Abstract
Purpose
To investigate the distribution of ultrasound cyclo plasty (UCP) probe models in Chinese patients with glaucoma.
Methods
Patients needing glaucoma surgery were recruited at Zhongshan Ophthalmic Center from January 2019 to December 2019. Patient demographics were recorded and analyzed. Visual acuity, intraocular pressure (IOP), retinal nerve fiber layer (RNFL), mean defect of visual field (MD), ocular axial length (AL) and horizontal corneal diameter (white to white, WTW) of eyes with glaucoma were measured. In addition, the UCP probe models were calculated using a nomogram tool and two ocular anatomical parameters: WTW and AL.
Results
A total of 1281 patients (2000 eyes) were included in the study, including 559 males (43.64%) and 722 females (56.36%). The age of the patients ranged from 18 to 91 years, with a mean age of 61.43 ± 12.21 years. IOP ranged from 22.0 to 60.0 mmHg, with a mean of 26.17 ± 3.52 mmHg. The mean AL and WTW were 22.96 ± 1.43 (ranging from 19.07 to 35.00) and 11.55 ± 0.50 (ranging from 9.6 to 13.7), respectively. According to the results calculated by the nomogram tool, Chinese patients’ eyes mainly adapted to Model 12, with a percentage of 69.05%. Model 13 and Model 11 were suitable for 26.65% and 3.35% of the patients, respectively. A total of 0.95% of Chinese patients did not have a suitable probe model.
Conclusion
For Chinese patients who needed glaucoma surgery, UCP probe models were mainly attributed to Model 12, followed by Model 13, and Model 11 was the least used.
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs10792-023-02818-8/MediaObjects/10792_2023_2818_Fig1_HTML.png)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs10792-023-02818-8/MediaObjects/10792_2023_2818_Fig2_HTML.png)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs10792-023-02818-8/MediaObjects/10792_2023_2818_Fig3_HTML.png)
Similar content being viewed by others
Data availability
The data used to support the findings of this study are available from the corresponding author upon request.
References
Quigley HA, Broman AT (2006) The number of people with glaucoma worldwide in 2010 and 2020. Brit J Ophthalmol 90(3):262–267
Blumberg D, Skaat A, Liebmann JM (2015) Emerging risk factors for glaucoma onset and progression. Prog Brain Res 221:81–101
Benson MT, Nelson ME (1990) Cyclocryotherapy - a Review of Cases over a 10-Year Period. Brit J Ophthalmol 74(2):103–105
Kirwan JF, Shah P, Khaw PT (2002) Diode laser cyclophotocoagulation - Role in the management of refractory pediatric glaucomas. Ophthalmology 109(2):316–323
Mielke J, Schlote T (2004) Subconjunctival anaesthesia using cocaine or mepivacaine for cyclocryotherapy in advanced glaucoma. Klin Monatsbl Augenh 221(1):24–28
Giannaccare G, Sebastiani S, Campos EC (2018) Ultrasound cyclo plasty in eyes with glaucoma. Jove-J Vis Exp 131:e56192
Posarelli C, Covello G, Bendinelli A, Fogagnolo P, Nardi M, Figus M (2019) High-intensity focused ultrasound procedure: The rise of a new noninvasive glaucoma procedure and its possible future applications. Surv Ophthalmol 64(6):826–834
Aptel F, Charrel T, Lafon C, Romano F, Chapelon JY, Blumen-Ohana E et al (2011) Miniaturized high-intensity focused ultrasound device in patients with glaucoma: a clinical pilot study. Invest Ophthalmol Vis Sci 52(12):8747–8753
Denis P, Aptel F, Rouland JF, Nordmann JP, Lachkar Y, Renard JP et al (2015) Cyclocoagulation of the ciliary bodies by high-intensity focused ultrasound: a 12-month multicenter study. Invest Ophthalmol Vis Sci 56(2):1089–1096
