Introduction

The systolic workload imposed on the heart is substantially impaired by increased arterial stiffness and excessive pressure pulsatility, which have emerged as significant predictors of cardiovascular risk in diseased populations1,2. Progressive arterial stiffening, together with changes in aortic geometry, local arterial branching, and lumen narrowing, creates a mismatch in vascular impedance3,4. This impedance mismatch causes partial reflections of the forward pressure wave (i.e., a reflected wave traveling back to the central aorta), impairing the systolic loading condition for the left ventricle coupled to the arterial system5,6. Thus, vascular reflections caused by arterial stiffening affect the pressure wave shape in the proximal aorta7, and the severity of their effects depends on the magnitude and time of return from the peripheral circulation.

A complete description of arterial wave properties, including wave transit time (τw) and wave reflection magnitude (RM) or wave reflection index (RI), requires simultaneous records of aortic pressure and flow signals. In clinical practice, it is helpful to measure arterial wave properties by using minimally invasive physiological signals if possible. Analysis of the aortic pressure waveform is a method frequently used to assess large artery properties and arterial stiffness. In 2006, Westerhof et al.8 provided a novel method for calculating pressure wave reflection on the basis of the measured aortic pressure alone. Using an unknown aortic flow with a triangular shape, they successfully separated the measured pressure pulse into its forward and backward components to calculate the RM and RI. However, the return time of the reflected wave from peripheral circulation was not quantified in their study.

The return time of the reflected wave is the time difference between the forward and backward pressure waves. In 2008, Qasem and Avolio9 estimated pulse transit time from waveform decomposition of central aortic pressure by using a cross-correlation of modified forward and backward waves. Another method for determining wave transmission time entails using the vascular impulse response function in the arterial system. In 1980, Sipkema et al.10 revealed the presence of clear peaks in impulse response, and the measurement of the time intervals between these peaks enabled them to calculate the return time of the reflected wave traveling back to the ascending aorta.

In this study, we evaluated a method for determining τw from the impulse response of the filtered aortic input impedance (Zi) on the basis of the measurement of a single aortic pressure pulse and an assumed triangular flow wave (Qtri). The base of the unknown Qtri was constructed with a duration set equal to ejection time. The timing of the peak triangle, which was close to the peak of the measured aortic flow (Qm), was derived from the fourth-order derivative of the pressure waveform. RM and RI were calculated from the forward and backward components of the pressure pulse by using wave separation analysis. Healthy rats (NC), rats with chronic kidney disease (CKD), and rats with type 1 or type 2 diabetes mellitus (DM) were analyzed. The values of τw and RM and RI obtained using Qtri were compared with those obtained from Qm.

Results

Measurements were performed in the NC, CKD, and type 1 and type 2 DM groups. Their baseline characteristics are displayed in Table 1. The CKD rats exhibited impaired renal function, as manifested by increased serum creatinine (SCr) and blood urea nitrogen (BUN). The hemodynamic condition in the rats with CKD was characterized by (1) no alteration in basal heart rate (HR) and cardiac output (CO) and (2) an augmentation in systolic (Ps), diastolic (Pd), and mean (Pm) pressures in the aorta. The notable increase in Pm was the dominant factor responsible for the increase of 52.7% in total peripheral resistance (Rp) in the CKD rats compared with the NC. The rats with streptozotocin (STZ)-induced type 1 DM had higher blood glucose levels associated with a decrease in body weight (BW). Table 1 also illustrates that, partially protected by nicotinamide (NA), the STZ-NA-induced type 2 DM elicited moderate and stable hyperglycemia and prevented STZ-induced hypoinsulinemia and BW loss. Both diabetic groups showed significant declines in HR, but not in aortic pressure profiles. With unchanged Pm, the decreased CO was the predominant factor responsible for an increase in Rp in the rats with type 2 DM.

Table 1 Baseline characteristics in healthy rats, rats with chronic kidney disease, and rats with either type 1 or type 2 diabetes.

Figure 1 exemplifies the construction of an uncalibrated triangular flow from the measured pressure waveform in a healthy rat. The base of the triangle is constructed with a duration set equal to ejection time. The start and end time points of ejection are identified as the intersection of two tangential lines around the foot of the pressure wave (first vertical blue line) and that around the incisura (third vertical blue line), respectively. After ejection commenced, the peak of the triangle is set at the first zero crossing (from above to below) on the fourth-order derivative of the aortic pressure wave (second vertical blue line). Thus, the uncalibrated flow is approximated by a triangle, which is represented by the green line.

