Abstract
X-ray inspection of ball grid arrays (BGAs) is typically performed at one or more viewing angles to examine adhesion sites for errors such as voids, joint cracking, or head-in-pillow. During this inspection process, the circuit board assembly is subject to ionizing radiation exposure, which can cause trapped charge within oxide layers of semiconductor devices. Some x-ray machines allow for programmable inspection routines, which could be used to optimize radiation exposure to semiconductor components. Using Monte Carlo methods, x-ray inspection of a BGA was simulated to determine a range of acceptable viewing angles. Dose rates to circuit board components were estimated at each inspection angle to determine the view resulting in optimized radiation exposure. Results showed that for each BGA, the maximum unobstructed viewing times without exceeding a 5 Gy dose limit to a single part ranged from 82 to 94 min. Using a radiation cost function method, optimized viewing across all components was found. It was observed that for a consistent dose limit applied to silicon-based components, performing inspection with BGAs facing the x-ray source was optimal. A third method was applied, assigning individual dose limits based on empirical data from the NASA Goddard Space Flight Center radiation database. This method showed that optimized viewing maximizes the distance between the radiation source and highly sensitive components. It was also observed that cumulative effects from viewing two BGAs will influence viewing angles, causing the optimal view of one BGA to exist nearly 180\(^\circ \) from the other.
Similar content being viewed by others
Data Availability
Not applicable
References
Holbert, K.E.: Electromagnetic: X-rays gamma rays subatomic particles: protons neutrons electrons pions muons not all radiation is equal
Mcclure, J., Tye, C., Hager, L., Tanner, R.: Radiation Metrology Report 78211S Evaluation of the radiation output of the Nordson DAGE XD7600NT x-ray sets that incorporate NT100 and NT500 x-ray sources - SUMMARY
Goorley, T., James, M., Booth, T., Brown, F., Bull, J., Cox, L., Durkee, J., Elson, J., Fensin, M., Forster, R., et al.: Initial mcnp6 release overview. Nucl. Technol. 180(3), 298–315 (2012)
Brown, F., Kiedrowski, B., Bull, J., Goorley, J., Hughes, H., James, M.: Advances in the Development and Verification of MCNP5 and MCNP6 (2011)
SolidWorks. Dassault Systems, Vélizy-Villacoublay, France (2017)
Pfeifer, M., Bahadori, A., Casburn, J., Dodson, M., McNeil, W., Porter, J., Simerl, N., Strahler, R.: Validation of radiation transport methods for ball grid array inspection systems, pp. 621–624 (2020). https://doi.org/10.13182/T32413
Pfeifer, M., Simerl, N., Porter, J., McNeil, W., Bahadori, A.: X-Ray Inspection Model Validation with Physical Dosimetry. J. Non-destruct. Eval (2022)
AMPTEK, Inc.: X-123 CdTe Complete X-Ray and Gamma Ray Spectrometer. http://amptek.com/products/x-123-cdte-complete-x-ray-gamma-ray-spectrometer-with-cdte-detector/ (2018)
Poludniowski, G., Landry, G., DeBlois, F., Evans, P., Verhaegen, F.: Spekcalc: a program to calculate photon spectra from tungsten anode x-ray tubes. Phys. Med. Biol. 54(19), 433 (2009)
Pfeifer, M., Simerl, N., Strahler, R., Casburn, J., Porter, J., McNeil, W., Bahadori, A.: Methods for estimating X-ray machine output through measurement and simulation. Appl. Radiat. Isot. (2022)
Bernard, D., Lane, R., Blish, R.: Considerations for Minimizing Radiation Doses to Components during X-ray Inspection. Technical report, Buckinghamshire (2022)
GSFC Radiation Data Base. https://radhome.gsfc.nasa.gov/radhome/RadDataBase/RadDataBase.html
Topper, A.D., Lauenstein, J.-M., Wilcox, E.P., Berg, M.D., Campola, M.J., Casey, M.C., Wyrwas, E.J., OBryan, M.V., Carstens, T.A., Fedele, C.M., Forney, J.D., Kim, H.S., Osheroff, J.M., Phan, A.M., Chaiken, M.F., Cochran, D.J., Pellish, J.A., Majewicz, P.J.: NASA Goddard Space Flight Center’s Compendium of Radiation Effects Test Results (2020)
Campola, M.J., Cochran, D.J., Boutte, A.J., Chen, D., Gigliuto, R.A., LaBel, K.A., Pellish, J.A., Ladbury, R.L., Casey, M.C., Wilcox, E.P., OBryan, M.V., Lauenstein, J.-M., Violette, D., Xapsos, M.A.: Compendium of Current Total Ionizing Dose and Displacement Damage for Candidate Spacecraft Electronics for NASA
Casey, M., Phan, A., Topper, A.: HSYE-117RH Voltage Linear Regulator Total Ionizing Dose Test Report (2019)
Acknowledgements
The authors would like to thank the Nuclear Regulatory Commission Fellowship program for additional support.
Funding
This work was funded by the Department of Energy’s Kansas City National Security Campus, operated by Honeywell Federal Manufacturing & Technologies, LLC under contract number DE-NA0002839. The computing for this project was performed on the Beocat Research Cluster at Kansas State University, which is funded in part by NSF grants CNS-1006860, EPS-1006860, EPS-0919443, ACI-1440548, CHE-1726332, and NIH P20GM113109.
Author information
Authors and Affiliations
Contributions
Michael P. Pfeifer - Methodology, Software, Validation, Data curation, Writing – original draft. Nathanael Simerl – Software, Data curation, Writing – review & editing. John Porter – Funding acquisition. Walter J. McNeil – Supervision, Writing – review & editing. Amir A. Bahadori – Conceptualization, Supervision, Writing – review & editing.
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no Conflict of interest.
Ethics Approval and Consent to Participate
Not applicable
Consent for Publication
Informed consent was obtained from all individual participants included in the study.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Pfeifer, M.P., Simerl, N., Porter, J. et al. Optimized Viewing Techniques to Minimize Radiation Damage From X-ray Imaging Systems. J Nondestruct Eval 43, 50 (2024). https://doi.org/10.1007/s10921-024-01060-1
Received:
Accepted:
Published:
DOI: https://doi.org/10.1007/s10921-024-01060-1