Abstract
Coiled polymer artificial muscles with both large tensile stroke and giant force generation are needed for practical applications in robotics, soft exosuits, and prosthesis. However, most polymer yarn artificial muscles cannot generate a large force or stress. Here, we report an inexpensive Twisted and Coiled Polymer artificial muscle (TCP) that performs both large isobaric and isometric contractions. This TCP can generate a tensile stroke of 20.1% and a specific work capacity of up to 1.3 kJ kg−1 during temperature changes from 20 to 180 °C. Moreover, the nylon yarn artificial muscle produced a reversible output stress of 28.4 MPa, which is 100 times larger than human skeletal muscle. A robot arm and a simple gripper were made to demonstrate the isobaric actuation and isometric actuation of our TCP muscle, repectivley. Thus, the polymer artificial muscles with dual-mode actuation show potential applications in the field of robotics, grippers, and exoskeletons and so on.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
1 Introduction
Artificial muscles, which can transfer other types of energies (such as thermal and electrothermal energy) to mechanical energy, have received extensive attention in multiple fields ranging from material science, mechanical and medical engineering as well as robotics [1]. Ideal artificial muscles should have a performance like high energy conversion efficiency, fast response, scalability, non-hysteretic, long-cycle life and low cost, and so on. Various types of artificial muscles such as pneumatic actuators [19], coating nylon fiber with conductive silver paint [20], and by twisting metal wire and fishing line simultaneously [ The monofilament nylon fiber was purchased from Statex Productions & Vertriebs GmbH (Shieldex PN# 260151011717 and 260151023534). Self-coiled nylon muscles were made by inserting twist into a nylon fiber. As shown in Fig. S1a, a nylon fiber was hung on a stepper motor, and a constant load was applied to the nylon fiber during the twisting process. To prevent the untwist of nylon yarn during actuation, it was torsionally tethered via a wood stick. By over-twisting, a fully coiled nylon muscle was made. A copper wire-wrapped coiled nylon fiber was made by wrap** a 50-μm-diameter copper wire with the coiled nylon fiber. To avoid the stroke restriction by copper wire, the wrap** direction was opposite to the coil direction (Fig. 2a). This thin copper wire has a negligible mechanical effect on the actuation. Unless otherwise indicated, the tensile stroke is defined as the length change during actuation divided by the length of the loaded muscle. The applied tensile stress is the constant force normalized to the yarn diameter of the fully twisted yarn. The generated stress was calculated using the generated force divided by the cross-sectional area of the coiled muscle. Spring index C is defined in spring mechanics as C = D/d, where d is the fiber diameter and D is the nominal coil diameter as measured by the fiber centerline. The morphology and structure of the coiled nylon yarn and the copper-wire-wrapped nylon yarn were obtained by scanning electron microscopy (SEM, model JSM-7800F, JEOL, Japan). The change in modulus and generated stress for the coiled nylon muscle with temperature was measured by thermomechanical analysis (TMA, TMA 7100, Hitachi, Japan). The change in the pitch of coiled nylon was observed by optical microscopy (DMi8, Leica, Germany). The temperature change of the coiled nylon muscle was recorded using a thermographic high-resolution system (T540, FLIR, United States). The mechanical properties of the nylon fiber were tested by a universal mechanical testing machine (5944, Instron, America). For thermally powered Twisted and Coiled Polymer (TCP) artificial muscles, the actuation mechanism is depicted in Fig. 1a. It illustrates that thermal expansion causes the yarn to untwist, which leads to yarn length contraction. Isobaric tensile actuation for thermally powered nylon 6,6 muscle was measured by thermal dynamic analysis (TMA). To achieve reversible actuation, the coiled nylon muscle has been thermally annealed at 150 °C for 0.5 h before actuation, and the working temperature was set from 20 to 180 °C at a rate of 10 °C min−1. As a result, the tensile stroke as a function of temperature for the coiled nylon muscle was obtained (Fig. 1b). Yarn muscle monotonically contracts with increasing temperature for most applied mechanical loads. Notably, if