Abstract
A fluorescence “turn-off” and color “turn-on” probe for late IB metal ions (Fe3+/Co2+/Ni2+/Cu2+/Zn2+) was developed based on rhodamine B. The probe was synthesized by condensation between rhodamine B and 8-hydroxyjulolidine-9-carboxaldehyde, which provided excellent selectivity function for late IB metal ions detection. It binds Cu2+ in a 1:1 stoichiometry in acetonitrile solution. This probe displays distinct color and fluorescence change upon the addition of late IB metal ions and little interference with other biologically relevant metal ions. Limit of detection for Cu2+, Fe3+, and Co2+ is higher than that of Zn2+ and Ni2+. In addition, the limit of detection toward Cu2+ is about 312 times lower than the World Health Organization (WHO) recommended level in drinking water.
Similar content being viewed by others
Refrerences
J. Mao, L. Wang, W. Dou, X. Tang, Y. Yan, and W. Liu, Org. Lett., 9, 4567 (2007).
F. Yan, D. Cao, N. Yang, Q. Yu, M. Wang, and L. Chen, Sensors Actuat. B, 162, 313 (2012).
R. P. Haugland, “The Handbook: A Guide to Fluorescent Probes and Labeling Technologies”, 10th ed., Molecular Probes, Invitrogen Corp., Karlsbad, CA, 2005.
C. Wu, Q.-N. Bian, B.-G. Zhang, X. Cai, S.-D. Zhang, H. Zheng, S.-Y. Yang, and Y.-B. Jiang, Org. Lett., 14, 4198 (2012).
M. Tian, X. Peng, J. Fan, J. Wang, and S. Sun, Dyes Pigments, 95, 112 (2012).
Q.-J. Ma, H.-P. Li, F. Yang, J. Zhang, X.-F. Wu, Y. Bai, and X.-F. Li, Sensors and Actuators B, 166, 68 (2012).
P. Du and S. J. Lippard, Inorg. Chem., 49, 10753 (2010).
X. Zhang, Y. Shiraishi, and T. Hirai, Org. Lett., 9, 5039 (2007).
X. Chen, S.-W. Nam, M. J. Jou, Y. Kim, S.-J. Kim, S. Park, and J. Yoon, Org. Lett., 10, 5235 (2008).
Y. H. Lee, M. H. Lee, J. F. Zhang, and J. S. Kim, J. Org. Chem., 75, 7159 (2010).
M. Xu, S. Wu, F. Zeng, and C. Yu, Langmuir, 26, 4529 (2010).
D. Zhang, M. Li, M. Wang, J. Wang, X. Yang, Y. Ye, and Y. Zhao, Sensors and Actuators B, 177, 997 (2013).
Z. Yang, M. She, B. Yin, J. Cui, Y. Zhang, W. Sun, J. Li, and Z. Shi, J. Org. Chem., 77, 1143 (2012).
A. J. Weerasinghe, C. Schmiesing, S. Varaganti, G. Ramakrishna, and E. Sinn, J. Phys. Chem. B, 114, 9413 (2010).
J. Fan, P. Zhan, M. Hu, W. Sun, J. Tang, J. Wang, S. Sun, F. Song, and X. Peng, Org. Lett., 15, 492 (2013).
J. Yin, X. Ma, G. Wei, D. Wei, and Y. Du, Sensors and Actuators B, 177, 213 (2013).
M. Kumar, N. Kumar, V. Bhalla, H. Singh, P. R. Sharma, and T. Kaur, Org. Lett., 13, 1422 (2011).
P. Mahato, S. Saha, E. Suresh, R. D. Liddo, P. P. Parnigotto, M. T. Conconi, M. K. Kesharwani, B. Ganguly, and A. Das, Inorg. Chem., 51, 1769 (2012).
J. Y. Kwon, Y. J. Jang, Y. J. Lee, K. M. Kim, M. S. Seo, W. Nam, and J. Yoon, J. Am. Chem. Soc., 127, 10107 (2005).
H. Kim, S. Lee, J. Lee, and J. Tae, Org. Lett., 12, 5342 (2010).
A. I. Vogel, “Textbook of Practical Organic Chemistry”, pp.397–403, Singapore Publishers Ltd., Singapore, 1994.
X.-F. Yang, X.-Q. Guo, and Y.-B. Zhao, Talanta, 57, 883 (2002).
WHO, “WHO Guidelines Values for Chemicals That are of Health Significance in Drinking Water”, Guidelines for Drinking Water Quality, 3rd ed., Geneva.
EU, “Council Directive 98/83/EC on the Quality of Water Intended for Human Consumption”, Official Journal of the European Communities, pp. L330/32–L330/54, 1998.
National Water Quality Management Strategy, Australian Drinking Water Guidelines 6, 2004.
Y. Zhao, B. Zheng, J. Dua, D. **ao, and L. Yang, Talanta, 85, 2194 (2011).
J. Wang, L. Long, D. **e, and X. Song, Sensors Actuat. B, 177, 27 (2013).
Author information
Authors and Affiliations
Corresponding authors
Rights and permissions
About this article
Cite this article
Li, X., Li, Y., Guo, Z. et al. A highly selective rhodamine based color turn on and fluorescence turn off sensor toward late IB metal ions. Fibers Polym 15, 914–917 (2014). https://doi.org/10.1007/s12221-014-0914-4
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12221-014-0914-4