Figure 1: Construction of an uncalibrated triangular flow from the measured pressure waveform in a healthy rat.
figure 1

The start and end time points of the base of the triangle are identified as the intersection of two tangential lines around the foot of the pressure wave (first vertical blue line) and that around the incisura (third vertical blue line), respectively. After ejection commenced, the peak of the triangle is set at the first zero crossing (from above to below) on the fourth-order derivative of the aortic pressure wave (second vertical blue line). Thus, the uncalibrated flow is approximated by a triangle, which is represented by the green line. P, measured aortic pressure; Qm, measured aortic flow; Qtri, uncalibrated triangular flow.

Figure 2 shows the similarity between the measured aortic impulse response obtained from the measured pressure and Qm (A) and the predicted aortic impulse response obtained from the measured pressure and Qtri (B). In A and B, the dashed green line indicates that the aortic characteristic impedance (Zc) component of the vascular impulse response has been removed. One-half of the time difference between the appearance of the reflected peak (long arrow) and the initial peak (short arrow) approximates arterial τw in the lower body circulation. The similarities between the measured forward and backward pressure waves (C) and the predicted forward and backward pressure waves (D) are also presented. In C and D, the amplitudes (peak–trough) of the backward and forward pressure waves are represented by |Pb| and |Pf|, respectively.

Figure 2
figure 2

Similarity between the measured aortic impulse response obtained from the measured pressure and Qm (A) and the predicted aortic impulse response obtained from the measured pressure and Qtri (B). In (A and B), the green line indicates that the Zc component of the vascular impulse response has been removed. One-half of the time difference between the appearance of the reflected peak (long arrow) and the initial peak (short arrow) approximates τw in the lower body circulation. The similarities between the measured forward and backward pressure waves (C) and the predicted forward and backward pressure waves (D) are also presented. In (C and D), the amplitudes (peak–trough) of the backward and forward pressure waves are represented by |Pb| and |Pf|, respectively. Qm, measured aortic flow; Qtri, uncalibrated triangular flow; Zc, aortic characteristic impedance; τw, wave transit time.

Figure 3 displays relations between RM, RI, and τw calculated from the measured pressure and Qm (RMmQ, RImQ, and τwmQ; on the horizontal axes) and RM, RI, and τw calculated from the measured pressure and Qtri (RMtriQ, RItriQ, and τwtriQ; on the vertical axes). Figure 3A shows a significant regression line for RM: RMtriQ = −0.0095 + 0.9652 × RMmQ (r2 = 0.8301; P < 0.0001). The regression equation of RItriQ = −000121 + 0.9988 × RImQ (r2 = 0.8377; P < 0.0001) is provided in Fig. 3B. Figure 3C displays the regression line between τwtriQ and τwmQ as being τwtriQ = −1.5709 + 1.0604 × τwmQ (r2 = 0.9641; P < 0.0001).

Figure 3
figure 3

Relations between RM (A), RI (B), and τw (C) calculated from the measured pressure and Qm (RMmQ, RImQ, and τwmQ; on the horizontal axes) and RM, RI, and τw calculated from the measured pressure and assumed Qtri (RMtriQ, RItriQ, and τwtriQ; on the vertical axes). Qm, measured aortic flow; Qtri, uncalibrated triangular flow; RM, wave reflection magnitude; RI, wave reflection index; τw, arterial wave transit time in the lower body circulation; NC, normal controls; CKD, rats with chronic kidney disease; type 1 DM, streptozotocin-induced diabetic rats; type 2 DM, streptozotocin–nicotinamide-induced diabetic rats.

Figure 4 presents a Bland–Altman plot for RM (A), RI (B), and τw (C), with a mean difference of −0.0328, −0.0126, and −0.2318 ms, respectively.

Figure 4
figure 4

Bland–Altman plots of RM (A), RI (B), and τw (C). Dashed lines represent averages; dotted lines denote 95% confidence intervals. τw, arterial wave transit time in the lower body circulation; RM, wave reflection magnitude; RI, wave reflection index; NC, normal controls; CKD, rats with chronic kidney disease; type 1 DM, streptozotocin-induced diabetic rats; type 2 DM, streptozotocin–nicotinamide-induced diabetic rats.

