A new, scalable process for microfabrication of a silicone-based, elastic multi-electrode array (MEA) is presented. The device is constructed by spinning poly(dimethylsiloxane) (PDMS) silicone elastomer onto a glass slide, depositing and patterning gold to construct wires and electrodes, spinning on a second PDMS layer, and then micropatterning the second PDMS layer to expose electrode contacts. The micropatterning of PDMS involves a custom reactive ion etch (RIE) process that preserves the underlying gold thin film. Once completed, the device can be removed from the glass slide for conformal interfacing with neural tissue. Prototype MEAs feature electrodes smaller than those known to be reported on silicone substrate (60 μm diameter exposed electrode area) and were capable of selectively stimulating the surface of the in vitro isolated spinal cord of the juvenile rat. Stretchable serpentine traces were also incorporated into the functional PDMS-based MEA, and their implementation and testing is described.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
EUR 32.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or Ebook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price includes VAT (Germany)

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10

Similar content being viewed by others

References

  • D. Armani, C. Liu, N. Aluru. in Micro Electro Mechanical Systems, 1999. MEMS '99. Twelfth IEEE International Conference on. 1999, p. 222

  • A. Branner, R.B. Stein, R.A. Normann, J. Neurophysiol. 85, 1585 (2001)

    Google Scholar 

  • G.S. Brindley, C.E. Polkey, D.N. Rushton, Paraplegia 20, 365 (1982)

    Google Scholar 

  • H.L. Cater, D. Gitterman, S.M. Davis, C.D. Benham, B. Morrison 3rd, L.E. Sundstrom, J. Neurochem. 101, 434 (2007)

    Article  Google Scholar 

  • J.K. Chapin, Curr. Opin. Neurol. 13, 671 (2000)

    Article  Google Scholar 

  • G.M. Clark, Y.C. Tong, R. Black, I.C. Forster, J.F. Patrick, D.J. Dewhurst, J. Laryngol. Otol. 91, 935 (1977)

    Google Scholar 

  • A.F. DiMarco, J. Rehabil. Res. Dev. 38, 601 (2001)

    Google Scholar 

  • D.J. Edell, V.V. Toi, V.M. McNeil, L.D. Clark, IEEE Trans. Biomed. Eng. 39, 635 (1992)

    Article  Google Scholar 

  • J. Garra, T. Long, J. Currie, T. Schneider, R. White, M. Paranjape, J. Vac. Sci. Technol. A Vac. Surf. Films 20, 975 (2002)

    Article  Google Scholar 

  • Y.P. Gerasimenko, I.A. Lavrov, G. Courtine, R.M. Ichiyama, C.J. Dy, H. Zhong, R.R. Roy, V.R. Edgerton, J. Neurosci. Methods 157, 253 (2006)

    Article  Google Scholar 

  • D.S. Gray, J. Tien, C.S. Chen, Adv. Mater. 16, 393 (2004).

    Article  Google Scholar 

  • W.M. Grill, M.D. Craggs, R.D. Foreman, C.L. Ludlow, J.L. Buller, J. Rehabil. Res. Dev. 38, 641 (2001)

    Google Scholar 

  • W. He, R.V. Bellamkonda, Biomaterials 26, 2983 (2005)

    Article  Google Scholar 

  • M.O. Heuschkel, M. Fejtl, M. Raggenbass, D. Bertrand, P. Renaud, J. Neurosci. Methods 114, 135 (2002)

    Article  Google Scholar 

  • T. Hillman, A.N. Badi, R.A. Normann, T. Kertesz, C. Shelton, Otol. Neurotol. 24, 764 (2003)

    Article  Google Scholar 

  • Y.H. Holman G., R.C.W., A.O.D. Willows, D. Denton, K.F. Bohringer, in IEEE-EMBS Second Annual International Special Topic Conference on Microtechnologies in Medicine & Biology, Madison, WI, USA (2002)

  • R.M. Ichiyama, Y.P. Gerasimenko, H. Zhong, R.R. Roy, V.R. Edgerton, Neurosci. Lett. 383, 339 (2005)

