Log in

Use of Corrosion Control Device to Control Reagent Water Treatment of Heating Networks

  • Published:
Materials Science Aims and scope

Testing of the reagent method of water treatment with the use of corrosion control devices was performed at the district boiler house of Kyiv city. Corrosion rate probes were installed on the straight and return pipelines of the heating network, and on the feed line. The anti-scale efficiency of the reagent was determined by measuring the change in the hardness of water before and after the heating equipment. Corrosion monitoring showed that the corrosion rate in the heating network is maintained at 0.1 mm/year. The corrosion rate on the feed line due to reagent water treatment was reduced to 0.03 mm/year in non-deaerated water. The calculation of economic efficiency has shown that the reagent method of water treatment for heating networks is by 13% cheaper than traditional approach and can serve as an alternative to the traditional one, especially regarding energy conservation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
EUR 32.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or Ebook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.
Fig. 2.
Fig. 3.
Fig. 4.
Fig. 5.

Similar content being viewed by others

References

  1. G. S. Vasyliev, O. V. Potapenko, and V. V. Oliinyk, “The use of a phosphorus-containing inhibitor to protect against corrosion of boiler equipment in systems with contact water heaters,” Physicochemical Mechanics of Materials [in Ukrainian], Special Is. 11, 243–249 (2016).

  2. M. Saremi, C. Dehghanian, M.M. Sabet, “The effect of molybdate concentration and hydrodynamic effect on mild steel corrosion inhibition in simulated cooling water,” Corros. Sci., 48, Is. 6, 1404–1412 (2006); https://doi.org/10.1016/j.corsci.2005.06.009.

  3. K. Sabet Bokati, C. Dehghanian, and S. Yari, “Corrosion inhibition of copper, mild steel and galvanically coupled copper-mild steel in artificial sea water in presence of 1H-benzotriazole, sodium molybdate and sodium phosphate,” Corros. Sci., 126, 272–285 (2017); https://doi.org/10.1016/j.corsci.2017.07.009.

  4. Z. Belarbi, B. Sotta, L. Makhloufi, B. Tribollet, and J. Gamby, “Modelling of delay effect of calcium carbonate deposition kinetics on rotating disk electrode in the presence of green inhibitor,” Electrochim. Acta, 189, 118–127 (2016); https://doi.org/10.1016/j.electacta.2015.12.089.

  5. Z. Mohammadi, and M. Rahsepar, “The use of green Bistorta Officinalis extract for effective inhibition of corrosion and scale formation problems in cooling water system,” J. of Alloys and Compounds, 770, 669–678 (2019); https://doi.org/10.1016/j.jallcom.2018.08.198.

  6. M. Chaussemier, E. Pourmohtasham, D. Gelus, N. Pécoul, H. Perrot, J. Lédion, H. Cheap-Charpentier, and O. Horner, “State of art of natural inhibitors of calcium carbonate scaling. A review article,” Desalination, 356, 47–55 (2015); https://doi.org/10.1016/j.desal.2014.10.014.

  7. D. Hasson, H. Shemer, and A. Sher, “State of the art of friendly “green” scale control inhibitors: A review article,” Industrial and Engineering Chemistry Research, 50, Is. 12, 7601–7607 (2011); https://doi.org/10.1021/ie200370v.

  8. J. Li, M. Tang, Z. Ye, L. Chen, and Y. Zhou, “Scale formation and control in oil and gas fields: A review,” J. of Dispersion Science and Technology, 38, Is. 5, 661–670 (2017); https://doi.org/10.1080/01932691.2016.1185953.

  9. R. Menzri, S. Ghizellaoui, and M. Tlili, “Calcium carbonate inhibition by green inhibitors: thiamine and pyridoxine,” Desalination, 404, 147–154 (2017); https://doi.org/10.1016/j.desal.2016.11.005.

  10. V. Vorobyova, O. Chygyrynetś, M. Skiba, I. Kurmakova, and O. Bondar, “Self-assembled monoterpenoid phenol as vapor phase atmospheric corrosion inhibitor of carbon steel,” Int. J. of Corrosion and Scale Inhibition, 6, Is. 4, 485–503 (2017); https://doi.org/10.17675/2305-6894-2017-6-4-8.

  11. O. E. Chygyrynets’, V. I. Vorobyova, G. Y. Galchenko, and I. G. Roslik, “Investigation of the efficiency of inhibitors of atmospheric corrosion,” Metallurgical and Mining Industry [in Ukrainian], 4, No. 2, 100–106 (2012).

  12. Cormon Data Transmitters and Receivers. Available at: http://www.teledyneoilandgas.com/_document/TDY_317_DataTransmitter_IFS344988_RevB_1.

  13. MS1000 Corrosion Meter. Available at: http://www.alspi.com/manuals/ms1000manual.pdf.

  14. S. G. Polyakov, and Yu. G. Kotlov, “Using corrosion meters of polarization resistance in laboratory and industrial practice,” Sov. Mater. Sci., 24, No. 5, 528–529 (1989); https://doi.org/10.1007/BF00722019.

    Article  Google Scholar 

  15. H. S. Vasyl’ev, and Y. S. Herasymenko, “Corrosion meters of new generation based on the improved method of polarization resistance,” Mater. Sci., 52, No. 5, 722–731 (2017); https://doi.org/10.1007/s11003-017-0015-9.

  16. G. Vasyliev, “Polarization resistance measurement in tap water: the influence of rust electrochemical activity,” J. of Mat. Eng. and Perform., 26, Is. 8, 3939–3945 (2017); https://doi.org/10.1007/s11665-017-2813-5.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to G. S. Vasyliev.

Additional information

Translated from Fizyko-Khimichna Mekhanika Materialiv, Vol. 59, No. 1, pp. 71–78, January–February, 2023.

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Vasyliev, G.S., Herasymenko, Y.S. Use of Corrosion Control Device to Control Reagent Water Treatment of Heating Networks. Mater Sci 59, 69–76 (2023). https://doi.org/10.1007/s11003-023-00745-8

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11003-023-00745-8

Keywords

Navigation