Figure 5 shows the effects of the experimental CKD and type 1 and type 2 DM on the arterial wave properties derived from the measured pressure and Qm, including RMmQ (5 A), RImQ (5B), and τwmQ (5 C). In comparison with the NC, the CKD rats exhibited a higher magnitude of pulse wave reflection, expressed in the form of RMmQ and RImQ. The CKD rats also exhibited shortened τwmQ. In addition, both diabetic groups exhibited a significant increase in arterial RMmQ and RImQ, with a diabetes-associated reduction in arterial τwmQ. The parameters calculated using Qtri for describing the effects of CKD and DM on arterial wave properties are provided in Fig. 5D (RMtriQ), 5E (RItriQ), and 5 F (τwtriQ). The CKD rats and both diabetic groups exhibited a deterioration in RMtriQ, RItriQ, and τwtriQ, which showed similar statistical significance to that of their measured counterparts (i.e., RMmQ, RImQ, and τwmQ).

Figure 5
figure 5

Effects of chronic kidney disease and type 1 and type 2 diabetes on RMmQ (A), RImQ (B), and τwmQ (C), calculated from the measured pressure and Qm, and their effects on RMtriQ (D), RItriQ (E), and τwtriQ (F), calculated from the measured pressure and assumed Qtri. Qm, measured aortic flow; Qtri, uncalibrated triangular flow; RM, wave reflection magnitude; RI, wave reflection index; τw, arterial wave transit time in the lower body circulation; NC, normal controls; CKD, rats with chronic kidney disease; type 1 DM, streptozotocin-induced diabetic rats; type 2 DM, streptozotocin–nicotinamide-induced diabetic rats.

Discussion

In 2006, Westerhof et al.8 demonstrated an accurate estimate of RM and RI obtained from the measurement of a single pressure pulse and an uncalibrated triangular flow pulse for ventricular ejection. The present study elaborates this concept by determining τw by using an aortic impulse response analysis. We discovered that in addition to wave reflection magnitude measures, the arterial τw in the lower body circulation could be approximately estimated using the measured aortic pressure alone in various diseased animals.

It is generally recognized that Zi can completely describe the physical properties of an arterial system4,11. Another method of characterizing arterial systems entails using the aortic impulse response function. Conceptually, the impulse response of any linear, time−invariant system, which the vascular system approximates4, may be considered as output resulting from the input of an infinitely narrow pulse of a unit area, termed an impulse. Thus, Fourier transformation of the impulse response generates input impedance, and inverse Fourier transformation of the impedance generates the impulse response12,13. Although the impulse response of the arterial system is a time−domain equivalent to its input impedance in the frequency domain, they emphasize different aspects of the system.

Regarding the study of the vascular impulse response, the input is an impulse of flow, and the output is the resulting pressure measured in the ascending aorta. In 1980, Sipkema et al.10 directly applied a flow impulse to the vasculature to study the impulse response of the arterial system. They discovered that the impulse response exhibited an initial sharp peak, followed by an exponential decay with two peaks superimposed on it. An alternative indirect method they employed to obtain the aortic impulse response involved using an inverse Fourier transformation of Zi. This was accomplished through the inverse transformation of Zi after being filtered by a Dolph–Chebychev weighting function12. The Dolph–Chebyshev filter is used to reduce spurious oscillations introduced by truncation of the impedance. Their results demonstrated strong agreement between the directly measured and indirectly derived impulse response functions of the arterial system.

For this study, the impulse response of the arterial system was calculated using an inverse Fourier transform of Zi by applying a method proposed by Laxminarayan et al.12. Figure 2 presents the aortic impulse response functions of a healthy rat derived from the measured pressure and Qm (2 A), and those calculated from the measured pressure and assumed Qtri (2B). The green curve displays the two discrete reflection peaks in the vascular impulse response, which represent pressure reflections linked to the effective reflection sites in the asymmetric T-tube model of the arterial tree14. There is no doubt that geometric and elastic tapering and branching of the mammalian arterial tree contribute to multiple reflection sites3,4. These multiple reflection sites result in diffuse reflections, which characterize the prolonged pressure decay10. The presence of two discrete reflection peaks in the vascular impulse response represents pressure reflections from two effective reflection sites14. These discrete reflections contribute to the oscillations of moduli and phase in the vascular impedance spectra. It is important to realize that there is no single anatomic structure or change located at these effective reflection sites, but rather they represent the summation of effects of multiple distance reflections. The effective upper body distal to the origin of the subclavian and brachiocephalic vessels generates the first reflection peak and the lower body distal to the descending aorta generates the second reflection peak10. Present evidence suggests that these larger vascular reflections probably originate at terminal arterioles15. Because the apparent time of the first peak is heavily influenced by early diffuse reflections15, we considered the second peak (long arrow in Fig. 2A,B) as the standard for the calculation of τw in the lower body circulation. The time of the initial peak (short arrow in Fig. 2A,B) was used as a reference.

