To keep the accredited category for the gamma spectrometry test in our laboratory, the efficiency curves of a HPGe detector for soil sample in Marinelli geometry were determined by “efficiency transfer” principle via the ANGLE3 commercial software and Monte Carlo simulations via MCNP5 and GEANT4. The efficiency obtained from experimental measurement of point standard sources was used as a reference efficiency curve for the input of ANGLE3 software as well as for correction of simulation codes of MCNP5 and GEANT4. The results of the efficiency for soil sample in Marinelli beaker obtained from the MCNP5 and GEANT4 were compared with the efficiency obtained from the ANGLE3 software. Moreover, the trueness of the detector efficiency obtained in this work was evaluated by the radioactivity measurement of 40K, 137Cs, 232Th and 238U in an IAEA reference material.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
EUR 32.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or Ebook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Daza MJ, Quintana B, Garcia-Talavera M, Fernandez F (2001) Efficiency calibration of a HPGe detector in the [46.54–2000] keV energy range for the measurement of environmental samples. Nucl Instrum Methods 470:520–532

    Article  CAS  Google Scholar 

  2. Geant4 and Collaboration, Geant4 Users guide for application deverlopers. Version geant4.10.00. 2013

  3. Nikolic J, Vidmar T, Jokovic D, Rajacic M, Todorovic D (2014) Calculation of HPGe efficiency for environmental samples: comparison of EFFTRAN and GEANT4. Nucl Instrum Methods 763:347–353

    Article  CAS  Google Scholar 

  4. Morera-Gomez Y, Cartas-Aguila HA, Alonso-Hernandez CM (2015) Application of the Monte Carlo efficiency transfer method to an HPGe detector with the purpose of environmental samples measurement. Appl Radiat Isot 97:59–62

    Article  CAS  Google Scholar 

  5. Li Qi, Wang S, Zhao Y, Fan Y, Zhang X, Jia H, Zeng Z (2021) Geant4 simulation of detection efficiency and self-attenuation effect of Beta particles for radioxenon measurement using beta-gamma coincidence equipment. Radioact Radiochem 330:325–332

    CAS  Google Scholar 

  6. User guide, ANGLE3 Semiconductor Detector Efficiency Calculations. Ortect

  7. Stanic G, Nikolove J, Tucakovic I, Mrda D, Todorovic N, Grahek Z, Coha I, Vranicar A (2019) Angle vs. LabSOCS for HPGe efficiency calibration. Nucl Instrum Methods 920:81–87

    Article  CAS  Google Scholar 

  8. Jovanovic S, Dlabac A, Mihaljevic N (2010) ANGLE v2.1—new version of the computer code for semiconductor detector gamma-efficiency calculations. Nucl Instrum Methods Phys Res Sect A 622:385–191

    Article  CAS  Google Scholar 

  9. Vidmar T, Çelik N, Cornejo Díaz N, Dlabac A, Ewa IOB, Carrazana González JA, Hult M, Jovanovic S, Lépy MC, Mihaljevic N, Sima O, Tzika F, Jurado Vargas M, Vasilopoulou T, Vidmar G (2010) Testing efficiency transfer codes for equivalence. Appl Radiat Isot 68:355–359

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Van Doanh Ho.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ho, V.D., Phan, B.Q.H., Pham, N.S. et al. Comparison of efficiency calibration techniques of HPGe detector for radioactivity measurement of soil sample in Marinelli geometry. J Radioanal Nucl Chem 331, 1361–1365 (2022). https://doi.org/10.1007/s10967-021-08187-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10967-021-08187-9

Keywords

Navigation