Log in

Distribution of ultrasound cyclo plasty probe models in Chinese patients with glaucoma

  • Original Paper
  • Published:
International Ophthalmology Aims and scope Submit manuscript

Abstract

Purpose

To investigate the distribution of ultrasound cyclo plasty (UCP) probe models in Chinese patients with glaucoma.

Methods

Patients needing glaucoma surgery were recruited at Zhongshan Ophthalmic Center from January 2019 to December 2019. Patient demographics were recorded and analyzed. Visual acuity, intraocular pressure (IOP), retinal nerve fiber layer (RNFL), mean defect of visual field (MD), ocular axial length (AL) and horizontal corneal diameter (white to white, WTW) of eyes with glaucoma were measured. In addition, the UCP probe models were calculated using a nomogram tool and two ocular anatomical parameters: WTW and AL.

Results

A total of 1281 patients (2000 eyes) were included in the study, including 559 males (43.64%) and 722 females (56.36%). The age of the patients ranged from 18 to 91 years, with a mean age of 61.43 ± 12.21 years. IOP ranged from 22.0 to 60.0 mmHg, with a mean of 26.17 ± 3.52 mmHg. The mean AL and WTW were 22.96 ± 1.43 (ranging from 19.07 to 35.00) and 11.55 ± 0.50 (ranging from 9.6 to 13.7), respectively. According to the results calculated by the nomogram tool, Chinese patients’ eyes mainly adapted to Model 12, with a percentage of 69.05%. Model 13 and Model 11 were suitable for 26.65% and 3.35% of the patients, respectively. A total of 0.95% of Chinese patients did not have a suitable probe model.

Conclusion

For Chinese patients who needed glaucoma surgery, UCP probe models were mainly attributed to Model 12, followed by Model 13, and Model 11 was the least used.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
EUR 32.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or Ebook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price includes VAT (France)

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

Data availability

The data used to support the findings of this study are available from the corresponding author upon request.

References

  1. Quigley HA, Broman AT (2006) The number of people with glaucoma worldwide in 2010 and 2020. Brit J Ophthalmol 90(3):262–267

    Article  CAS  Google Scholar 

  2. Blumberg D, Skaat A, Liebmann JM (2015) Emerging risk factors for glaucoma onset and progression. Prog Brain Res 221:81–101

    Article  PubMed  Google Scholar 

  3. Benson MT, Nelson ME (1990) Cyclocryotherapy - a Review of Cases over a 10-Year Period. Brit J Ophthalmol 74(2):103–105

    Article  CAS  Google Scholar 

  4. Kirwan JF, Shah P, Khaw PT (2002) Diode laser cyclophotocoagulation - Role in the management of refractory pediatric glaucomas. Ophthalmology 109(2):316–323

    Article  PubMed  Google Scholar 

  5. Mielke J, Schlote T (2004) Subconjunctival anaesthesia using cocaine or mepivacaine for cyclocryotherapy in advanced glaucoma. Klin Monatsbl Augenh 221(1):24–28

    Google Scholar 

  6. Giannaccare G, Sebastiani S, Campos EC (2018) Ultrasound cyclo plasty in eyes with glaucoma. Jove-J Vis Exp 131:e56192

    Google Scholar 

  7. Posarelli C, Covello G, Bendinelli A, Fogagnolo P, Nardi M, Figus M (2019) High-intensity focused ultrasound procedure: The rise of a new noninvasive glaucoma procedure and its possible future applications. Surv Ophthalmol 64(6):826–834

    Article  PubMed  Google Scholar 

  8. Aptel F, Charrel T, Lafon C, Romano F, Chapelon JY, Blumen-Ohana E et al (2011) Miniaturized high-intensity focused ultrasound device in patients with glaucoma: a clinical pilot study. Invest Ophthalmol Vis Sci 52(12):8747–8753

    Article  PubMed  Google Scholar 

  9. Denis P, Aptel F, Rouland JF, Nordmann JP, Lachkar Y, Renard JP et al (2015) Cyclocoagulation of the ciliary bodies by high-intensity focused ultrasound: a 12-month multicenter study. Invest Ophthalmol Vis Sci 56(2):1089–1096

    Article  PubMed  Google Scholar 

  10. Leshno A, Rubinstein Y, Singer R, Sher I, Rotenstreich Y, Melamed S et al (2020) High-intensity focused ultrasound treatment in moderate glaucoma patients: results of a 2-year prospective clinical trial. J Glaucoma 29(7):556–560

