A simple closure method for a mechanical aortic valve in left ventricular assist device implantation

  • How to Do It
  • Published:
General Thoracic and Cardiovascular Surgery Aims and scope Submit manuscript

Abstract

Because a mechanical aortic valve is a contraindication for the implantation of left ventricular assist device, complicated additional procedures such as a replacement with a bioprosthesis and a closure of the left ventricular outflow tract are required to implant the device. Among such procedures, a sandwich plug technique using vascular clips is one of the simple and feasible procedures. However, this technique requires an off-label use of vascular clips within the aorta that could be associated with a risk of dislodgement and embolization. Thus, we developed a modified sandwich technique without using vascular clips, where the valve leaflets were fixed in the closed position using felt patches and sutures instead of vascular clips. This modified technique is a simple and secure method to close the mechanical aortic valve with the minimum use of artificial materials.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
EUR 32.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or Ebook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

Similar content being viewed by others

References

  1. Dranishnikov N, Stepanenko A, Potapov EV, Dandel M, Siniawsli H, Mladenow A, et al. Simultaneous aortic valve replacement in left ventricular assist device recipients: single-center experience. Int Artif Organs. 2012;35:489–94.

    Article  Google Scholar 

  2. Pelletier MP, Chang CP, Vagelos R, Robbins RC. Alternative approach for use of a left ventricular assist device with a thrombosed prosthetic valve. J Heart Lung Transplant. 2002;21:402–4.

    Article  Google Scholar 

  3. Ahn H, Granfeldt H, Hubbert L, Peterzen B. Long-term left ventricular support in patients with a mechanical aortic valve. Scand Cardiovasc J. 2013;47:236–9.

    Article  CAS  Google Scholar 

  4. Cohn WE, Frazier OH. The sandwich plug technique: simple, effective, and rapid closure of a mechanical aortic valve prosthesis at left ventricular assist device implantation. J Thorac Cardiovasc Surg. 2011;142:455–7.

    Article  Google Scholar 

Download references

Funding

None.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Satoru Wakasa.

Ethics declarations

Conflict of interest

The authors declare that they have no conflicts of interest.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ishigaki, T., Wakasa, S. A simple closure method for a mechanical aortic valve in left ventricular assist device implantation. Gen Thorac Cardiovasc Surg 70, 677–679 (2022). https://doi.org/10.1007/s11748-022-01812-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11748-022-01812-8

Keywords

Navigation