According to the Moens and Korteweg formula16, as arterial stiffness increases, pulse wave velocity (c0) increases and thereby shortens the traveling time of the forward and reflected pressure waves. Being relatively independent to body shape3,4,11, arterial τw, which is inversely related to c0, was derived to represent the distensibility of aortas in the lower body circulation; the stiffer the aortic wall is, the shorter the arterial τw, and vice versa. The CKD rats and both diabetic groups exhibited a decline in aortic distensibility compared with the NC, as manifested by a reduction in τwmQ (Fig. 5C). An increase in aortic stiffness could also be reflected in the reduction in τwtriQ (Fig. 5F). A reduction in τw suggested that CKD and DM caused an early return of pulse wave reflection from the peripheral circulation. Both the CKD and DM contributed to a significant rise in RMmQ (Fig. 5A) and RImQ (Fig. 5B), which indicates heavy reflection intensity in the vasculature. Augmented RMtriQ (Fig. 5D) and RItriQ (Fig. 5E) were also observed in the CKD rats and both diabetic groups. Thus, changes in τw, RM, and RI, evaluated using either Qm or Qtri suggest that CKD and DM may modify the timing and magnitude of pulse wave reflection, resulting in an increase in the systolic workload imposed on the heart. These findings indicate that the measured aortic pressure alone, associated with an uncalibrated Qtri, can reveal arterial wave properties in various diseased animals.

This study has several limitations17. Because Zi cannot be measured in conscious animals, evaluating the effects of pentobarbital anesthesia on rats is impossible. The results reported here pertain only to the measurements made in anesthetized rats in an open-chest condition. This condition might have induced changes in the aortic pressure profiles and introduced reflex effects not found in ordinary conditions. The degree to which anesthesia and thoracotomy influence the pulsatile hemodynamics in rats is uncertain. However, studies conducted using other animals suggest that the effects are minor relative to the biological and experimental variability between animals18.

Conclusions

We propose a method for determining the arterial τw from the impulse response of Zi on the basis of the measured aortic pressure and an assumed triangular flow. The base of the uncalibrated Qtri was constructed with a duration set equal to the ejection time derived from measured pressure. After ejection commenced, the timing of the peak triangle was set at the first zero crossing (from above to below) on the fourth-order derivative of the aortic pressure wave. The findings indicate that in addition to wave intensity measurements, τw could be approximately calculated using the assumed Qtri, and exhibited strong correlation with that derived from Qm. The attractiveness of the study is that flow wave with triangular shape is derived from the measured pressure and that calibration of flow is not essential in the analysis. We suggest that aortic impulse response analysis can be used as an effective method for the estimation of arterial τw in the lower body circulation by using a single pressure pulse recording.

Methods

Animals and catheterization

Two-month-old male Wistar rats were randomly divided into four groups: (1) NC (n = 27), (2) CKD (n = 22), (3) type 1 DM (n = 22), and (4) type 2 DM (n = 11). Under anesthesia with sodium pentobarbital (50 mg kg−1; i.p.), CKD was induced by 5/6 subtotal nephrectomy (i.e., right nephrectomy and ligation of two branches of the left renal artery), according to the method by Floege et al.19. The levels of SCr and BUN were measured with an autoanalyzer (Model 7070, Hitachi Electronics Co., Ltd., Tokyo, Japan). Type 1 DM was induced using a single tail vein injection with 55 mg kg−1 of STZ (Sigma, St. Louis, MO, USA) in 0.1 M citrate buffer (pH 4.5) (Sigma, St. Louis, MO, USA)17. Type 2 DM was induced by administering intraperitoneally 180 mg kg−1 of NA (Sigma, St. Louis, MO, USA) 30 min before an intravenous injection of 50 mg kg−1 of STZ dissolved in 0.1 M citrate buffer (pH 4.5)20,21. The blood glucose level was determined using a SURESTEP Test Strip (Lifescan Inc., Milpitas, CA, USA) to confirm the development of hyperglycemia. Studies on changes in arterial mechanics were performed 8 weeks after the induction of CKD and DM. All rats were allowed free access to Purina chow and water and housed under 12-hour light/dark cycles. The experiments were conducted according to the Guide for the Care and Use of Laboratory Animals, and our study protocol was approved by the Animal Care and Use Committee of National Taiwan University.

