with-Active-Breathing-Coordinator-and-4DCT-601-606-p17901.html [pii]
Gong GZ, Yin Y, **ng LG, Guo YJ, Liu T, Chen J, Lu J, Ma C, Sun T, Bai T, Zhang G, Wang R (2012) RapidArc combined with the active breathing coordinator provides an effective and accurate approach for the radiotherapy of hepatocellular carcinoma. Strahlenther Onkol 188(3):262–268. doi:10.1007/s00066-011-0044-5
Heinzerling JH, Anderson JF, Papiez L, Boike T, Chien S, Zhang G, Abdulrahman R, Timmerman R (2008) Four-dimensional computed tomography scan analysis of tumor and organ motion at varying levels of abdominal compression during stereotactic treatment of lung and liver. Int J Radiat Oncol Biol Phys 70(5):1571–1578
Jaffray DA, Siewerdsen JH, Wong JW, Martinez AA (2002) Flat-panel cone-beam computed tomography for image-guided radiation therapy. Int J Radiat Oncol Biol Phys 53(5):1337–1349
Klein EE, Hanley J, Bayouth J, Yin FF, Simon W, Dresser S, Serago C, Aguirre F, Ma L, Arjomandy B, Liu C, Sandin C, Holmes T (2009) Task group 142 report: quality assurance of medical accelerators. Med Phys 36(9):4197–4212
Lattanzi J, McNeeley S, Donnelly S, Palacio E, Hanlon A, Schultheiss TE, Hanks GE (2000) Ultrasound-based stereotactic guidance in prostate cancer—quantification of organ motion and set-up errors in external beam radiation therapy. Comput Aided Surg 5(4):289–295. doi:10.1002/1097-0150(2000)5:4<289::AID-IGS7>3.0.CO;2-D [pii], 10.1002/1097-0150(2000)5:4<289::AID-IGS7>3.0.CO;2-D
Lax I, Blomgren H, Naslund I, Svanstrom R (1994) Stereotactic radiotherapy of malignancies in the abdomen. Methodological aspects. Acta Oncol 33(6):677–683
Lehmann J, Perks J, Semon S, Harse R, Purdy JA (2007) Commissioning experience with cone-beam computed tomography for image-guided radiation therapy. J Appl Clin Med Phys 8(3):2354
Leksell L (1951) The stereotaxic method and radiosurgery of the brain. Acta Chir Scand 102(4):316–319
Letourneau D, Wong JW, Oldham M, Gulam M, Watt L, Jaffray DA, Siewerdsen JH, Martinez AA (2005) Cone-beam-CT guided radiation therapy: technical implementation. Radiother Oncol 75(3):279–286
Li XA, Keall PJ, Orton CG (2007) Point/counterpoint. Respiratory gating for radiation therapy is not ready for prime time. Med Phys 34(3):867–870
Linthout N, Verellen D, Van Acker S, Van de Vondel I, Coppens L, Storme G (2002) Assessment of the acceptability of the Elekta multileaf collimator (MLC) within the Corvus planning system for static and dynamic delivery of intensity modulated beams (IMBs). Radiother Oncol 63(1):121–124. doi:S0167814002000312 [pii]
Lutz W, Winston KR, Maleki N (1988) A system for stereotactic radiosurgery with a linear accelerator. Int J Radiat Oncol Biol Phys 14(2):373–381
McGarry RC, Papiez L, Williams M, Whitford T, Timmerman RD (2005) Stereotactic body radiation therapy of early-stage non-small-cell lung carcinoma: phase I study. Int J Radiat Oncol Biol Phys 63(4):1010–1015. doi:S0360-3016(05)00832-1[pii], 10.1016/j.ijrobp.2005.03.073
Meyer J, Wilbert J, Baier K, Guckenberger M, Richter A, Sauer O, Flentje M (2007) Positioning accuracy of cone-beam computed tomography in combination with a HexaPOD robot treatment table. Int J Radiat Oncol Biol Phys 67(4):1220–1228. doi:S0360-3016(06)03373-6[pii], 10.1016/j.ijrobp.2006.11.010
Nakagawa K, Aoki Y, Tago M, Terahara A, Ohtomo K (2000) Megavoltage CT-assisted stereotactic radiosurgery for thoracic tumors: original research in the treatment of thoracic neoplasms. Int J Radiat Oncol Biol Phys 48(2):449–457. doi:S0360-3016(00)00617-9 [pii]
Oldham M, Letourneau D, Watt L, Hugo G, Yan D, Lockman D, Kim LH, Chen PY, Martinez A, Wong JW (2005) Cone-beam-CT guided radiation therapy: a model for on-line application. Radiother Oncol 75(3):271–278