the applied load is smaller than the load used for coiling, adjacent coils are in contact, limiting contraction during actuation. Thus, for the applied load of 5.4 MPa, yarn muscle first contracts with increasing temperature until a peak value of 14.5% was achieved, and keeps no change when continue increasing temperature. Increasing load can separate adjacent coils and achieve larger actuation. Figure 1c shows the load dependence of tensile stroke for the coiled nylon muscles. The tensile stroke increases with increasing applied tensile stress until a maximum value of 20.1% was achieved under an optimal load of 10.7 MPa. With increasing applied load, the muscle’s initial length was stretched, leading to a decreased tensile stroke. The work capacity that nylon muscle generated during contraction monotonically increases with increasing applied tensile stress and reaches 1.3 J g−1 when the applied load was 31 MPa, which is 32 times that of mammal muscle [23]. From the aspect of natural muscle, the output performance is not only limited to the muscle length contraction, but also means that a force can be generated in isometric conditions without muscle length change [24]. When a nylon artificial muscle was thermally heated, the yarn muscle first absorbs thermal energy and then transmits the energy to the coiled structure. Consequently, an isometric force was generated. Isometric contraction is also an important parameter of a high-performance artificial muscle. To mimic the isometric contraction, a similar setup was employed (as illustrated in fig. S1c) where the sample length is fixed, and stress evolution could be recorded by the load cell when external stimulation was applied. In each experiment, the specimen was subjected to at least three consecutive thermal cycles where stress can be significantly produced in heating and elapse in cooling. By applying a pre-strain of 10%, nylon muscle produced initial stress (σI-min), and the stress increases with increasing temperature until a maximum value (σI-max) was achieved (Fig. 1d). With an increase in pre-strains, both the maximum and minimum isometric stress increase accordingly (fig. S2), from 4.1 to 10.1 MPa of σI-min. The generated stress was calculated by the difference between σI-max and σI-min. For each pre-strain, σI-min and σI-max stay at the same level despite the number of cycles. With an increase in strains, the value and variation mode of stress is observed to strongly depend on the pre-strains, reflecting the effect of crystallization behavior and thermodynamic properties on contraction performance [25]. The stress generation as a function of the applied pre-strain was shown in Fig. 1e. It is worth noting that nylon muscle can produce more than 28 MPa stress under 25% pre-strain, which is more than 3.5 times than for CNT-NCY hybrid muscle [26] and 100 times than for human muscle [23] (∼0.3 MPa). Although self-coiled nylon muscles can achieve excellent actuation performance, they cannot be powered by electricity due to their non-conductivity. By wrap** coiled nylon fiber with a copper wire, we made an electrothermally powered nylon muscle. To avoid the stroke restriction by copper wire, the wrap** direction was opposite to the coil direction (Fig. 2a). Also, the winding density (the number of winding turns divided by the total muscle length) of copper wire would affect the uniformity of thermal energy on the yarn muscle that delivered by electrical power. Figure 2b shows the tensile stroke as a function of time under different applied loads. During a heating–cooling cycle, muscle contracts to a maximum value within 4.5 s, and provide a large stroke rate of 2.2% s−1. The load dependence of the tensile stroke and work capacity for electrothermally powered nylon muscle has also been obtained (Fig. 2c). By applying a 0.28 W cm−1 square-wave voltage, nylon muscle can generate a maximum tensile stroke of 12.1% and a work capacity of 0.8 J g−1, respectively. After the wrap** process, we measured the real-time temperature using a thermal camera during the nylon muscle contraction, which is shown in Fig. 2d. It depicts that the nylon yarn muscle was uniformly heated by electrical power. In addition, the real-time temperature of yarn muscle exhibits the same trend with tensile stroke (Fig. 2e). The actuation performance for electrothermally powered nylon muscle can be improved by varying actuation frequency, duty cycle, and input power. Figure 3a demonstrates the