The general surgical procedures and method used to measure the cardiovascular variables in the anesthetized rats were performed as described previously17. In brief, the rats were anesthetized using intraperitoneal sodium pentobarbital (50 mg kg−1), placed on a heating pad, intubated, and ventilated with a rodent respirator (Model 131, New England Medical Instruments, Medway, MA, USA). The chest was opened through the second intercostal space on the right side. An electromagnetic flow probe (100 series, internal circumference 8 mm, Carolina Medical Electronics, King, NC, USA) was positioned around the ascending aorta to measure pulsatile Qm. A high-fidelity pressure catheter (Model SPC 320, size 2 F, Millar Instruments, Houston, TX, USA) was used to measure pulsatile aortic pressure through the isolated carotid artery on the right side. An electrocardiogram (ECG) of lead II was recorded using a Gould ECG/Biotach amplifier (Cleveland, OH, USA). Selective aortic pressure and flow signals from 5–10 beats were averaged in the time domain by using the peak R-wave of the ECG as a fiducial point. The timing asynchronicity between the pressure and flow signals caused by the spatial distance between the flow probe and the proximal aortic pressure transducer was corrected using a time-domain approach, wherein the foot of the pressure waveform was realigned with that of the flow22. The resulting aortic pressure and flow signals were subjected to further vascular impedance analysis4,11,17.

Construction of the unknown flow wave with a triangular shape

The base of the unknown Qtri was constructed with a duration set equal to the ejection time derived from measured pressure8. The start and end time points of ejection were identified as the intersection of two tangential lines around the foot of the pressure wave (first vertical blue line in Fig. 1) and around the incisura (third vertical blue line in Fig. 1), respectively17. The timing of the peak triangle was derived from the fourth-order derivative of pressure waveform (pink curve in Fig. 1). After ejection commenced, the first zero crossing from above to below (second vertical blue line in Fig. 1) determined the peak triangle, which was close to peak of Qm8,23. Thus, the unknown flow wave was approximated by a triangular shape, represented by the green curve (Qtri).

Impulse response function curve

Zi was obtained from the ratio of ascending aortic pressure harmonics to the corresponding flow harmonics by using a standard Fourier series expansion technique4,11,17. Zc was computed by averaging the high-frequency moduli of Zi data points (fourth to tenth harmonics). The arterial τw was computed using the impulse response function of Zi10,15. This calculation was performed using an inverse Fourier transformation of Zi after multiplying the first 12 harmonics by a Dolph–Chebychev weighting function with order 2412,17. The green lines in Fig. 2A,B indicate that the Zc component of the vascular impulse response was removed. One-half of the time difference between the appearance of the second reflected peak (long arrow) and the initial peak (short arrow) in the impulse response function curve approximates the τw in the lower body circulation10,12.

Arterial wave separation analysis

Regarding the time domain, the following equations are used to calculate the forward pressure wave (Pf) and backward pressure wave (Pb):17,24

P(t) is the measured pressure wave, and Q(t) is either Qm or the assumed Qtri. As mentioned, Zi is the ratio of pressure and flow quantities. Thus, the product Zc × Q(t) in the preceding equations remains unaltered because the calculated Zc is twice as small when Q(t) is twice as large. This indicates that an absolute flow calibration is not required. With the measured aortic pressure, the forward and backward pressure waves calculated using Qm are illustrated in Fig. 2C, and those calculated using Qtri are shown in Fig. 2D. The arterial RM was then calculated as the ratio of |Pb| and |Pf|, i.e., RM = |Pb|/|Pf|7. The reflection index (RI) is defined as RI = |Pb|/(|Pf| + |Pb|).

Statistics

Results are expressed as the mean ± standard error (s.e.). An independent Student’s t test was performed to determine the statistical significance of the results for comparing the effects of CKD and both DM types on arterial wave properties with the NC. Statistical significance was assumed at the level of P < 0.05.

Additional Information

How to cite this article: Chang, R.-W. et al. Determining arterial wave transit time from a single aortic pressure pulse in rats: vascular impulse response analysis. Sci. Rep. 7, 40998; doi: 10.1038/srep40998 (2017).

Publisher's note: Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.