Patel I, Glendinning AG, Kirby MC (2005) Dosimetric characteristics of the Elekta beam modulator. Phys Med Biol 50(23):5479–5492. doi:S0031-9155(05)02725-9[pii], 10.1088/0031-9155/50/23/004
Perks J, Lehmann J, Narayan S, Semon S, Stern S, Vijayakumar S, Purdy J (2010) Utilization of image-guided radiation therapy equipment to enhance stereotactic body radiation therapy commissioning. Radiosurgery 7:397–402. McDermott, Karger
Pouliot J, Bani-Hashemi A, Chen J, Svatos M, Ghelmansarai F, Mitschke M, Aubin M, **a P, Morin O, Bucci K, Roach M 3rd, Hernandez P, Zheng Z, Hristov D, Verhey L (2005) Low-dose megavoltage cone-beam CT for radiation therapy. Int J Radiat Oncol Biol Phys 61(2):552–560
Riis HL, Zimmermann SJ (2009) Elekta precise table characteristics of IGRT remote table positioning. Acta Oncol 48(2):267–270. doi:902010344[pii], 10.1080/02841860802311007
Riis HL, Zimmermann SJ, Riis P (2010) Isocentric rotational performance of the Elekta precise table studied using a USB-microscope. Phys Med Biol 55(24):7597–7614. doi:S0031-9155(10)58127-2[pii], 10.1088/0031-9155/55/24/014
Rit S, Wolthaus J, van Herk M, Sonke JJ (2008) On-the-fly motion-compensated cone-beam CT using an a priori motion model. Med Image Comput Comput Assist Interv 11(Pt 1):729–736
Rit S, Wolthaus JW, van Herk M, Sonke JJ (2009) On-the-fly motion-compensated cone-beam CT using an a priori model of the respiratory motion. Med Phys 36(6):2283–2296
Sayer FT, Sherman JH, Yen CP, Schlesinger DJ, Kersh R, Sheehan JP (2011) Initial experience with the eXtend system: a relocatable frame system for multiple-session gamma knife radiosurgery. World Neurosurg 75(5–6):665–672. doi:S1878-8750(11)00025-8[pii], 10.1016/j.wneu.2010.12.051
Schmidhalter D, Fix MK, Niederer P, Mini R, Manser P (2007) Leaf transmission reduction using moving jaws for dynamic MLC IMRT. Med Phys 34(9):3674–3687
Sonke JJ, Rossi M, Wolthaus J, van Herk M, Damen E, Belderbos J (2009) Frameless stereotactic body radiotherapy for lung cancer using four-dimensional cone beam CT guidance. Int J Radiat Oncol Biol Phys 74(2):567–574
Timmerman R, Papiez L, McGarry R, Likes L, DesRosiers C, Frost S, Williams M (2003) Extracranial stereotactic radioablation: results of a phase I study in medically inoperable stage I non-small cell lung cancer. Chest 124(5):1946–1955
Van de Walle J, Martens C, Reynaert N, Palmans H, Coghe M, De Neve W, De Wagter C, Thierens H (2003) Monte Carlo model of the Elekta SLiplus accelerator: validation of a new MLC component module in BEAM for a 6 MV beam. Phys Med Biol 48(3):371–385
Winston KR, Lutz W (1988) Linear accelerator as a neurosurgical tool for stereotactic radiosurgery. Neurosurgery 22(3):454–464
Wolthaus JW, Sonke JJ, van Herk M, Belderbos JS, Rossi MM, Lebesque JV, Damen EM (2008) Comparison of different strategies to use four-dimensional computed tomography in treatment planning for lung cancer patients. Int J Radiat Oncol Biol Phys 70(4):1229–1238. doi:S0360-3016(07)04592-0[pii], 10.1016/j.ijrobp.2007.11.042
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2012 Springer-Verlag Berlin Heidelberg
About this chapter
Cite this chapter
Perks, J.R., Daly, M.E., Schlesinger, D., Benedict, S.H. (2012). Elekta System. In: Lo, S., Teh, B., Lu, J., Schefter, T. (eds) Stereotactic Body Radiation Therapy. Medical Radiology(). Springer, Berlin, Heidelberg. https://doi.org/10.1007/174_2012_643
Download citation
DOI: https://doi.org/10.1007/174_2012_643
Publisher Name: Springer, Berlin, Heidelberg
Print ISBN: 978-3-642-25604-2
Online ISBN: 978-3-642-25605-9
eBook Packages: MedicineMedicine (R0)