    Article  PubMed  Google Scholar 

  11. Giannaccare G, Pellegrini M, Bernabei F, Urbini L, Bergamini F, Ferro Desideri L et al (2021) A 2-year prospective multicenter study of ultrasound cyclo plasty for glaucoma. Sci Rep 11(1):12647

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  12. Figus M, Posarelli C, Nardi M, Stalmans I, Vandewalle E, Melamed S et al (2021) Ultrasound cyclo plasty for treatment of surgery-naive open-angle glaucoma patients: a prospective multicenter 2-year follow-up trial. J Clin Med 10(21):4982

    Article  PubMed  PubMed Central  Google Scholar 

  13. Wang RX, Wang T, Li N (2020) A comparative study between ultrasound cycloplasty and cyclocryotherapy for the treatment of neovascular glaucoma. J Ophthalmol. https://doi.org/10.1155/2020/4016536

    Article  PubMed  PubMed Central  Google Scholar 

  14. Melamed S, Goldenfeld M, Cotlear D, Skaat A, Moroz I (2015) High-intensity focused ultrasound treatment in refractory glaucoma patients: results at 1 year of prospective clinical study. Eur J Ophthalmol 25(6):483–489

    Article  PubMed  Google Scholar 

  15. Pellegrini M, Sebastiani S, Giannaccare G, Campos EC (2019) Intraocular inflammation after Ultrasound Cyclo Plasty for the treatment of glaucoma. Int J Ophthalmol 12(2):338–341

    PubMed  PubMed Central  Google Scholar 

  16. Giannaccare G, Sebastiani S, Campos EC (2018) Ultrasound cyclo plasty in eyes with glaucoma. J Vis Exp 131:e56192

    Google Scholar 

  17. Aptel F, Lafon C (2015) Treatment of glaucoma with high intensity focused ultrasound. Int J Hyperthermia 31(3):292–301

    Article  PubMed  Google Scholar 

  18. Hu D, Tu S, Zuo C, Ge J (2018) Short-term observation of ultrasonic cyclocoagulation in chinese patients with end-stage refractory glaucoma: a retrospective study. J Ophthalmol 2018:4950318

    PubMed  PubMed Central  Google Scholar 

  19. Wang T, Wang R, Su Y, Li N (2021) Ultrasound cyclo plasty for the management of refractory glaucoma in chinese patients: a before-after study. Int Ophthalmol 41(2):549–558

    Article  PubMed  Google Scholar 

  20. Yanagisawa M, Yamashita T, Matsuura M, Fu**o Y, Murata H, Asaoka R (2018) Changes in axial length and progression of visual field damage in glaucoma. Invest Ophthalmol Vis Sci 59(1):407–417

    Article  PubMed  Google Scholar 

  21. Kass MA (1996) Standardizing the measurement of intraocular pressure for clinical research Guidelines from the eye care technology forum. Ophthalmology 103(1):183–185

    Article  CAS  PubMed  Google Scholar 

  22. Thapa SS, Paudyal I, Khanal S, Paudel N, van Rens GH (2011) Comparison of axial lengths in occludable angle and angle-closure glaucoma–the Bhaktapur Glaucoma Study. Optom Vis Sci 88(1):150–154

    Article  PubMed  Google Scholar 

  23. George R, Paul PG, Baskaran M, Ramesh SV, Raju P, Arvind H et al (2003) Ocular biometry in occludable angles and angle closure glaucoma: a population based survey. Br J Ophthalmol 87(4):399–402

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  24. Song P, Wang J, Bucan K, Theodoratou E, Rudan I, Chan KY (2017) National and subnational prevalence and burden of glaucoma in China: a systematic analysis. J Glob Health 7(2):020705

    Article  PubMed  PubMed Central  Google Scholar 

  25. Wei L, He W, Meng J, Qian D, Lu Y, Zhu X (2021) Evaluation of the white-to-white distance in 39,986 chinese cataractous eyes. Invest Ophthalmol Vis Sci 62(1):7

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgements

This study was supported by the National Natural Science Foundation of China under Grant No.81970808 and the Natural Science Foundation of Guangdong Province under Grant Nos.2019A1515011196 and 2020A1515010121.

Funding

The authors have not disclosed any funding.

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to Chengguo Zuo or Mingkai Lin.

Ethics declarations

Conflict of interest

The authors declare that there are no conflicts of interest regarding the publication of this paper.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Zheng, S., Wang, D., Huang, Z. et al. Distribution of ultrasound cyclo plasty probe models in Chinese patients with glaucoma. Int Ophthalmol 43, 4435–4441 (2023). https://doi.org/10.1007/s10792-023-02818-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10792-023-02818-8

Keywords

Navigation