    Article  Google Scholar 

  • D.K. Kessler, Ann. Otol. Rhinol. Laryngol. Suppl. 177, 8 (1999)

    Google Scholar 

  • G.H. Kraft, S.S. Fitts, M.C. Hammond, Arch. Phys. Med. Rehabil. 73, 220 (1992)

    Google Scholar 

  • A. Kralj, T. Bajd, R. Turk, Clin. Orthop. Relat. Res. 233, 34 (1988)

    Google Scholar 

  • D.K. Leventhal, D.M. Durand, Ann. Biomed. Eng. 31, 643 (2003)

    Article  Google Scholar 

  • D.K. Leventhal, D.M. Durand, IEEE Trans. Biomed. Eng. 51, 1649 (2004)

    Article  Google Scholar 

  • W.T. Liberson, H.J. Holmquest, D. Scot, M. Dow, Arch. Phys. Med. Rehabil. 42, 101 (1961)

    Google Scholar 

  • G.E. Loeb, R.A. Peck, J. Neurosci. Methods 64, 95 (1996)

    Article  Google Scholar 

  • M.J. Madou, Fundamentals of Microfabrication: The Science of Miniaturization, 2nd edn. (CRC, 2002)

  • M. Maghribi, J. Hamilton, D. Polla, K. Rose, T. Wilson, P. Krulevitch, in Microtechnologies in Medicine & Biology 2nd Annual International IEEE-EMB Special Topic Conference on, Madison, WI, ed. by A. Dittmar, D. Beebe (IEEE, Piscataway, 2002), p. 80

    Chapter  Google Scholar 

  • D.S. Magnuson, T.C. Trinder, J. Neurophysiol. 77, 200 (1997)

    Google Scholar 

  • D.S. Magnuson, M.J. Schramm, J.N. MacLean, Neurosci. Lett. 192, 97 (1995)

    Article  Google Scholar 

  • D. McDonnall, G.A. Clark, R.A. Normann, IEEE Trans. Neural Syst. Rehabil. Eng. 12, 208 (2004)

    Article  Google Scholar 

  • G.G. Naples, J.T. Mortimer, A. Scheiner, J.D. Sweeney, IEEE Trans. Biomed. Eng. 35, 905 (1988)

    Article  Google Scholar 

  • H. Oka, K. Shimono, R. Ogawa, H. Sugihara, M. Taketani, J. Neurosci. Methods 93, 61 (1999)

    Article  Google Scholar 

  • V.S. Polikov, P.A. Tresco, W.M. Reichert, J. Neurosci. Methods 148, 1 (2005).

    Article  Google Scholar 

  • A. Prochazka, M. Gauthier, M. Wieler, Z. Kenwell, Arch. Phys. Med. Rehabil. 78, 608 (1997)

    Article  Google Scholar 

  • A. Prochazka, V.K. Mushahwar, D.B. McCreery, J. Physiol. 533, 99 (2001)

    Article  Google Scholar 

  • D.C. Rodger, W. Li, A.J. Fong, H. Ameri, E. Meng, J.W. Burdick, R.R. Roy, V.R. Edgerton, J.D. Weiland, M.S. Humayun, Y. Tai, in IEEE Engineering in Medicine and Biology Society Special Topic Conference on Microtechnologies in Medicine and Biology, Okinawa, Japan 2006

  • P.J. Rousche, D.S. Pellinen, D.P. Pivin Jr., J.C. Williams, R.J. Vetter, D.R. Kipke, IEEE Trans. Biomed. Eng. 48, 361 (2001)

    Article  Google Scholar 

  • M. Sahin, M.A. Haxhiu, D.M. Durand, I.A. Dreshaj, J. Appl. Physiol. 83, 317 (1997)

    Google Scholar 

  • S. Schmidt, K. Horch, R. Normann, J. Biomed. Mater. Res. 27, 1393 (1993).

