Abstract
Using a 120 kV STEM equipped with a backscattered electron detector and operated as a conventional SEM. voids in metal lines can be detected through 1 μm of passivation. By applying current to passivated thin metal lines while in the microscope, voids can be observed while electromigration is in progress. Voids move significant distances during electromigration. On at least some occasions. failure of the line is not the result of a void growing until the width of the line is reached. On these occasions, when the size of the void approaches the width of the line. the void breaks up into smaller voids.
Similar content being viewed by others
References
N. G. Ainslie, F. M. d'Heurle, and O. C. Wells. Appl. Phys. Lett.20. 173 (1972).
E. Castaño, J. Maiz, P. Flinn, and M. Madden, Appl. Phys. Lett.59, 129 (1991).
P. Besser, M. Madden, P. Flinn, submitted to J. Appl. Phys.
E. Levine and J. Kitcher, Proceedings of the 22nd Annual IEEE International Reliability Physics Symposium, USA (1984). p. 242.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Madden, M.C., Abratowski, E.V., Marieb, T. et al. High Resolution Observation of Void Motion in Passivated Metal Lines Under Electromigration Stress. MRS Online Proceedings Library 265, 33–38 (1992). https://doi.org/10.1557/PROC-265-33
Published:
Issue Date:
DOI: https://doi.org/10.1557/PROC-265-33