Leshno A, Rubinstein Y, Singer R, Sher I, Rotenstreich Y, Melamed S et al (2020) High-intensity focused ultrasound treatment in moderate glaucoma patients: results of a 2-year prospective clinical trial. J Glaucoma 29(7):556–560
Giannaccare G, Pellegrini M, Bernabei F, Urbini L, Bergamini F, Ferro Desideri L et al (2021) A 2-year prospective multicenter study of ultrasound cyclo plasty for glaucoma. Sci Rep 11(1):12647
Figus M, Posarelli C, Nardi M, Stalmans I, Vandewalle E, Melamed S et al (2021) Ultrasound cyclo plasty for treatment of surgery-naive open-angle glaucoma patients: a prospective multicenter 2-year follow-up trial. J Clin Med 10(21):4982
Wang RX, Wang T, Li N (2020) A comparative study between ultrasound cycloplasty and cyclocryotherapy for the treatment of neovascular glaucoma. J Ophthalmol. https://doi.org/10.1155/2020/4016536
Melamed S, Goldenfeld M, Cotlear D, Skaat A, Moroz I (2015) High-intensity focused ultrasound treatment in refractory glaucoma patients: results at 1 year of prospective clinical study. Eur J Ophthalmol 25(6):483–489
Pellegrini M, Sebastiani S, Giannaccare G, Campos EC (2019) Intraocular inflammation after Ultrasound Cyclo Plasty for the treatment of glaucoma. Int J Ophthalmol 12(2):338–341
Giannaccare G, Sebastiani S, Campos EC (2018) Ultrasound cyclo plasty in eyes with glaucoma. J Vis Exp 131:e56192
Aptel F, Lafon C (2015) Treatment of glaucoma with high intensity focused ultrasound. Int J Hyperthermia 31(3):292–301
Hu D, Tu S, Zuo C, Ge J (2018) Short-term observation of ultrasonic cyclocoagulation in chinese patients with end-stage refractory glaucoma: a retrospective study. J Ophthalmol 2018:4950318
Wang T, Wang R, Su Y, Li N (2021) Ultrasound cyclo plasty for the management of refractory glaucoma in chinese patients: a before-after study. Int Ophthalmol 41(2):549–558
Yanagisawa M, Yamashita T, Matsuura M, Fu**o Y, Murata H, Asaoka R (2018) Changes in axial length and progression of visual field damage in glaucoma. Invest Ophthalmol Vis Sci 59(1):407–417
Kass MA (1996) Standardizing the measurement of intraocular pressure for clinical research Guidelines from the eye care technology forum. Ophthalmology 103(1):183–185
Thapa SS, Paudyal I, Khanal S, Paudel N, van Rens GH (2011) Comparison of axial lengths in occludable angle and angle-closure glaucoma–the Bhaktapur Glaucoma Study. Optom Vis Sci 88(1):150–154
George R, Paul PG, Baskaran M, Ramesh SV, Raju P, Arvind H et al (2003) Ocular biometry in occludable angles and angle closure glaucoma: a population based survey. Br J Ophthalmol 87(4):399–402
Song P, Wang J, Bucan K, Theodoratou E, Rudan I, Chan KY (2017) National and subnational prevalence and burden of glaucoma in China: a systematic analysis. J Glob Health 7(2):020705
Wei L, He W, Meng J, Qian D, Lu Y, Zhu X (2021) Evaluation of the white-to-white distance in 39,986 chinese cataractous eyes. Invest Ophthalmol Vis Sci 62(1):7
Acknowledgements
This study was supported by the National Natural Science Foundation of China under Grant No.81970808 and the Natural Science Foundation of Guangdong Province under Grant Nos.2019A1515011196 and 2020A1515010121.
Funding
The authors have not disclosed any funding.
Author information
Authors and Affiliations
Corresponding authors
Ethics declarations
Conflict of interest
The authors declare that there are no conflicts of interest regarding the publication of this paper.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Zheng, S., Wang, D., Huang, Z. et al. Distribution of ultrasound cyclo plasty probe models in Chinese patients with glaucoma. Int Ophthalmol 43, 4435–4441 (2023). https://doi.org/10.1007/s10792-023-02818-8
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10792-023-02818-8