Proficiency testing (PT) scheme for the mass fraction of arsenic (As), cadmium (Cd), copper (Cu), nickel (Ni) and zinc (Zn) in bottled drinking water matrices was conducted based on ISO/IEC 17043. The aim of the PT scheme was to evaluate laboratory capability in measuring minerals and contaminants in drinking water to comply with the implementation of Indonesian National Standard SNI 3553:2015 and the Regulation of Indonesia Minister of Health No. 492/2010. The PT material was a candidate of reference material, the homogeneity and stability testing on the material was performed and evaluated according to ISO 13528 and ISO Guide 35, and the material found sufficiently homogenous and stable during the transportation condition and PT period. Metrologically traceable reference values were used as the PT assigned values which were obtained using a high accuracy method, isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS) and gravimetric standard addition (GSA) with internal standard ICP-MS. The performance of the participants was evaluated mainly against the reference value based on z-scores and ζ-scores which is meaningful for assessing participants’ ability in measurement capabilities and measurement uncertainty evaluation. The PT results according to z-scores showed that more than 80 % of total 22 participants obtained satisfactory performance for Cu, Ni and Zn, while only 47 % and 58 % for As and Cd. The differences between the reference values and the robust mean of participants for As (21 %) and Cd (68 %) were found significant in the scheme which shown a big variability of measurement capability of Indonesian testing laboratories in this fields. Unsatisfactory performance of laboratories within their claimed uncertainty based on ζ-scores evaluation means that the laboratories may not assess accurately their measurement uncertainty. Therefore, re-assessment of their uncertainty estimation is needed, and the laboratories are encouraged to improve their capability in the measurement uncertainty for further enhancement.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Data availability

No datasets were generated or analysed during the current study.

References

  1. Birke M, Reimann C, Demetriades A, Rauch U, Lorenz H, Harazim B, Glatte W (2010) Determination of major and trace elements in European bottled mineral water—analytical methods. J Geochem Explor 107(3):217–226. https://doi.org/10.1016/j.gexplo.2010.05.005

    Article  CAS  Google Scholar 

  2. Guidelines for drinking-water quality: fourth edition incorperating the first addendum (2017) World Health Organization, Geneva

  3. Puspita T, Dharmayanti I, Tjandrarini DH, Zahra Z, Anwar A, Irianto J, Rachmat B, Yunianto A (2023) Packaged drinking water in Indonesia: the determinants of household in the selection and management process. J Water Sanit Hyg Dev 13(7):508–519. https://doi.org/10.2166/washdev.2023.050

    Article  Google Scholar 

  4. Indonesian National Standard-SNI 3553 (2015) Mineral water. Badan Standardisasi Nasional, Jakarta, Indonesia

  5. Indonesian Ministry of Health, Regulation No. 492 (2010) Quality requirements of drinking water. Ministry of Health, Jakarta, Indonesia

  6. ISO/IEC 17025 (2017) General requirements for the competency of testing and calibration laboratories. International Standards Organization, Geneva

    Google Scholar 

  7. Cheow PS, Teo TL, Lu T, Gui EM, Lee TK (2020) An accuracy-based proficiency testing programme with metrological reference values for the mass fraction of acesulfame potassium and sucralose in cake mix flour. Accred Qual Assur 25:355–366. https://doi.org/10.1007/s00769-020-01449-1

    Article  CAS  Google Scholar 

  8. Jarvis B (2014) Proficiency testing schemes—a European perspective in encyclopedia of food microbiology, 2nd edn. Elsevier, Amsterdam

    Google Scholar 

  9. ISO/IEC 17043 (2023) Conformity assessment—general requirements for the competence of proficiency testing providers. International Standards Organization, Geneva

    Google Scholar 

  10. Ketrin R, Handayani EM, Komalasari I, Elishian C (2015) First Indonesian proficiency testing scheme using reference values for cadmium, copper, and iron in drinking water. Acrred Qual Assur 20:281–285. https://doi.org/10.1007/s00769-015-1137-0

    Article  CAS  Google Scholar 

  11. ISO 13528 (2022) Statistical methods for use in proficiency testing by interlaboratory comparisons. International Standards Organization, Geneva

    Google Scholar 

  12. ISO Guide 35 (2017) Reference materials-guidance for characterization and assessment of homogeneity and stability. International Standards Organization, Geneva

    Google Scholar 

  13. Heumann KG, Sargent M, Harte R, Harrington C (eds) (2003) Guidelines for achieving high accuracy in isotope dilution mass spectrometry. Wiley, Hoboken

    Google Scholar 

  14. Linsinger T (2010) Comparison of a measurement results with the certified values. European Reference Materials Application Note 1

  15. Grinberg P et al (2024) Final report for SIM.QM-S12: supplementary comparison for trace elements in natural water. Metrologia 61:08002. https://doi.org/10.1088/0026-1394/61/1A/08002

    Article  Google Scholar 

  16. Brookman B, Mann I (eds) (2021) Eurachem guide: selection, use and interpretation of proficiency testing (PT) schemes, 3rd edn. Available from www.eurachem.org

  17. Kim SH, Cho H, Heo SW, Hwang E (2023) APMP-APLAC joint proficiency testing programs for elemental analysis in food with metrological reference values: assessment of participants’ performance considering measurement uncertainties. Talanta 255:124184. https://doi.org/10.1016/j.talanta.2022.124184

    Article  CAS  PubMed  Google Scholar 

  18. Sin DW, Wong YC (2015) Use of assigned reference values: revisiting a small-scale inter-laboratory comparison for residual pesticides in tea. Accred Qual Assur 20:495–500. https://doi.org/10.1007/s00769-015-1157-9

    Article  CAS  Google Scholar 

Download references

Acknowledgements

This work was supported by National Standardization Agency (BSN). The authors gratefully acknowledge all team supporting the SNSU BSN PT scheme and The Physikalisch-Technische Bundesanstalt (PTB) for the funding to attend the 10th Eurachem PT Workshop.

Author information

Authors and Affiliations

Authors

Contributions

C.E.: Planning and conception, Data evaluation, Supervision, Performed characterization and measurement, Wrote and revised the manuscript. E.M.: Wrote and revised the manuscript, Performed measurement and data collection. I.K.: Wrote the manuscript, Prepared sample and performed measurement. E.R.: Wrote the manuscript, visualization, and performed measurement. M.O.: Performed measurement. All authors reviewed and edited the manuscripts.

Corresponding author

Correspondence to Christine Elishian.

Ethics declarations

Competing interests

The authors declare no competing interests.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Elishian, C., Handayani, E.M., Komalasari, I. et al. Indonesian experience in providing accuracy-based proficiency testing scheme using metrologically traceable reference values for elements mass fraction in drinking water. Accred Qual Assur (2024). https://doi.org/10.1007/s00769-024-01599-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s00769-024-01599-6

Keywords

Navigation