    Article  Google Scholar 

  • M. Schuettler, T. Stieglitz, 5th Annual International Conference of the International Functional Electrical Stimulation Society, Aalborg, Denmark, 18 2000

  • M. Schuettler, S. Stiess, B.V. King, G.J. Suaning, J. Neural Eng. 2, S121 (2005)

    Article  Google Scholar 

  • J. Shao, E. Miller. Releasing Polydimethylsiloxane (PDMS) Replica Parts From Micromolds, 2007, from http://www.pnl.gov/microproducts/conferences/2004/posters/shao.pdf

  • B.L. Shay, M. Sawchuk, D.W. Machacek, S. Hochman, J. Neurophysiol. 94, 2867 (2005)

    Article  Google Scholar 

  • F.A. Spelman, IEEE Eng. Med. Biol. Mag. 18, 27 (1999)

    Article  Google Scholar 

  • R.B. Stein, V. Mushahwar, Trends Neurosci. 28, 518 (2005)

    Article  Google Scholar 

  • R.B. Stein, K.G. Pearson, J. Theor. Biol. 32, 539 (1971)

    Article  Google Scholar 

  • T. Stieglitz (2001). Catalogue on Available Flexible, Light-weighted Microelectrodes, from www.ibmt.fraunhofer.de/gruppe_l/download/IBMT_Neuro%20Electrode%20Catalogue%20-%20July%202001.pdf

  • J.J. Struijk, M. Thomsen, J.O. Larsen, T. Sinkjaer, IEEE Eng. Med. Biol. Mag. 18, 91 (1999)

    Article  Google Scholar 

  • G.L. Subrebost, A.J. Rosenbloom, V. Weedn, K. Gabriel, in Proceedings of the Sixth International Symposium on Micro Total Analysis System (mTAS 2002), Nara, Japan, Nov. 2–8, 2002

  • Y.Y.-C.T. Suzuki, in Micro Electro Mechanical Systems, IEEE The Sixteenth Annual International Conference on, Kyoto 2003

  • P.N. Taylor, J.H. Burridge, A.L. Dunkerley, A. Lamb, D.E. Wood, J.A. Norton, I.D. Swain, Clin. Rehabil. 13, 439 (1999)

    Article  Google Scholar 

  • C. Tsay, S.P. Lacour, S. Wagner, B. Morrison III, in Sensors, 2005 IEEE2005, p. 1169

  • C. Tsay, O. Graudejus, S. Wagner, S.P. Lacour, B. Morrison III, in MRS Proceedings, Symposium U: Advanced Materials for Neuroprosthetic Interfaces, San Francisco, CA 2007

  • D.J. Tyler, D.M. Durand, IEEE Trans. Neural Syst. Rehabil. Eng. 10, 294 (2002)

    Article  Google Scholar 

  • H.P. Weingarden, G. Zeilig, R. Heruti, Y. Shemesh, A. Ohry, A. Dar, D. Katz, R. Nathan, A. Smith, Am. J. Phys. Med. Rehabil. 77, 276 (1998)

    Article  Google Scholar 

  • X. Yang, C. Grosjean, Y.C. Tai, in Solid-state Sensor and Actuator Workshop, 1998

  • Z. Yu, O. Graudejus, C. Tsay, S.P. Lacour, S. Wagner, B. Morrison III, in MRS Proceedings, Symposium U: Advanced Materials for Neuroprosthetic Interfaces, 2007

  • Y. Zhong, X. Yu, R. Gilbert, R.V. Bellamkonda, J. Rehabil. Res. Dev. 38, 627 (2001)

    Google Scholar 

Download references

Acknowledgements

We thank James Ross for discussions regarding fabrication strategies, Bao To for machining and assembling initial versions of the clam** connector., J.Mark Meacham for illustration software help, and Jevin Scrivens, Edgar Brown, and Shane Migliore for advice about building and using the strain tester. This work was supported by NIH Grant EB00786-01, NSF IBN-0349042, and NIH Grant EB006179.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Stephen P. DeWeerth.

Additional information

KWM and RJG contributed equally to the work reported in this manuscript.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Meacham, K.W., Giuly, R.J., Guo, L. et al. A lithographically-patterned, elastic multi-electrode array for surface stimulation of the spinal cord. Biomed Microdevices 10, 259–269 (2008). https://doi.org/10.1007/s10544-007-9132-9

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10544-007-9132-9

Keywords

Navigation