Elimination of Matrix Effect and Simultaneous Determination of Multi-components in Complex Systems by Matrix Coefficient Non-linearity Multivariate Calibration Based on Single Point Response Signals

  • Published:
Analytical Sciences Aims and scope Submit manuscript

Abstract

In order to deal with the matrix effect in the simultaneous determination of multi-components in a complex system, we have developed a novel method named matrix coefficient multivariate calibration method (MCMCM) for simultaneously determining n analytes in complex systems. The calibration models of n analytes, which are based on the experimental data of known samples, are first transformed into n linear equations, and then the equations are solved to obtain matrix calibration coefficients of the analytes in congeneric samples. In this way, the concentrations of n analytes in the unknown sample could be obtained easily and simultaneously by solving another n-variate linear equations with the help of the matrix calibration coefficients obtained-above. The method proposed in this work has been tested by voltammetry and atomic absorption spectrometry (AAS) with satisfactory results. On determining the elements such as Cu, Pb, Cd, Ni, Zn, Fe, Mn, Co, Ca, Mg, etc. in synthetic samples, the relative standard deviations (RSDs) of the results were 0.91–4.5%, and the recoveries were 95.8–105%. For actual samples, the RSDs and the recoveries were 1.5–6.9 and 92.0–110%, respectively.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
EUR 32.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or Ebook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price includes VAT (Germany)

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. C.-J. Xu, Y.-Z. Liang, and F.-T. Chau, Talanta, 2005 68(1), 108.

    Article  CAS  Google Scholar 

  2. F.-Q. Guo, L.-F. Huang, S.-Y. Zhou, T.-M. Zhang, and Y.-Z. Liang, Anal. Chim. Acta, 2006, 570(1), 73.

    Article  CAS  Google Scholar 

  3. C.-X. Zhao, X.-N. Li, Y.-Z. Liang, H.-Z. Fang, L.-F. Huang, and F.-Q. Guo, Chemom. Intell. Lab. Syst., 2006 82(1–1), 218.

    Article  CAS  Google Scholar 

  4. F.-Q. Guo, L. Ai, L.-F. Huang, Y.-Z. Liang, and B.-M. Chen, Pharm. Biomed. Anal., 2006, 40(3), 623.

    Article  CAS  Google Scholar 

  5. F.-Q. Guo, Y.-Z. Liang, and C.-J. Xu, Chromatogr., A 2004, 1054(1–1), 73.

    Article  CAS  Google Scholar 

  6. M.-H. Zhang and Y.-Z. Liang, J. Trace Microprobe Tech. 2002, 20(1), 1.

    Article  CAS  Google Scholar 

  7. P. L. Buldini, S. Cavalli, and J. L. Sharma, Microchem. J. 2002, 72, 277.

    Article  CAS  Google Scholar 

  8. C. C. Nascentes, M. Y. Kamogawa, K. G. Fernandes, M. A. Z. Arruda, A. R. A. Nogueira, and J. A. Nóbrega Spectrochim. Acta, Part B, 2005, 60(5), 749.

    Article  Google Scholar 

  9. E. Marguí, M. Hidalgo, and I. Queralt, Spectrochim. Acta Part B, 2005, 60(9–9), 1363.

    Article  Google Scholar 

  10. S. Chen, Y.-Z. Xu, Y.-H. Bi, W. Du, and B.-F. Liu Talanta, 2006, 70(1), 63.

    Article  CAS  Google Scholar 

  11. B. E. H. Saxbery and B. R. Kowaski, Anal. Chem., 1979 51, 1038.

    Google Scholar 

  12. P. Niedzielski, Anal. Chim. Acta, 2005, 551(1–2), 199.

    Article  CAS  Google Scholar 

  13. A. Aslan, G. Budak, E. Tirasoglu, and A. Karabulut, J. Quant. Spectrosc. Radiat. Trans., 2006, 97(1), 10.

    Article  CAS  Google Scholar 

  14. F. Garay and V. M. Solis, J. Electroanal. Chem., 2003 544, 1.

    Article  CAS  Google Scholar 

  15. T.-M. Zhang, J. Cao, and Y.-Z. Liang, Chem. Chin. Univ. 2006, 27(1), 37.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yi-Zeng Liang.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Zhang, TM., Yuan, B., Liang, YZ. et al. Elimination of Matrix Effect and Simultaneous Determination of Multi-components in Complex Systems by Matrix Coefficient Non-linearity Multivariate Calibration Based on Single Point Response Signals. ANAL. SCI. 23, 581–587 (2007). https://doi.org/10.2116/analsci.23.581

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.2116/analsci.23.581

Navigation