tensile stroke changes with time under different applied frequencies. The applied tensile stress and power were 8.6 MPa and 0.27 W cm−1 square wave, respectively. At a low frequency of 0.02 Hz, nylon muscle generates a maximum tensile stroke of 11.6%. While at a high frequency of 0.5 Hz, nylon muscle contracts insufficiently in the first cycle and quickly increased to the stabilized stroke after a few cycles. Due to the limited time to cool at high frequencies, nylon muscle cannot release back to its original length and only actuated at high-temperature regions. Consequently, muscle stroke decreased with the increase in frequency (Fig. 3b). Besides, the yarn’s diameter also affects the actuation for different frequencies, especially for high frequencies. As shown in Fig. S6b, the cooling time (defined as the time needed to reduce the tensile stroke by 90%. [3]) for an 80-μm-diameter nylon muscle (1.9 s) is much shorter than for a 200-μm-diameter nylon muscle (7.2 s), indicating that muscles with a small diameter can be cycled at a higher frequency than for a larger one (Fig. S6b). Note that the contractile rate (tensile stroke divided by the contractile time) and release rate (tensile stroke divided by the release time) are not always matched. Thus, the duty cycle would also affect the actuation performance. Fig. S3a shows the duty cycle dependence of the tensile stroke for a coiled nylon muscle measured at a 0.05 Hz, 0.28 W cm−1 square-wave power. At a low duty cycle of 10%, the heating time is too short, which limited the input electrothermal energy, leading to a small contractile stroke. At a high duty cycle of 90%, the cooling time is too short, which made yarn muscle fail to return to its original state, causing the decrease of absolute tensile stroke. Consequently, an appropriate duty cycle is necessary to achieve the largest tensile actuation. After varying different duty cycles, we found that the maximum tensile stroke is 12% at the optimal duty cycle of 50%. Thus, the tensile stroke increased first with the increment of the duty cycle and then decreased after it reached the maximum value, as shown in Fig. S3b. More importantly, the input power and cycle stability of muscle are significant for practice use [27]. We have measured the dependence of tensile stroke on the input power density, which is illustrated in Fig. 3c, d. The tensile stroke increases almost linearly and reversibly with the input power density. Typically, the tensile stroke increases from 4.1% at an input power of 0.16 W cm−1 to 12.1% at an input power of 0.27 W cm−1. The cycle stability of electrothermally powered copper wire-wrapped nylon muscle has also been measured. As shown in Fig. 3e, the nylon muscle provides a very stable contraction stroke for at least 1000 cycles when a 0.2 Hz, 50% duty cycle, 0.25 W cm−1 square-wave power was applied. Thus, the electrothermally powered nylon muscle are feasible material for the applications of soft robotics and exosuits. In addition, we have demonstrated the potential application of a copper-wire wrapped nylon artificial muscle lifting heavy weight when electrothermally driven at a 0.05 Hz, 50% duty cycle, and 6.5 V square-wave voltage (shown in Movie S1). Similar to the self-coiled nylon muscle, the generated isometric stress of a coiled, copper wire-wrapped nylon muscle has been investigated. The muscle was fixed in a tensile dynamometer with two ends clamped and connected by an electrical wire to a power supply (Fig. S1b). Fig. S4a shows the time dependence of the generated stress of the coiled, copper wire-wrapped nylon muscle under different applied preload strains. The input electrical power was 0.05 Hz, 0.27 W cm−1 square-wave with 50% duty cycle. When the voltage was applied to the nylon muscle, the generated isometric stress increased rapidly and then sluggishly increase to the maximum value. When the applied voltage was switched to 0 V, the generated stress gradually decreased to the initial stress. Figure 4a shows that the generated isometric stress first increased with the increase in the pre-strain and then reached a maximum value of 28.4 MPa at the pre-strain of 25%.2 Experimental Sections
2.1 Fabrication of Self-Coiled Nylon Muscles and Copper Wire-Wrapped Coiled Nylon Muscles
2.2 Characterizations
3 Results and Discussion
3.1 Thermally Powered Self-Coiled Nylon Muscles
3.2 Electrothermally Powered Copper Wire-Wrapped Coiled Nylon Muscles
3.2.1 Isobaric Actuation
3.2.2 Isometric Actuation